MAX5006 MAXIM [Maxim Integrated Products], MAX5006 Datasheet
MAX5006
Related parts for MAX5006
MAX5006 Summary of contents
Page 1
... These devices also include an active-low manual reset input. The MAX5005 features an open-drain reset output, the MAX5006 features an active-low push-pull reset output, and the MAX5007 features an active-high push-pull reset output. Each device is available in a space-saving 10-pin µMAX package. ...
Page 2
USB LDO Regulators with ±15kV TVS and µP Reset ABSOLUTE MAXIMUM RATINGS IN to GND .................................................................-0.3V to +6V D GND..........................................................-0. GND ..............................................-0. RESET, RESET to GND, Push-Pull............-0. RESET to ...
Page 3
... SELR Input Current ENR Input Voltage ENR Input Current Open-Drain RESET Output Low Voltage (MAX5005) Open-Drain Reset Output Leakage Current (MAX5005) Push-Pull RESET Output Voltage (MAX5006) Push-Pull RESET Output Voltage (MAX5007) USB OPTIONS AND TRANSIENT SUPPRESSION D+/D- R Impedance TERM D+/D- Input Leakage Current ...
Page 4
USB LDO Regulators with ±15kV TVS and µP Reset (V = +5V 2.2µF, unless otherwise noted.) OUT IN OUT GROUND-PIN CURRENT vs. SUPPLY VOLTAGE 27.0 26.5 26.0 25.5 25 150mA OUT 24.5 ...
Page 5
USB LDO Regulators with ±15kV TVS (V = +5V 2.2µF, unless otherwise noted.) IN OUT OUT TURN-ON/TURN-OFF RESPONSE MAX5005-7 toc08 V IN 5V/div V OUT 5V/div RESET 5V/div 50ms/div LOAD-TRANSIENT ...
Page 6
... ENR high or a reset disables the termination resistor connection. Active-Low Reset Output. RESET remains low while V RESET is held low. RESET remains low for the duration of the reset timeout period after the reset conditions are terminated. (MAX5005/MAX5006 ONLY) 7 Active-High Reset Output. RESET remains high while V RESET is held low ...
Page 7
... GND SELR ENR The reset supervisor circuit is fully integrated in the MAX5005/MAX5006/MAX5007, and uses the same ref- erence voltage as the regulator. Two supply tolerance reset thresholds, typically -7.5% and -12.5%, are avail- able for each type of device. 7.5% reset: Reset does not assert until the regulator output voltage is at least -3 ...
Page 8
... IC’s junction temperature decreases by 20°C, resulting in a pulsed output during continuous thermal overload conditions. Thermal overload protec- tion is designed to protect the MAX5005/MAX5006/ MAX5007 in the event of fault conditions. For continu- ous operation, do not exceed the absolute maximum junction temperature rating of T Operating Region and Power Dissipation The MAX5005/MAX5006/MAX5007’ ...
Page 9
... Figure 3. Figures 4, 5, and 6 show the actual surge current I/V characteristics with various capacitive loads. The MAX5005/MAX5006/MAX5007 are characterized to the following limits on D+, D-, and IN: • ±15kV using the Human Body Model • ±8kV using the Contact Discharge Method specified in IEC 1000-4-2 (EN61000-4-2) • ...
Page 10
USB LDO Regulators with ±15kV TVS and µP Reset JENNINGS RELAY 80 H 200k 20 RF3D-26S HIGH VOLTAGE D+/ 4kV TVS DEVICE UNDER TEST Figure 2. Surge Current Test Circut OUT 10 D+ ...
Page 11
USB LDO Regulators with ±15kV TVS 1500 CHARGE-CURRENT DISCHARGE RESISTANCE LIMIT RESISTOR HIGH STORAGE VOLTAGE 100pF CAPACITOR DC SOURCE Figure 7. Human Body ESD Test Model 10M SCOPE V ...
Page 12
USB LDO Regulators with ±15kV TVS and µP Reset GND OUT 5 200ns PULSE WIDTH VOLTAGE (V) Figure ...
Page 13
USB LDO Regulators with ±15kV TVS (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information go to www.maxim-ic.com/packages ÿ 0.50±0.1 0.6±0.1 1 0.6±0.1 TOP VIEW D2 ...