MAX5024 MAXIM [Maxim Integrated Products], MAX5024 Datasheet - Page 6

no-image

MAX5024

Manufacturer Part Number
MAX5024
Description
65V, Low-Quiescent-Current, High-Voltage Linear Regulators with ?P Reset and Watchdog Timer
Manufacturer
MAXIM [Maxim Integrated Products]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX5024ESA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX5024LASA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX5024LASA+
Manufacturer:
Maxim
Quantity:
100
Part Number:
MAX5024LASA+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
Company:
Part Number:
MAX5024LASA+T
Quantity:
171
Part Number:
MAX5024MASA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX5024MASA+T
Manufacturer:
MAXIM
Quantity:
4 300
Part Number:
MAX5024SASA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX5024SASA+T
Manufacturer:
AVX
Quantity:
40 000
Part Number:
MAX5024TASA+T
Manufacturer:
TELEDYNE
Quantity:
6 224
Company:
Part Number:
MAX5024TASA+T
Quantity:
2 062
65V, Low-Quiescent-Current, High-Voltage Linear
Regulators with µP Reset and Watchdog Timer
(V
6
MAX5023
IN
_______________________________________________________________________________________
= +14V, C
1
2
3
4
5
6
7
8
PIN
MAX5024
30
25
20
15
10
5
0
IN
47
= 10µF, C
1
2
3
4
5
6
8
7
GROUND-CURRENT DISTRIBUTION
48
51
52
53
OUT
RESET
(T
NAME
HOLD
GND
OUT
N.C.
54
WDI
SET
A
EN
I
IN
GND
= +40°C)
55
= 15µF, V
(µA)
56 57
58
Regulator Input. Supply voltage ranges from +6.5V to +65V. Bypass with a 10µF capacitor to
GND.
Enable Input. Force EN high to turn on the regulator. Pull EN low and force HOLD high (or
open circuit) to place the device in shutdown mode. Internally connected to ground through a
5MΩ resistor.
Ground. GND also functions as a heatsink. Solder to large pads or the circuit-board ground
plane to maximize thermal dissipation.
Active-Low Open-Drain Reset Output. RESET remains low while V
threshold or when WDI is not pulsed within 1.6s. RESET remains low for the duration of the
reset timeout period after the reset conditions are terminated.
Regulator Hold Input. When HOLD is forced low, the regulator stores the on state of the
output allowing the regulator to function even if EN is pulled low. To shutdown the regulator,
release HOLD after EN is pulled low. If HOLD is unused, either float HOLD or connect to OUT.
Internally connected to OUT through a 4µA pullup current source (see Table 1, Truth Table).
No Connection. Not internally connected.
Watchdog Timer Input (MAX5023 only). The watchdog timer asserts a reset if WDI does not
transition within the 1.6s watchdog timeout period. WDI cannot be disabled.
Regulator Output. Fixed (+3.3V or +5V) or adjustable (+2.5V to +11V). Bypass with a 15µF
capacitor (min).
Feedback Input for Setting the Output Voltage. Connect to GND to set the output voltage to
the preset fixed value (+3.3V or +5V). Connect to an external resistor-divider network for
adjustable output operation (MAX5024 only).
59
EN
60 61
= +2.4V, V
80
Typical Operating Characteristics (continued)
OUT
= +5V, SET = GND, T
FUNCTION
30
25
20
15
10
A
5
0
= +25°C, unless otherwise specified.)
45
GROUND-CURRENT DISTRIBUTION
53
56
57
58
(T
A
59
I
GND
= +125°C)
60
(µA)
61 62
OUT
Pin Description
63
is below the reset
64
65 89

Related parts for MAX5024