SAFC130.000MA1G0X MURATA [Murata Manufacturing Co., Ltd.], SAFC130.000MA1G0X Datasheet - Page 5

no-image

SAFC130.000MA1G0X

Manufacturer Part Number
SAFC130.000MA1G0X
Description
CERAMIC MICROWAVE FILTERS SAW FILTERS
Manufacturer
MURATA [Murata Manufacturing Co., Ltd.]
Datasheet
CERAMIC MICROWAVE FILTERS
SAW FILTERS
ENVIRONMENTAL SPECIFICATIONS
MECHANICAL
ENVIRONMENTAL
ELECTRICAL
354
Terminal Strength
Solderability
Random Drop
Vibration
Salt Spray
Temperature Cycling
Humidity
Operating Humidity
Thermal Shock
Life Test (High)
Life Test (Low)
Operating Life Test
Sulfuration
Resistance to
Soldering Heat
Dielectric Withstanding
Voltage
Insulation Resistance
Temperature
Characteristics
TEST ITEM
TEST ITEM
TEST ITEM
PACKAGE
PACKAGE
PACKAGE
LEADED
LEADED
LEADED
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
SMD
SMD
SMD
Filter is soldered onto the center of PCB which is laid on two small supporters
spaced 90mm apart. The PCB is deflected to 1mm below the horizontal level by the
pressing stick for 1 second and repeated 5 times.
A force of 1.0 Kg shall be applied to each terminal in the direction of the axis of
terminal for 30 ± 5 seconds.
A force of 250 gf is applied to each lead in axial direction. The lead shall be bent
90 degrees to one direction, then in opposite direction and returned to the
original position.
Lead terminals are immersed in methanol with 7 to 10% of rosin flux for about
5 seconds, then immersed in soldering bath at 230 ± 5°C for 5 ± 0.5 seconds.
Drop 3 times on concrete floor from 1.0 meter, (30cm for some products).
Vibration amplitude of 1.5mm at 10-55Hz in each of three mutually
perpendicular directions for 1 hour.
Hold in chamber with 5% salt density at 35°C +1.1°/–1.7°C for 48 hours.
Measure after exposure to room condition for 1 hour.
Exposure to 5 cycles of –55°C (30 minutes)
(30 minutes)
Hold in chamber with 90 to 95% R.H. at 40 ± 2°C for 100 hours. Test after 2
hours exposure to room conditions.
Hold in chamber with 90 to 95% R.H. at 40 ± 2°C for 100 hours at 6VDC.
Test after 2 hours exposure to room conditions.
Expose to 5 cycles of –55°C (30 minutes)
exposure to room conditions.
Hold in chamber at 85 ± 2°C for 100 hours. Test after exposure to room
conditions for 2 hours.
Hold in chamber at –30 ± 2°C for 100 hours. Test after exposure to room
conditions for 2 hours.
Hold in chamber at 85 ± 2°C for 100 hours at 6VDC. Test after exposure to room
conditions for 2 hours.
Hold in chamber with 1000ppm sulfur density for 24 hours. Test after exposure
to room conditions for 2 hours.
Filter shall be preheated at 150 ± 20°C for 60 seconds, immersed whole
electrode in soldering bath at 240 ± 5°C for 3 ± 1 seconds, then measured after
exposure to room conditions for 2 hours.
Lead terminals are immersed up to 1.5mm from package base in soldering bath
at 260 ± 5°C for 10 ± 1 seconds, then measured after exposure to room
conditions for 2 hours.
Apply 100VDC between I/O terminals and ground terminal, for 1 minute.
Apply 100VDC between I/O terminals and ground terminal, for 1 minute.
Filter shall be measured between –10°C to +60°C temperature range.
Filter shall be measured between –10°C to +50°C temperature range.
+25°C (15 minutes). Test after 2 hours exposure to room conditions.
TEST CONDITIONS
TEST CONDITIONS
TEST CONDITIONS
+85°C (30 minutes). Test after 2 hours
+25°C (15 minutes), ±85°C
SAF Series
TEST METHOD
TEST METHOD
TEST METHOD
MIL-STD-202E
MIL-STD-201E
MIL-STD-202E
MIL-STD-202E
MIL-STD-202E
MIL-STD-202E
MIL-STD-202E
MIL-STD-202E
MIL-STD-202E
MIL-STD-202E
MIL-STD-202E
MIL-STD-202E
Method 101D
Method 102A
Method 107D
Method 208C
Method 201A
Method 103B
Method 108A
Method 108A
Method 210A
Method 302
CG01-I

Related parts for SAFC130.000MA1G0X