MAX8586ETA MAXIM [Maxim Integrated Products], MAX8586ETA Datasheet
MAX8586ETA
Available stocks
Related parts for MAX8586ETA
MAX8586ETA Summary of contents
Page 1
... Built-In 20ms Fault Blanking Compliant with All USB Specifications 2.75V to 5.5V Input Supply Range FAULT Indicator Output 15kV ESD Protection (with Caps) UL Listing Pending Tiny 8-Pin 3mm x 3mm TDFN Package PART Applications MAX8586ETA INPUT SUPPLY 2.75V TO 5.5V OUTPUT FAULT INDICATOR ON/OFF POLARITY SELECTION ...
Page 2
Single 1.2A USB Switch in 3mm x 3mm TDFN ABSOLUTE MAXIMUM RATINGS IN, ON, SEL, OUT, FAULT, ISET, ENRESET to GND ..-0. OUT.....................................................................-6V to +6V FAULT Sink Current ............................................................20mA Continuous Power Dissipation 8-Pin 3mm x 3mm ...
Page 3
ELECTRICAL CHARACTERISTICS (continued 5V SEL ENRESET Typical values are +25°C, unless otherwise specified. Note 1) A PARAMETER Turn-On Delay Output Rise Time Turn-Off Delay from ON ...
Page 4
Single 1.2A USB Switch in 3mm x 3mm TDFN (Typical Application Circuit QUIESCENT SUPPLY CURRENT vs. SUPPLY VOLTAGE ...
Page 5
Application Circuit FAULT-BLANKING TIME vs. TEMPERATURE -40 - TEMPERATURE (°C) OVERLOAD RESPONSE INTO 2Ω FAULT OUT FAULT ...
Page 6
Single 1.2A USB Switch in 3mm x 3mm TDFN (Typical Application Circuit SWITCH TURN-OFF WAVEFORM INTO 5Ω LOAD MAX8586 toc17 V OUT V ON 1ms/div STARTUP INTO 470µF FAULT V IN AC-COUPLED I ...
Page 7
PIN NAME ON Polarity Selector Input. Drive SEL high to select ON for an active-high enable. Drive SEL to GND to select 1 SEL ON for an active-low enable. Current-Limit Programming Input. Connect a resistor from ISET to GND to ...
Page 8
Single 1.2A USB Switch in 3mm x 3mm TDFN Detailed Description Current-Limit Protection The MAX8586 uses two methods to protect the circuit from overcurrent conditions. Continuous current limiting has tighter accuracy but slower response time com- pared to short-circuit limiting. ...
Page 9
Thermal Shutdown When the MAX8586 die temperature exceeds +160°C, the switch turns off and FAULT goes low. Thermal shut- down does not utilize the 20ms fault-blanking timeout period. When the junction temperature cools by 15°C, the switch turns on again ...
Page 10
Single 1.2A USB Switch in 3mm x 3mm TDFN INPUT SUPPLY 2.75V TO 5.5V R1 OUTPUT 100kΩ FAULT INDICATOR ON/OFF POLARITY SELECTION CONTROL/ ON/OFF Figure 1. Typical Application Circuit Because the package power dissipation is 1951mW, the MAX8586 die temperature ...
Page 11
For the latest package outline information go to www.maxim-ic.com/packages.) PIN 1 INDEX AREA COMMON DIMENSIONS MIN. SYMBOL A 0.70 D 2.90 E 2.90 A1 0.00 L ...