HCS360_11 MICROCHIP [Microchip Technology], HCS360_11 Datasheet - Page 7

no-image

HCS360_11

Manufacturer Part Number
HCS360_11
Description
Manufacturer
MICROCHIP [Microchip Technology]
Datasheet
3.5
The Configuration Word is a 16-bit word stored in
EEPROM array that is used by the device to store
information used during the encryption process, as well
as the status of option configurations. Further
explanations of each of the bits are described in the
following sections.
TABLE 3-2:
3.5.1
MOD selects between Manchester code modulation
and PWM modulation.
If MOD = 1, Manchester modulation is selected:
If MOD = 0, PWM modulation is selected.
3.5.2
BSEL 1 and BSEL 0 determine the baud rate according
to Table 3-3 when PWM modulation is selected.
TABLE 3-3:
© 2011 Microchip Technology Inc.
Bit Number Symbol
MOD
0
0
0
0
10
12
13
14
15
11
0
1
2
3
4
5
6
7
8
9
CONFIG
(Configuration Word)
BSEL 1 BSEL 0
MOD: MODULATION FORMAT
BSEL 1, 0
BAUD RATE SELECTION
0
0
1
1
LNGRD
BSEL 0
BSEL 1
NU
SEED
DELM
TIMO
IND
USRA0
USRA1
USRB0
USRB1
XSER
TMPSD
MOD
OVR
CONFIGURATION WORD.
BAUD RATE SELECTION
0
1
0
1
Long Guard Time
Baud Rate Selection
Baud Rate Selection
Not Used
Seed Transmission enable
Delay mode enable
Time-out enable
Independent mode enable
User bit
User bit
User bit
User bit
Extended serial number
enable
Temporary seed transmis-
sion enable
Manchester/PWM modula-
tion selection
Overflow bit
Bit Description
400
200
200
100
T
E
Unit
us
us
us
us
BSEL 1 and BSEL 0 determine the baud rate according
to Table 3-4 when Manchester modulation is selected.
TABLE 3-4:
3.5.3
The overflow bit is used to extend the number of possi-
ble synchronization values. The synchronization coun-
ter is 16 bits in length, yielding 65,536 values before the
cycle repeats. Under typical use of 10 operations a day,
this will provide nearly 18 years of use before a
repeated value will be used. Should the system
designer conclude that is not adequate, then the over-
flow bit can be utilized to extend the number of unique
values. This can be done by programming OVR to 1 at
the time of production. The encoder will automatically
clear OVR the first time that the transmitted synchroni-
zation value wraps from 0xFFFF to 0x0000. Once
cleared, OVR cannot be set again, thereby creating a
permanent record of the counter overflow. This pre-
vents fast cycling of 64K counter. If the decoder system
is programmed to track the overflow bits, then the effec-
tive number of unique synchronization values can be
extended to 128K. If programmed to zero, the system
will be compatible with old encoder devices.
3.5.4
LNGRD = 1 selects the encoder to extend the guard
time between code words adding ≈ 50 ms. This can be
used to reduce the average power transmitted over a
100 ms window and thereby transmit a higher peak
power.
MOD
1
1
1
1
BSEL 1 BSEL 0
OVR: OVERFLOW
LNGRD: LONG GUARD TIME
0
0
1
1
BAUD RATE SELECTION
0
1
0
1
HCS360
800
400
400
200
T
E
DS40152F-page 7
Unit
us
us
us
us

Related parts for HCS360_11