RT9703CS RICHTEK [Richtek Technology Corporation], RT9703CS Datasheet - Page 13

no-image

RT9703CS

Manufacturer Part Number
RT9703CS
Description
80m?, 3A Smart Universal Power Switch with Flag
Manufacturer
RICHTEK [Richtek Technology Corporation]
Datasheet
Fault Flag Filtering (Optional)
The transient inrush current to downstream capacitance
may cause a short-duration error flag, which may cause
erroneous over-current reporting. A simple 1ms RC low-
pass filter (10k
short-duration transients.
PCB Layout
In order to meet the voltage drop, droop, and EMI
requirements, careful PCB layout is necessary. The
following guidelines must be considered:
Keep all input and output traces as short as possible
and use at least 150-mil, 2 ounce copper for all races.
Avoid vias as much as possible. If vias are necessary,
make them as large as feasible.
Place a ground plane under all circuitry to lower both
resistance and inductance and improve DC and transient
performance (Use a separate ground and power plans
if possible).
Locate the bypass capacitors as close as possible to
the input and output pin of the RT9703.
and 0.1 F) in the flag line eliminates
Preliminary
13
9287
)/*
,3
Board Layout
RT9703
*1'
9,1
&(
*1'
*1'

Related parts for RT9703CS