EL2009CT Elantec, EL2009CT Datasheet
EL2009CT
Available stocks
Related parts for EL2009CT
EL2009CT Summary of contents
Page 1
... There- fore the tab may be mounted to an external heat sink or the chassis without an insulator The EL2009CT is specified for operation over the temperature range and is provided in a 5-lead TO-220 plastic power package ...
Page 2
... All parameters having Min Max specifications are guaranteed The Test Level column indicates the specific device testing actually performed during production and Quality inspection Elantec performs most electrical tests using modern high-speed automatic test equipment specifically the LTX77 Series system Unless otherwise noted all tests are pulsed tests therefore T ...
Page 3
Electrical Characteristics V S Parameter Description V V Supply Sensitivity (Note 5) SR Slew Rate 1 (Note 6) SR Slew Rate 2 (Note Rise Fall Time Bandwidth b ...
Page 4
EL2009C 90 MHz 1 Amp Buffer Amplifier Applications Information ever the current it sources into the load ap- proaches zero In those cases where differential gain and phase are measurably affected resistor R2 may be added to ensure that the ...
Page 5
EL2009 Macromodel Connections input a l Vsupply Vsupply output subckt M2009 Input Stage ...
Page 6
6 ...
Page 7
7 ...
Page 8
... Package Outline General Disclaimer Specifications contained in this data sheet are in effect as of the publication date shown Elantec Inc reserves the right to make changes in the circuitry or specifications contained herein at any time without notice Elantec Inc assumes no responsibility for the use of any circuits described herein and makes no representations that they are free from patent infringement ...