INPUT
OUTPUT
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
OTHERS
ISOLATION
ENVIRONMENT STORAGE TEMP.
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
OTHERS
SPECIFICATIONS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*1
*2
*3
*4 Derating is required.Consult us for details.
*
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail.
A sound may occur from power supply at pulse loading.
R
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
POWER FACTOR
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p] 0 to +50C
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT -RC
INPUT-FG
OUTPUT-RC-AUX-FG
OUTPUT-RC -AUX
OPERATING TEMP. , HUMID.AND ALTITUDE -20 to +71C , 20 - 90%RH ( Non condensing ) 3 , 000m ( 10 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
, HUMID.AND ALTITUDE
PBA300F
Unit type
-20 to +50C
ACIN 100V 3typ
ACIN 200V 1.6typ
ACIN 100V 68typ
ACIN 200V 71typ
ACIN 100V 0.98typ (Io=100%)
ACIN 200V 0.95typ (Io=100%)
ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
ACIN 100V 60
ACIN 200V
0 to +50C
-20 - 0C
-20 - 0C
0 to +50C
ACIN 200V
ACIN 100V 3.3V 60A
* 1
* 1
*3
*3
* 1
* 1
* 1
* 1
*2
-20 to +75C , 20 - 90%RH ( Non condensing ) 3 , 000m ( 10 , 000feet ) max
4.3 - 6.3
60max
3.3V 60A
80max
120max
PBA300F-3R3 PBA300F-5
198
PBA300F-3R3 PBA300F-5
AC85 - 264 1f or DC120 - 350 ( AC50 or DC70 optionally available *4 )
50/60 (47 - 63)
0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1)
3.3
60
20max
40max
140max
160max
40max
12max
300typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100/200V, Io=100%)
3.30 - 3.40
Provided
Provided
AC3 , 000V 1minute , Cutoff current = 10mA , DC500V 50MWmin ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 10mA , DC500V 50MWmin ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA , DC500V 50MWmin ( At Room Temperature )
AC100V 1minute , Cutoff current = 100mA , DC100V 50MWmin ( At Room Temperature )
Forced cooling (internal fan)
LED (Green)
19.6m/s
196.1m/s
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input)
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
102X42X170mm ( without terminal block and screw ) ( WXHXD ) /1.0kg max
2
2
(2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
(20G), 11ms, once each X, Y and Z axis
300
5V 60A
6.5 - 8.0
5V 60A
4.1typ
2typ
74typ
77typ
5
60
60
20max
40max
80max
140max
120max
160max
50max
75max
20max
3.96 - 6.00
5.00 - 5.15
PBA300F-7R5 PBA300F-12
300
7.5V 40A
PBA300F-7R5 PBA300F-12
76typ
79typ
7.5
40
40
36max
60max
120max
160max
150max
180max
75max
120max
30max
5.25 - 8.25
7.50 - 7.80
7.5V 40A
9.0 - 11.6
1
PBA 300
Ordering information
14.4 - 18.6
12V 27A
78typ
81typ
12
27
27
48max
100max
120max
160max
150max
180max
120max
180max
48max
8.25 - 13.20
12.00 - 12.48
324
12V 27A
2
PBA300F-15
330
15V 22A
PBA300F-15
78typ
81typ
15
22
22
60max
120max
120max
160max
150max
180max
150max
180max
60max
10.50 - 16.50
18.0 - 23.3
15V 22A
15.00 - 15.60
3
F
16.50 - 26.40
24V 14(16.5)A 36V 9A
PBA300F-24
79typ
82typ
24
14
14(16.5)
96max
150max
120max
160max
150max
180max
240max
290max
96max
24.00 - 24.96
PBA300F-24
336
24V 14A
28.8 - 37.2
4
-5
25.20 - 39.60
PBA300F-36
324
36V 9A
36.00 - 37.44
43.2 - 54.0
PBA300F-36
81typ
84typ
36
9
9
144max
150max
150max
160max
200max
240max
360max
440max
144max
1Series name
2 Output wattage
3 Universal input
4 Output voltage
5 Optional
Refer to instruction manual
7.1
C :with Coating
G :Low leakage current
U :Operation stop voltage
F3 :Reverse air exhaust
F4 :Low speed fan
5
-O
is set at a lower value
type
38.40 - 56.00
PBA300F-48
79typ
82typ
48
7
192max
300max
150max
400max
200max
500max
480max
600max
192max
48.00 - 49.92
PBA300F-48
336
48V 7A
48V 7A
7
57.6 - 80.0