SX1231 SEMTECH [Semtech Corporation], SX1231 Datasheet - Page 69

no-image

SX1231

Manufacturer Part Number
SX1231
Description
Low Power Integrated UHF Transceiver
Manufacturer
SEMTECH [Semtech Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1231HIMLTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
SX1231HIMLTRT
0
Company:
Part Number:
SX1231HIMLTRT
Quantity:
24 000
Part Number:
SX1231IMLTRT
Manufacturer:
ATMEL
Quantity:
1 200
Part Number:
SX1231IMLTRT
Manufacturer:
SEMTECHCORPORATION
Quantity:
20 000
Part Number:
SX1231ITSTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
SX1231MLTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
6.6. Packet Engine Registers
Table 26 Packet Engine Registers
Rev 2 - Nov 2009
Name
(Address)
RegPreambleMsb
(0x2c)
RegPreambleLsb
(0x2d)
RegSyncConfig
(0x2e)
RegSyncValue1
(0x2f)
RegSyncValue2
(0x30)
RegSyncValue3
(0x31)
RegSyncValue4
(0x32)
RegSyncValue5
(0x33)
RegSyncValue6
(0x34)
RegSyncValue7
(0x35)
RegSyncValue8
(0x36)
ADVANCED COMMUNICATIONS & SENSING
Bits Variable Name
7-0 PreambleSize(15:8)
7-0 PreambleSize(7:0)
5-3 SyncSize
2-0 SyncTol
7-0 SyncValue(63:56)
7-0 SyncValue(55:48)
7-0 SyncValue(47:40)
7-0 SyncValue(39:32)
7-0 SyncValue(31:24)
7-0 SyncValue(23:16)
7-0 SyncValue(15:8)
7-0 SyncValue(7:0)
7
6
SyncOn
FifoFillCondition
Mode
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Page 69
Default
Value
0x00
0x03
0x00
0x01
0x01
0x01
0x01
0x01
0x01
0x01
011
000
1
0
*
*
*
*
*
*
*
Description
Size of the preamble to be sent (from TxStartCondition
fulfilled). (MSB byte)
Size of the preamble to be sent (from TxStartCondition
fulfilled). (LSB byte)
Enables the Sync word generation and detection:
0
1
FIFO filling condition:
0
1
Size of the Sync word:
( SyncSize + 1) bytes
Number of tolerated errors in Sync word
1
Used if SyncOn is set.
2
Used if SyncOn is set and (SyncSize +1) >= 2.
3
Used if SyncOn is set and (SyncSize +1) >= 3.
4
Used if SyncOn is set and (SyncSize +1) >= 4.
5
Used if SyncOn is set and (SyncSize +1) >= 5.
6
Used if SyncOn is set and (SyncSize +1) >= 6.
7
Used if SyncOn is set and (SyncSize +1) >= 7.
8
Used if SyncOn is set and (SyncSize +1) = 8.
st
nd
rd
th
th
th
th
th
byte of Sync word. (MSB byte)
byte of Sync word.
byte of Sync word.
byte of Sync word.
byte of Sync word.
byte of Sync word.
byte of Sync word.
byte of Sync word
Off
On
if SyncAddress interrupt occurs
as long as FifoFillCondition is set
DATASHEET
www.semtech.com
SX1231

Related parts for SX1231