LPT40-M ASTEC [Astec America, Inc], LPT40-M Datasheet

no-image

LPT40-M

Manufacturer Part Number
LPT40-M
Description
40 Watts
Manufacturer
ASTEC [Astec America, Inc]
Datasheet
Special Features
• Universal input
• 3" x 5" footprint
• Less than 1U high
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable 5V output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety
V V D D E E
U U L L
C C S S A A
C C E E M M a a r r k k (LVD)
LPT40-M Series
40 Watts
Total Power:
Input Voltage:
# of Outputs:
0750/EN60601-1 (IEC601)
113769
UL2601 E182560
CSA 22.2 No.601.1
LR109492
40 - 55 Watts
85 - 264 VAC
120 - 300VDC
Triple
Electrical Specifications
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI
Safety ground
leakage current
Output
Maximum Power
Cross regulation
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Remote sense
85-264 VAC
120-300 VDC
47-440 Hz
<18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
1A max. (RMS) @ 115VAC
70% typical at full load (60% for LPT41)
FCC Class A conducted; CISPR 22 Class A conducted
EN55022 Class A conducted;
VDE 0878 PT3 Class A conducted
<75 μA @ 50/60 Hz, 264 VAC input
40W for convection; 55W with 30CFW forced air
±2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 40W load, 115 VAC nominal line
Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
RoHS
Embedded Power for
Business-Critical Continuity
LPT40-M Series
Rev. 04.13.06
1 of 3

Related parts for LPT40-M

LPT40-M Summary of contents

Page 1

... Overload protection protected @ 110% to 145% above peak rating 5.7 to 6.7 VDC on the main output Overvoltage protection LPT41: 3.6 to 4.6VDC Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 04.13.06 LPT40-M Series RoHS ...

Page 2

... ±2% 2.5A 4A ±5% 0.7A 1A ± ±2% 2.5A 3A ±5% 0.7A 1A ±5% 27.5W 20W Embedded Power for Business-Critical Continuity 50mV 120mV 120mV 50mV 150mV 150mV Rev. 04.13.06 LPT40 Series ...

Page 3

... PINS: 08-58-0111 Molex 09-50-8061 (USA) 09-91-0600 (UK) PINS: 08-58-0111 PINS: 08-52-0114 Embedded Power for Business-Critical Continuity Rev. 04.13.06 LPT40-M Series Astec Power 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Technical Support: +1 888 41 ASTEC ...

Related keywords