AME40-MAZ_1 AIMTEC [AIMTEC], AME40-MAZ_1 Datasheet

no-image

AME40-MAZ_1

Manufacturer Part Number
AME40-MAZ_1
Description
40 Watt | AC-DC Converter
Manufacturer
AIMTEC [AIMTEC]
Datasheet
Models
Single output
Models
Dual output
Input Specifications
Output Specifications
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
AME40-3.3SMAZ
AME40-5SMAZ
AME40-12SMAZ
AME40-15SMAZ
AME40-24SMAZ
AME40-5DMAZ
AME40-12DMAZ
AME40-15DMAZ
AME40-24DMAZ
Current
Inrush current <2ms
Leakage current
External fuse
Input dissipation
Start-up time
Voltage accuracy
Line regulation
Load regulation
Cross regulation
Maximum Capacitive load
Transient response deviation
Ripple & Noise*
Hold-up time (min)
Minimum Load Current
www.aimtec.com
F 052e R8.D
Model
Model
Parameters
Parameters
Input Voltage
Input Voltage
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-260/47-440
(VAC/Hz)
(VAC/Hz)
25% load - 1
FEATURES:
• 4000VAC I/O isolation
• Medical Switching power modules for PCB mounting
• Operating temperature: -40 to +85°C
• Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC
Recommended slow blow type
Depending of the model
0-100% load single
20MHz bandwidth
No load; 115VAC
No load; 264VAC
0-100% load dual
25% load Step
st
Conditions
Conditions
out, 100% load – 2
115 VAC
230 VAC
115 VAC
230 VAC
115VAC
(LL-HL)
Input Voltage
Input Voltage
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
120-370
(VDC)
(VDC)
Tel: +1 514 620 2722
1 of 3
nd
out
Output Voltage
Output Voltage
(V)
(V)
3.3
±12
±15
±24
12
15
24
470-23 000
±5
5
Typical
Typical
3.15
<0.5
<0.8
±0.5
117
±2
±1
±2
±5
±2
50
29
0
Output Current
Output Current
Series AME40-MAZ
±0.835
3.33
2.66
1.66
40 Watt | AC-DC Converter
±1.66
±1.33
max
max
8
8
(A)
(A)
±4
Maximum
Maximum
150
1000
530
25
50
Toll free: + 1 888 9 AIMTEC
Energy star compliant
RoHS compliant
Low Ripple and Noise
CE, cULus approvals
Efficiency
Efficiency
North America only
% of Vout
% of Max
(%)
(%)
mV p-p
78
82
84
83
82
80
85
82
77
Units
Units
mA
mA
ms
ms
(924 6832)
µA
µF
W
%
%
%
%
A
A
A
CB

Related parts for AME40-MAZ_1

AME40-MAZ_1 Summary of contents

Page 1

... Depending of the model 25% load Step 20MHz bandwidth 115VAC Tel: +1 514 620 2722 Series AME40-MAZ 40 Watt | AC-DC Converter • Energy star compliant • RoHS compliant • Low Ripple and Noise • CE, cULus approvals Output Current ...

Page 2

... IEC/EN 61000-3-2, (EN60555-2) EN55011, class B IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 Tel: +1 514 620 2722 Series AME40-MAZ 40 Watt | AC-DC Converter Rated 4000 Typical Maximum 47 110 Zener diode clamp Auto recovery -40 - +85 -40 to +95 ...

Page 3

... Tel: +1 514 620 2722 Series AME40-MAZ 40 Watt | AC-DC Converter NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. labels shown, including safety agency certifications on labels, may vary 3 ...

Related keywords