ICX204 SONY [Sony Corporation], ICX204 Datasheet - Page 13

no-image

ICX204

Manufacturer Part Number
ICX204
Description
Diagonal 6mm (Type 1/3) Progressive Scan CCD Image Sensor with Square Pixel for Color Cameras
Manufacturer
SONY [Sony Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICX204
Manufacturer:
SANYO
Quantity:
100 000
Part Number:
ICX204AL
Manufacturer:
MITSUBISHI
Quantity:
100
4. Video signal shading
5. Uniformity between video signal channels
6. Dark signal
7. Dark signal shading
8. Line crawl
9. Lag
Set to standard imaging condition III. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity
so that the average value of the Gr signal output is 150mV. Then measure the maximum (Grmax [mV]) and
minimum (Grmin [mV]) values of the Gr signal output and substitute the values into the following formula.
SHg = (Grmax – Grmin)/150
After measuring 4, measure the maximum (Rmax [mV]) and minimum (Rmin [mV]) values of the R signal
and the maximum (Bmax [mV]) and minimum (Bmin [mV]) values of the B signal, and substitute the values
into the following formulas.
∆Srg = (Rmax – Rmin)/150
∆Sbg = (Bmax – Bmin)/150
Measure the average value of the signal output (Vdt [mV]) with the device ambient temperature 60°C and
the device in the light-obstructed state, using the horizontal idle transfer level as a reference.
After measuring 6, measure the maximum (Vdmax [mV]) and minimum (Vdmin [mV]) values of the dark
signal output and substitute the values into the following formula.
∆Vdt = Vdmax – Vdmin [mV]
Set to standard imaging condition II. Adjusting the luminous intensity so that the average value of the Gr
signal output is 150mV, and then insert R, G and B filters and measure the difference between G signal
lines (∆Glr, ∆Glg, ∆Glb [mV]) as well as the average value of the G signal output (Gar, Gag, Gab).
Substitute the values into the following formula.
Lci = ∆Gli/Gai
Adjust the Gr signal output value generated by strobe light to 150mV. After setting the strobe light so that it
strobes with the following timing, measure the residual signal (Vlag). Substitute the value into the following
formula.
Lag = (Vlag/150)
Strobe light
100 [%] (i = r, g, b)
Output
timing
100 [%]
V2A
VD
100 [%]
100 [%]
100 [%]
Light
Gr signal output 150mV
– 13 –
Vlag (lag)
ICX204AK

Related parts for ICX204