Specifications of TS4274CM25 RN

Rohs
yes
Parameter
Absolute Maximum Rating
Input Supply Voltage
Operation Input Supply Voltage
Power Dissipation
Junction Temperature Range
Operating Temperature Range
Storage Temperature Range
General Description
The TS4274 series of fixed-voltage monolithic micro-power voltage regulators is designed for a wide range of
applications. This device excellent choice of use in battery-power application. Furthermore, the quiescent current
increases on slightly at dropout, which prolongs battery life.
This series of fixed-voltage regulators features very low ground current (200uA Typ.) and very low drop output voltage
(600mV at 400mA). This includes a tight initial tolerance of 2% typ., and very low output temperature coefficient.
Features
Block Diagram
Dropout voltage typically 0.6V @Io=400mA
Output current up to 400mA
Output voltage trimmed before assembly
Load dump protection
Internal current limit
Thermal shutdown protection
TO-220
(D
TO-263
2
PAK)
400mA Ultra Low Dropout Fixed Voltage Regulator
(DPAK)
TO-252
1/10
Symbol
Note: Where xx denotes voltage option, available are
Ordering Information
TS4274CZxx C0
TS4274CMxx RN
TS4274CPxx RO
TS4274CWxx RP
V
T
T
V
P
T
OPR
OPR
STG
IN
D
J
Part No.
12= 12V
50= 5.0V
33= 3.3V
25= 2.5V
18= 1.8V
SOT-223
Internally Limited
-65 ~ +150
-40 ~ + 85
-18 ~ +35
Limit
Package
+150
SOT-223
Pin Definition:
1. Input
2. Ground
3. Output
TO-220
TO-263
TO-252
26
2.5Kpcs / 13” Reel
2.5Kpcs / 13” Reel
800pcs / 13” Reel
50pcs / Tube
TS4274
Packing
Version: A07
Unit
o
o
o
W
V
V
C
C
C

Related parts for TS4274CM25 RN

TS4274CM25 RN Summary of contents

Page 1

TO-220 TO-263 2 (D PAK) General Description The TS4274 series of fixed-voltage monolithic micro-power voltage regulators is designed for a wide range of applications. This device excellent choice of use in battery-power application. Furthermore, the quiescent current increases on slightly ...

Page 2

Electrical Characteristics ( V Parameter Output Voltage Input Supply Voltage Output Voltage Temperature Coefficient Line Regulation Load Regulation Dropout Voltage (Note 4) Quiescent Current (Note 5) Short Circuit Current (Note 6) Output Noise, 10Hz to 100KHz, I =10mA L Power ...

Page 3

Application Information The TS4274 series is a high performance with low dropout voltage regulator suitable for moderate to high current and voltage regulator application. Its 600mV(typ) dropout voltage at full load and over temperature makes it especially valuable in battery ...

Page 4

Application Information (Continue) Thermal Characteristics A heatsink may be required depending on the maximum power dissipation and maximum ambient temperature of the application. Under all possible operating conditions, the junction temperature must be within the range specified under absolute maximum ...

Page 5

Application Information (Continue) 2 Figure 1 – D PAK Thermal Resistance and Maximum Power Dissipation vs. P.C.B Copper Length Figure 2 – DPAK Thermal Resistance and Maximum Power Dissipation vs. P.C.B Copper Length Figure 3 – SOT-223 Thermal Resistance and ...

Page 6

Marking Diagram 400mA Ultra Low Dropout Fixed Voltage Regulator TO-220 Mechanical Drawing DIM Year Code M = Month Code (A=Jan, B=Feb, C=Mar, ...

Page 7

Marking Diagram 400mA Ultra Low Dropout Fixed Voltage Regulator TO-263 Mechanical Drawing DIM Year Code M = Month Code (A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep, ...

Page 8

Marking Diagram 400mA Ultra Low Dropout Fixed Voltage Regulator TO-252 Mechanical Drawing Y = Year Code M = Month Code (A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep, J=Oct, K=Nov, L=Dec Lot Code XX = Voltage Code ...

Page 9

Marking Diagram 400mA Ultra Low Dropout Fixed Voltage Regulator SOT-223 Mechanical Drawing Y = Year Code M = Month Code (A=Jan, B=Feb, C=Mar, D=Apl, E=May, F=Jun, G=Jul, H=Aug, I=Sep, J=Oct, K=Nov, L=Dec Lot Code XX = Voltage Code ...

Page 10

Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Information contained herein is intended to provide a product description only. No ...

Related keywords