ES-R-2101B-M EasySync, ES-R-2101B-M Datasheet

no-image

ES-R-2101B-M

Manufacturer Part Number
ES-R-2101B-M
Description
RS-232 Interface IC RS232 to 1 Prt RS458 /RS485, Metal, Isltd
Manufacturer
EasySync
Datasheet
Use of EasySYNC devices in life support and/or safety applications is entirely at the user’s risk, and the
user agrees to defend, indemnify and hold harmless EasySYNC from any and all damages, claims, suits
or expense resulting from such use.
The EasySYNC ES-R-2001B-M and ES-R-2101B-M are used to convert RS-232 signals to RS-422/RS-
485 signals. The converters provide instant connectivity to RS-422/RS-485 communication devices
for factory automation equipment, multi-drop data collection devices, barcode readers, time clocks,
scales, data entry terminals, PC to PC long distance communications (up to 1.3KM) and serial
communication in harsh environments.
This manual covers the following products:
ES-R-2001B-M
ES-R-2101B-M
Unit 1, 2 Seaward Place, Centurion Business Park, Glasgow, G41 1HH, United Kingdom
E-Mail (Support):
RS-232 to RS-422/RS-485
Tel.: +44 (0) 141 418 0181
Converters Manual
Document Reference No.: ES_000086
Copyright © 2010 - 2011 EasySYNC Limited
support@easysync.co.uk
ES-R-2x01B-M
EasySYNC Ltd
Issue Date: 2011-08-24
Version 1.0
EasySYNC Ltd
Fax: + 44 (0) 141 418 0110
Web:
http://www.easysync.co.uk

Related parts for ES-R-2101B-M

ES-R-2101B-M Summary of contents

Page 1

... RS-232 to RS-422/RS-485 Converters Manual Document Reference No.: ES_000086 The EasySYNC ES-R-2001B-M and ES-R-2101B-M are used to convert RS-232 signals to RS-422/RS- 485 signals. The converters provide instant connectivity to RS-422/RS-485 communication devices for factory automation equipment, multi-drop data collection devices, barcode readers, time clocks, scales, data entry terminals long distance communications ( ...

Page 2

... Introduction ............................................................................................ 3 2 Specification ............................................................................................ 4 3 Features of the ES-R-2x01B-M ................................................................. 5 3.1 Optical Isolation & Surge Protection (ES-R-2101B-M only) ........................... 5 3.2 Power Supply ................................................................................................ 5 3.3 Enclosure ...................................................................................................... 5 3.4 Configuring for RS-422 and RS-485 Modes ................................................... 5 4 Hardware Installation .............................................................................. 6 4.1 General Notes and Warnings ......................................................................... 6 4.2 RS-232 DCE or DTE Pin Assignment .............................................................. 7 Table 1 Jumper settings for RS-232 DCE or DTE Pin Assignment ......................... 7 4 ...

Page 3

... Introduction The EasySYNC ES-R-2001B-M and ES-R-2101B-M are used to convert RS-232 signals to RS-422/RS-485 signals. The converters provide instant connectivity to RS-422/RS-485 communication devices for factory automation equipment, multi-drop data collection devices, barcode readers, time clocks, scales, data entry terminals long distance communications (up to 1.3KM) and serial communication in harsh environments ...

Page 4

... RS-485 data signals (half-duplex) : Data-, Data+, GND LEDs indicate TxD and RxD Wide input power range : 48V DC Opto-isolated RS-232 to RS-422/RS-485 Converter (ES-R-2101B-M) Converts RS-232 port to high speed RS-422 / RS-485 port RS-232 port can be selected to DCE or DTE pin assignment RS-422/RS-485 port is optically isolated with 2000 Volt DC optical isolation ...

Page 5

... ESD. The surge suppression on all signals prevents damage caused by lightning or high voltage. 3.2 Power Supply The ES-R-2001B-M and ES-R-2101B-M accept a wide range of supply voltages, from 48V DC. The power input connector is a 3–pin terminal-block style connector as shown in Figure 1 below. An external switch-mode power adapter is supplied with the converter. Figure 1 3 ...

Page 6

... Before applying the termination, check your cable specification for proper impedance matching. Termination is normally used in the node at each end of the bus, but nodes in the middle of the bus should not have termination enabled. The ES-R-2x01B-M converters have jumpers to allow internal termination resistors to be enabled if required ...

Page 7

... Figure 2 4.3 RS-422 and RS-485 Mode Block Configuration A 3-pin DIP switch is used to set to select the mode of operation. The switches should be set to RS-422 mode or RS-485 mode as per the requirements of your application. The RS-422 & RS-485 Mode Block Configuration Settings are shown in Table 2. RS-422 ...

Page 8

... Inside the converter, there is a 7x3 (21pin) header block which has jumpers to enable the Tx, Rx and CTS 120 Ohm termination resistors, and the Tx and Rx 750 Ohm biasing resistors. Open the case and set the jumpers as per the requirements of your application. The settings are detailed below. ...

Page 9

... Connector Pinout Information This section shows the connector pinouts used on the ES-R-2001B-M and ES-R-2101B-M converters. This allows the use of a straight-through cable between the host computer and the RS-232 port of the ES-R-2x01B-M. 5.1 RS-232 Signal Pin-outs of DB-9 Female (DCE) Pin Number Description 1 DCD = Data Carrier Detect ...

Page 10

... TxD+ = Transmit data, positive polarity 3 RxD+ = Receive data, positive polarity 4 RxD- = Receive data, negative polarity 5 GND = Signal ground 6 RTS- = Request to send, negative polarity 7 RTS+ = Request to send, positive polarity 8 CTS+ = Clear to send , positive polarity 9 CTS- = Clear to send, negative polarity Table 6 5-way Terminal Block The table below shows the RS-422 pin-out of the 5-way terminal block ...

Page 11

... RxD ± and CTS ± inputs, which can be enabled using jumpers. The TxD ± and RTS ± lines which are outputs from the ES-R-2x01B-M are terminated at the receiver at the other end of the bus as shown. Twisted pair wires are required for each signal pair. ...

Page 12

... Data+ = Transmit / Receive Data, positive polarity 5 GND = Signal ground Note: Other terminals have no function in this mode and should be left unconnected. Table 9 ES-R-2x01B-M RS-232 to RS-422/RS-485 Converters Manual RS-485 half-duplex pin-out for DB-9 connector RS-485 half-duplex pin-out for 5-way terminal block ©2010 - 2011 EasySYNC Ltd. Document Reference No.: ES_000086 Version 1 ...

Page 13

... Wiring Diagrams The diagram shows an ES-R-2x01B-M converter connected to an RS-485 half-duplex bus. If the ES-R- 2x01B one end of the bus (as shown), the built-in resistor can be enabled to terminate the Data ± lines. The Tx ± termination jumper is used to enable this resistor. A second termination resistor is fitted at the other end of the bus as shown ...

Page 14

... RxD– = Receive data, negative polarity 5 GND = Signal ground Table 11 Document Reference No.: ES_000086 ES-R-2x01B-M RS-232 to RS-422/RS-485 Converters Manual Transmit data, positive polarity RS-485 full duplex pin-out for DB-9 connector RS-485 full duplex pin-out for terminal block ©2010 - 2011 EasySYNC Ltd. Version 1.0 # Clearance No ...

Page 15

... The following diagram shows an RS-485 full-duplex bus. The ES-R-2x01B-M has a built-in resistor for terminating its RxD ± input, which can be enabled using a jumper. The Tx ± lines which are outputs from the ES-R-2x01B-M would be terminated at the receiver at the other end of the bus as shown. Twisted pair wires are required for each signal pair ...

Page 16

... Fax: +1 (503) 547 0990 E-Mail (Sales) sales@easysync-ltd.com E-Mail (Support) support@easysync-ltd.com E-Mail (General Inquiries) admin@easysync-ltd.com Web Site URL http://easysync-ltd.com Web Shop URL http://easysync-ltd.com Document Reference No.: ES_000086 ES-R-2x01B-M RS-232 to RS-422/RS-485 Converters Manual ©2010 - 2011 EasySYNC Ltd. Version 1.0 # Clearance No ...

Page 17

... EasySYNC. Use of EasySYNC devices in life support and/or safety applications is entirely at the user’s risk, and the user agrees to defend, indemnify and hold harmless EasySYNC from any and all damages, claims, suits or expense resulting from such use. This document is subject to change without notice ...

Page 18

... Appendix A - List of Figures and Tables List of Figures Figure 48V DC power input connector .................................................. 5 Figure 2 Jumpers used to select RS-232 DCE and DTE ........................................... 7 Figure 4 RS-422 4 Wire Full Duplex ..................................................................... 11 Figure 5 RS-422 with handshaking signals connected ......................................... 11 Figure 6 RS-485 Half Duplex Wiring ..................................................................... 13 Figure 7 RS-485 Full Duplex Wiring ..................................................................... 15 ...

Page 19

... Appendix B - Revision History Version 1.0 First Release Document Reference No.: ES_000086 ES-R-2x01B-M RS-232 to RS-422/RS-485 Converters Manual ©2010 - 2011 EasySYNC Ltd. Version 1.0 # Clearance No August 2011 19 ...

Related keywords