MAX3224EPP Maxim Integrated, MAX3224EPP Datasheet - Page 10

no-image

MAX3224EPP

Manufacturer Part Number
MAX3224EPP
Description
RS-232 Interface IC
Manufacturer
Maxim Integrated
Series
MAX3224, MAX3225, MAX3226, MAX3227, MAX3244, MAX3245r
Datasheet

Specifications of MAX3224EPP

Data Rate
250 Kbps
Operating Supply Voltage
3 V to 5.5 V
Supply Current
1 mA
Operating Temperature Range
0 C to + 70 C
Function
Transceiver
Number Of Drivers
2
Number Of I/os
8
Number Of Receivers
2
Propagation Delay Time Ns
0.15 us
Shutdown
Yes
MAX3224–MAX3227/MAX3244/MAX3245
10
1µA Supply Current, 1Mbps, 3.0V to 5.5V,
RS-232 Transceivers with AutoShutdown Plus
peripheral transmitters are turned off, and the UART dri-
ving the transmitter inputs is inactive. The system turns
on again when a valid transition is applied to any
RS-232 receiver or transmitter input. As a result, the sys-
tem saves power without changes to the existing BIOS
or operating system.
Figures 3a and 3b depict valid and invalid RS-232
receiver voltage levels. INVALID indicates the receiver
input’s condition, and is independent of FORCEON and
FORCEOFF states. Figure 3 and Tables 1 and 2 sum-
marize the operating modes of the MAX3224–
MAX3227/MAX3244/MAX3245 devices. FORCEON and
FORCEOFF override AutoShutdown Plus circuitry.
When neither control is asserted, the IC selects
Figure 3a. INVALID Functional Diagram, INVALID Low
Figure 3b. INVALID Functional Diagram, INVALID High
Table 2. INVALID Truth Table
+2.7V
-2.7V
R_IN
INVALID DEASSERTED IF ANY RECEIVER INPUT HAS BEEN BETWEEN +2.7V AND -2.7V
FOR LESS THAN 30μs.
+0.3V
-0.3V
R_IN
INVALID ASSERTED IF ALL RECEIVER INPUTS ARE BETWEEN +0.3V AND -0.3V FOR
AT LEAST 30μs.
PRESENT AT ANY
RECEIVER INPUT
RS-232 SIGNAL
Yes
No
INVALID OUTPUT
TIMER
30μs
TIMER
30μs
R
R
High
Low
INVALID
INVALID
between these states automatically based on the last
receiver or transmitter input edge received.
When shut down, the device’s charge pumps turn off,
V+ is pulled to V
ter outputs are high impedance, and READY
(MAX3224–MAX3227) is driven low. The time required
to exit shutdown is typically 100µs (Figure 6).
Figure 3c. AutoShutdown Plus Logic
Figure 3d. Power-Down Logic
Figure 4a. Receiver Positive/Negative Thresholds for INVALID
* POWERDOWN IS ONLY AN INTERNAL SIGNAL.
THE TRANSMITTERS AND THE POWER SUPPLIES.
R_IN
IT CONTROLS THE OPERATIONAL STATUS OF
T_IN
AUTOSHDN
FORCEOFF
FORCEON
+2.7V
+0.3V
-0.3V
-2.7V
DETECT
DETECT
EDGE
EDGE
0
CC
FORCEON
, V- is pulled to ground, the transmit-
INDETERMINATE
INDETERMINATE
INVALID HIGH
INVALID HIGH
INVALID LOW
FORCEOFF
TIMER
30sec
S
R
Maxim Integrated
POWERDOWN*
AUTOSHDN

Related parts for MAX3224EPP