MAX6843UKD2+T Maxim Integrated, MAX6843UKD2+T Datasheet - Page 14

no-image

MAX6843UKD2+T

Manufacturer Part Number
MAX6843UKD2+T
Description
Supervisory Circuits NULL
Manufacturer
Maxim Integrated
Series
MAX6841, MAX6842, MAX6843, MAX6844, MAX6845r
Datasheet

Specifications of MAX6843UKD2+T

Number Of Voltages Monitored
1
Monitored Voltage
0.9 V to 1.5 V
Output Type
Active Low, Push-Pull
Manual Reset
Resettable
Watchdog
No Watchdog
Battery Backup Switching
No Backup
Power-up Reset Delay (typ)
0.15 ms
Supply Voltage - Max
1.8 V
Chip Enable Signals
No
Maximum Power Dissipation
571 mW
Power Fail Detection
No
Supply Current (typ)
8.1 uA
Supply Voltage - Min
0.55 V
Dual/Triple Ultra-Low-Voltage SOT23 µP
Supervisory Circuits
Note: The first “_ _” are placeholders for the threshold voltage
levels of the devices. Desired threshold levels are set by the part
number suffix found in the Reset Voltage Threshold Suffix Guide.
The “_” after the D is a placeholder for the reset timeout delay
time. Desired delay time is set using the timeout period suffix
found in the Reset Timeout Period Suffix Guide. For example the
MAX6716UTLTD3-T is a dual-voltage supervisor V
V
Devices are available in both leaded and lead-free packaging.
Specify lead-free by replacing "-T" with "+T" when ordering.
14
MAX6721UT_ _D_ -T
MAX6722UT_ _D_ -T
MAX6723UT_ _D_ -T
MAX6724UT_ _D_ -T
MAX6725KA_ _D_ -T
MAX6726KA_ _D_ -T
MAX6727KA_ _D_ -T
MAX6728KA_ _D_ -T
MAX6729KA_ _D_ -T
TH
Ordering Information (continued)
NUMBER
MAX6715
MAX6716
MAX6717
MAX6718
MAX6719
MAX6720
MAX6721
MAX6722
MAX6723
MAX6724
MAX6725
MAX6726
MAX6727
MAX6728
MAX6729
2 = 3.075V, and 210ms (typ) timeout period.
PART
______________________________________________________________________________________
PART
NUMBER OF
MONITORS
VOLTAGE
2
2
2
2
3
3
2
2
3
3
3
3
3
3
3
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
-40°C to +85°C
TEMP RANGE
RESET
OPEN-
DRAIN
2
1
1
1
1
1
2
1
PIN-PACKAGE
6 SOT23-6
6 SOT23-6
6 SOT23-6
6 SOT23-6
8 SOT23-8
8 SOT23-8
8 SOT23-8
8 SOT23-8
8 SOT23-8
TH
1 = 4.625V,
RESET
OPEN-
DRAIN
1
RESET
PUSH-
PULL
2
1
1
1
1
1
1
RESET
PUSH-
PULL
1
MANUAL
RESET
Selector Guide
WATCH-
INPUT
DOG
√ (open drain)
√ (push-pull)
POWER-
OUTPUT
INPUT/
FAIL

Related parts for MAX6843UKD2+T