MAX6457UKD0C-T Maxim Integrated, MAX6457UKD0C-T Datasheet

no-image

MAX6457UKD0C-T

Manufacturer Part Number
MAX6457UKD0C-T
Description
Supervisory Circuits
Manufacturer
Maxim Integrated
Series
MAX6457, MAX6458, MAX6459, MAX6460r
Datasheet

Specifications of MAX6457UKD0C-T

Number Of Voltages Monitored
1
Monitored Voltage
4 V to 28 V
Undervoltage Threshold
1.071 V
Overvoltage Threshold
1.151 V
Manual Reset
Not Resettable
Watchdog
No Watchdog
Supply Voltage - Max
28 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Package / Case
SOT-23
Maximum Power Dissipation
571 mW
Minimum Operating Temperature
- 40 C
Supply Current (typ)
6.5 uA
Supply Voltage - Min
4 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX6457UKD0C-T
Manufacturer:
MAXIM
Quantity:
20
The MAX6457–MAX6460 high supply voltage, low-power
voltage monitors operate over a 4V to 28V supply voltage
range. Each device includes a precision bandgap refer-
ence, one or two low-offset voltage comparators, internal
threshold hysteresis, power-good or reset timeout
options, and one or two high-voltage open-drain outputs.
Two external resistors (three for window detection) set the
trip threshold voltages.
The MAX6457 is a single voltage monitor for undervoltage
or overvoltage detection. A logic-based clear input either
latches the output for overvoltage applications or allows
the device to operate in transparent mode. The MAX6458
includes two comparators (one overvoltage and one
undervoltage) for window detection and a single output to
indicate if the monitored input is within an adjustable volt-
age window. The MAX6459 includes dual overvoltage/
undervoltage comparators with two independent com-
parator outputs. Use the MAX6459 as a window com-
parator with separate undervoltage and overvoltage
outputs or as two independent, single voltage monitors.
The MAX6460 includes a single comparator and an inter-
nal reference, and can also accept an external reference.
The inverting and noninverting inputs of the comparator
are externally accessible to support positive or negative
voltage monitors and to configure the device for active-
high or active-low output logic.
The MAX6457/MAX6458 offer fixed timing options as a
voltage detector with a 50µs typical delay or as a reset cir-
cuit with a 90ms minimum reset timeout delay. The moni-
tored input must be above the adjusted trip threshold (or
within the adjusted voltage window for the MAX6458) for
the selected timeout period before the output changes
state. The MAX6459/MAX6460 offer only a fixed 50µs
timeout period. Internal threshold hysteresis options (0.5%,
5%, and 8.3% for the MAX6457/MAX6458/MAX6459, and
0.5% for the MAX6460) reduce output chatter in noise-
sensitive applications. Each device is available in a small
SOT23 package and specified over the extended temper-
ature range of -40°C to +125°C.
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maximintegrated.com.
Undervoltage Monitoring/Shutdown
Overvoltage Monitoring/Protection
Window Voltage Detection Circuitry
Multicell Battery-Stack Powered Equipment
Notebooks, eBooks
Automotive
Industrial
Telecom
Networking
General Description
W-CDMA Upconverters and PA Drivers
Applications
o Wide Supply Voltage Range, 4V to 28V
o Internal 2.25V ±2.5% Reference
o Low Current (3.5µA, typ at 12V)
o Open-Drain n-Channel Output (28V Compliant)
o Internal Threshold Hysteresis Options
o Two IN-to-OUT Timeout Period Options
o Internal Undervoltage Lockout
o Immune to Short Voltage Transients
o Small SOT23 Packages
o Few External Components
o Fully Specified from -40°C to +125°C
Note: The MAX6457/MAX6458/MAX6459 are available with
factory-trimmed internal hysteresis options. The MAX6457 and
MAX6458 offer two fixed timing options. Select the desired hys-
teresis and timing options using Table 1 or the Selector Guide at
the end of the data sheet, and enter the corresponding letters
and numbers in the part number by replacing “_ _” or “_”. These
devices are offered in tape-and-reel only and must be ordered in
2500-piece increments.
Devices are available in both leaded and lead(Pb)-free/RoHS-
compliant packaging. Specify lead(Pb)-free by replacing “-T”
with “+T” when ordering.
/V denotes an automotive qualified part.
Pin Configurations appear at end of data sheet.
MAX6457UKD_ _-T
MAX6458UKD_ _-T
MAX6459UT_-T
MAX6459UT_/V+
MAX6460UT-T
(0.5%, 5%, 8.3%)
(50µs, 150ms)
CHARGER
BATTERY
PART
MAX6457–MAX6460
BATTERY
5-CELL
STACK
with Power Control
Li+
+21V (NOMINAL)
Typical Operating Circuit
R1
R2
Ordering Information
IN+
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
TEMP RANGE
GND
MAX6457
V
CC
CLEAR
OUT
19-2048; Rev 6; 12/12
IN
R
PULLUP
Features
PIN-PACKAGE
5 SOT23
5 SOT23
6 SOT23
5 SOT23
6 SOT23
CONVERTER
DC-DC
SHDN
LOAD
OUT

Related parts for MAX6457UKD0C-T

MAX6457UKD0C-T Summary of contents

Page 1

W-CDMA Upconverters and PA Drivers General Description The MAX6457–MAX6460 high supply voltage, low-power voltage monitors operate over 28V supply voltage range. Each device includes a precision bandgap refer- ence, one or two low-offset voltage comparators, internal threshold ...

Page 2

... MAX UNITS 7.5 µA 12.5 1.255 1.255 1.255 1.255 V 1.194 1.194 1.151 1.151 %V TH +55 nA µs 210 ms ms 0.4 V Maxim Integrated ...

Page 3

... Note 3: Startup time is the time required for the internal regulator and reference to reach specified accuracy after the monitor is powered up from GND. Note 4: The open-drain output can be pulled voltage greater than V Maxim Integrated CONDITIONS ≥ 1.5V 250µA, OUT asserted, ...

Page 4

... TRIP THRESHOLD VOLTAGE vs. TEMPERATURE (5% HYSTERESIS) 1.25 1.23 1. 1.19 1.17 1. (FALLING) TH 1.13 1. 110 125 -40 -25 - TEMPERATURE (°C) OUTPUT LOW VOLTAGE vs. OUTPUT SINK CURRENT T = +125° +25° -40° 12V CC 0.01 0 100 I (mA) SINK + (RISING 110 125 Maxim Integrated ...

Page 5

... TEMPERATURE (°C) MAXIMUM TRANSIENT DURATION vs. INPUT OVERDRIVE 300 250 200 150 100 INPUT OVERDRIVE (V Maxim Integrated Typical Operating Characteristics (continued) TIMEOUT PERIOD vs. TEMPERATURE 1000 100 MAX6457UKD3 10 1 MAX6457UKD0 0.1 0.01 -40 -25 - 125 TEMPERATURE (°C) ...

Page 6

... OUT goes high when V is above V IN- IN+ drops below V IN+ TH- . OUTA also goes low for V TH+ CC exceeds V and goes high IN- TH+ . OUTB also goes low when V TH drive CLEAR high to latch OUT high. > and V IN- . IN- and goes between drops Maxim Integrated ...

Page 7

... Figure 1. MAX6457 Functional Diagram V CC IN+ UV IN- OV HYSTERESIS OPTION 1.228V "UV": UNDERVOLTAGE "OV": OVERVOLTAGE GND Figure 3. MAX6459 Functional Diagram Maxim Integrated IN+ IN- LATCH OUT CLEAR Figure 2. MAX6458 Functional Diagram MAX6459 OUTA OUTB Figure 4. MAX6460 Functional Diagram MAX6457–MAX6460 SOT Packages Functional Diagrams ...

Page 8

... V REFD = reference output voltage (2.25V, typ), REF = divided reference desired trip thresh- TRIP V TRIP IN+ REF MAX6460 IN- REFD GND R4 V HYST TH ⎞ ⎟ ⎠ R PULLUP OUT OUT t TP Maxim Integrated ...

Page 9

... Latched-Output Operation The MAX6457 features a digital latch input (CLEAR) to latch any overvoltage event. If the voltage on IN below the internal threshold (V Maxim Integrated Hysteresis Timeout Period Figure 8. Undervoltage Lockout Typical Application Circuit 4V, OUT remains low regardless of the state of CLEAR. ...

Page 10

... CC , OUTA asserts low while OUTB TRIPLOW OUT MAX6458 ONLY R1 IN+ MAX6458 R2 MAX6459 R PULLUP IN- OUTA R3 OUTB MAX6459 ONLY GND LOAD R3 SCR ), TRIPHIGH falls CC R PULLUP OUT PULLUP OUTA OUTB Maxim Integrated ...

Page 11

... CC R1 MAX6457– MAX6460 IN+ (OUTA FOR MAX6459) R2 GND Figure 12. Monitoring Voltages Other than V Maxim Integrated , OUTB TRIPHIGH and TRIPLOW The following is an example for calculating R1, R2, and R3 of Figure 11 for window detection. Select the upper ⎞ and lower trip points (V ⎟ ...

Page 12

... MAX6457–MAX6460 High-Voltage, Low-Current Voltage Monitors in SOT Packages Table 1. Factory-Trimmed Internal Hysteresis and Timeout Period Options PART MAX6457UKD_ _ -T MAX6458UKD_ _ -T MAX6459UT_ -T MAX6460UT-T PIN PART COUNT MAX6457UKD0A-T 5 MAX6457UKD3A-T 5 MAX6457UKD0B-T 5 MAX6457UKD3B-T 5 MAX6457UKD0C-T 5 MAX6457UKD3C-T 5 MAX6458UKD0A-T 5 MAX6458UKD3A-T 5 MAX6458UKD0B-T 5 MAX6458UKD3B-T 5 MAX6458UKD0C-T 5 MAX6458UKD3C-T 5 MAX6459UTA-T 6 MAX6459UTB-T 6 MAX6459UTC-T ...

Page 13

... V MON be within the specified operating range TOP VIEW OUT GND OUTA GND Maxim Integrated The open-drain outputs of the MAX6457–MAX6460 allow the output voltage to be selected independent For systems requiring an output voltage other than CC Ω ...

Page 14

... RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE PACKAGE OUTLINE NO. TYPE CODE 5 SOT23 U5+1 21-0057 6 SOT23 U6+1 21-0058 LAND PATTERN NO. 90-0174 90-0175 Maxim Integrated ...

Page 15

... Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed ...

Related keywords