NAND01GW3B2CN6E NUMONYX, NAND01GW3B2CN6E Datasheet - Page 25

no-image

NAND01GW3B2CN6E

Manufacturer Part Number
NAND01GW3B2CN6E
Description
IC FLASH 1GBIT 48TSOP
Manufacturer
NUMONYX
Datasheets

Specifications of NAND01GW3B2CN6E

Format - Memory
FLASH
Memory Type
FLASH - Nand
Memory Size
1G (128M x 8)
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Cell Type
NAND
Density
1Gb
Access Time (max)
25us
Interface Type
Parallel
Boot Type
Not Required
Address Bus
8b
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
128M
Supply Current
30mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Speed
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NAND01GW3B2CN6E
Manufacturer:
Numonyx
Quantity:
5
Part Number:
NAND01GW3B2CN6E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
NAND01GW3B2CN6E
Quantity:
3 500
Company:
Part Number:
NAND01GW3B2CN6E
Quantity:
3 500
NAND01G-B2B, NAND02G-B2C
6.3
6.3.1
6.3.2
Page program
The page program operation is the standard operation to program data to the memory array.
Generally, the page is programmed sequentially, however the device does support random
input within a page. It is recommended to address pages sequentially within a given block.
The memory array is programmed by page, however partial page programming is allowed
where any number of bytes (1 to 2112) or words (1 to 1056) can be programmed.
The maximum number of consecutive partial page program operations allowed in the same
page is four. After exceeding this a Block Erase command must be issued before any further
program operations can take place in that page.
Sequential input
To input data sequentially the addresses must be sequential and remain in one block.
For sequential input each page program operation consists of five steps (see
1.
2.
3.
4.
5.
Random data input in a page
During a sequential input operation, the next sequential address to be programmed can be
replaced by a random address, by issuing a Random Data Input command. The following
two steps are required to issue the command:
1.
2.
Random Data Input can be repeated as often as required in any given page.
Once the program operation has started the status register can be read using the Read
Status Register command. During program operations the status register will only flag errors
for bits set to '1' that have not been successfully programmed to '0'.
During the program operation, only the Read Status Register and Reset commands will be
accepted, all other commands will be ignored.
Once the program operation has completed the P/E/R controller bit SR6 is set to ‘1’ and the
Ready/Busy signal goes High.
The device remains in read status register mode until another valid command is written to
the command interface.
one bus cycle is required to setup the Page Program (sequential input) command (see
Table
four or five bus cycles are then required to input the program address (refer to
and
the data is then loaded into the data registers
one bus cycle is required to issue the Page Program Confirm command to start the
P/E/R controller. The P/E/R will only start if the data has been loaded in step 3
the P/E/R controller then programs the data into the array.
one bus cycle is required to setup the Random Data Input command (see
two bus cycles are then required to input the new column address (refer to
Table
10)
7)
Device operations
Figure
Table
Table
Table 6
9):
10)
6).
25/61

Related parts for NAND01GW3B2CN6E