AT24C04N-10SC Atmel, AT24C04N-10SC Datasheet - Page 6

IC EEPROM 4KBIT 400KHZ 8SOIC

AT24C04N-10SC

Manufacturer Part Number
AT24C04N-10SC
Description
IC EEPROM 4KBIT 400KHZ 8SOIC
Manufacturer
Atmel
Datasheet

Specifications of AT24C04N-10SC

Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Memory Size
4K (512 x 8)
Speed
400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Package / Case
8-SOIC (3.9mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT24C04N-10SC
Manufacturer:
infineon
Quantity:
28
Part Number:
AT24C04N-10SC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT24C04N-10SC-1.8
Manufacturer:
TOS
Quantity:
2 080
Part Number:
AT24C04N-10SC-1.8
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT24C04N-10SC-2.7
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Device Operation
CLOCK and DATA TRANSITIONS: The SDA pin is normally pulled high with an exter-
nal device. Data on the SDA pin may change only during SCL low time periods (see
Figure 4 on page 7). Data changes during SCL high periods will indicate a start or stop
condition as defined below.
START CONDITION: A high-to-low transition of SDA with SCL high is a start condition
which must precede any other command (see Figure 5 on page 8).
STOP CONDITION: A low-to-high transition of SDA with SCL high is a stop condition.
After a read sequence, the stop command will place the EEPROM in a standby power
mode (see Figure 5 on page 8).
ACKNOWLEDGE: All addresses and data words are serially transmitted to and from the
EEPROM in 8-bit words. The EEPROM sends a zero to acknowledge that it has
received each word. This happens during the ninth clock cycle.
STANDBY MODE: The AT24C01A/02/04/08/16 features a low-power standby mode
which is enabled: (a) upon power-up and (b) after the receipt of the STOP bit and the
completion of any internal operations.
MEMORY RESET: After an interruption in protocol, power loss or system reset, any 2-
wire part can be reset by following these steps:
1. Clock up to 9 cycles.
2. Look for SDA high in each cycle while SCL is high.
3. Create a start condition.
AT24C01A/02/04/08/16
6
0180T–SEEPR–12/04