M29W640FT70N6E NUMONYX, M29W640FT70N6E Datasheet - Page 22

IC FLASH 64MBIT 70NS 48TSOP

M29W640FT70N6E

Manufacturer Part Number
M29W640FT70N6E
Description
IC FLASH 64MBIT 70NS 48TSOP
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29W640FT70N6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
64M (8Mx8, 4Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Supply Voltage Range
2.7V To 3.6V
Memory Case Style
TSOP
No. Of Pins
48
Access Time
70ns
Logic Function Number
29W640
Memory
RoHS Compliant
Memory Configuration
8M X 8, 4M X 16
Interface Type
CFI, Parallel
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5033
497-5033

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W640FT70N6E
Manufacturer:
ST
Quantity:
1 000
Part Number:
M29W640FT70N6E
Manufacturer:
ST
Quantity:
17 280
Part Number:
M29W640FT70N6E
Manufacturer:
ST
0
Part Number:
M29W640FT70N6E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
M29W640FT70N6E
Quantity:
5
4.1.10
22/71
Program command
The Program command can be used to program a value to one address in the memory
array at a time. The command requires four Bus Write operations, the final write operation
latches the address and data, and starts the Program/Erase Controller.
Programming can be suspended and then resumed by issuing a Program Suspend
command and a Program Resume command, respectively (see
Suspend command
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status Register is never read and no error condition is given.
During the program operation the memory will ignore all commands. It is not possible to
issue any command to abort or pause the operation. Typical program times are given in
Table 8: Program, Erase times and Program, Erase Endurance
operations during the program operation will output the Status Register on the Data
Inputs/Outputs. See the section on the Status Register for more details.
After the program operation has completed the memory will return to the Read mode, unless
an error has occurred. When an error occurs the memory will continue to output the Status
Register. A Read/Reset command must be issued to reset the error condition and return to
Read mode.
Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase
Commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’.
and
Section 4.1.9: Program Resume
command).
cycles. Bus Read
Section 4.1.8: Program

Related parts for M29W640FT70N6E