VIPER17LD STMicroelectronics, VIPER17LD Datasheet - Page 17

IC OFFLINE CONV PWM OVP 16SOIC

VIPER17LD

Manufacturer Part Number
VIPER17LD
Description
IC OFFLINE CONV PWM OVP 16SOIC
Manufacturer
STMicroelectronics
Series
VIPer™ plusr
Datasheet

Specifications of VIPER17LD

Output Isolation
Isolated
Frequency Range
54 ~ 66kHz
Voltage - Input
8.5 ~ 23.5 V
Voltage - Output
800V
Power (watts)
12W
Operating Temperature
-40°C ~ 150°C
Package / Case
16-SOIC (0.154", 3.90mm Width) Exposed Pad
Output Voltage
800 V
Output Power
1 W
Input Voltage
- 0.3 V
Switching Frequency
115 KHz
Operating Temperature Range
- 40 C to + 150 C
Mounting Style
SMD/SMT
Duty Cycle (max)
80 %
Number Of Outputs
1
For Use With
497-9052 - BOARD EVAL FOR VIPER17LN497-9050 - BOARD DEMO BASED ON VIPER17HN497-9007 - BOARD EVAL BASED ON VIPER17497-8513 - BOARD EVAL VIPER17HN 6W SMPS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VIPER17LD
Manufacturer:
ST
0
Part Number:
VIPER17LD
Manufacturer:
ST
Quantity:
15 942
Part Number:
VIPER17LD-7LF
Quantity:
1 000
Part Number:
VIPER17LD-7LF
Quantity:
3 775
Part Number:
VIPER17LDTR
Manufacturer:
ST
0
Part Number:
VIPER17LDTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
VIPER17LDTR
0
VIPER17
7.4
7.5
Power down operation
At converter power down, the system loses regulation as soon as the input voltage is so low
that the peak current limitation is reached. The V
the V
energy transfers to the IC interrupted and consequently the V
Figure 23 on page
the start up sequence is inhibited and the power down completed. This feature is useful to
prevent converter’s restart attempts and ensures monotonic output voltage decay during the
system power down.
Auto restart operation
If after a converter power down, the V
is not inhibited and will be activated only when the V
V
generator restarts the V
V
fault condition. After a fault condition, the charging current, I
the 3 mA (typ.) of a normal start up converter phase. This feature together with the low
V
long repetition rate and the converter works safely with extremely low power throughput.
The
Figure 25. Timing diagram: behavior after short circuit
DD(RESTART)
DD(RESTART)
DD(RESTART)
Figure 25
DDoff
threshold (see
. The scenario above described is for instance a power down because of a
threshold (see
threshold ensures that, after a fault, the restart attempts of the IC has a very
shows the IC behavioral after a short circuit event.
16. Later, if the V
DD
Table 7 on page
capacitor charging only when the V
Table 7 on page
Doc ID 14419 Rev 7
IN
IN
is lower than V
is higher than V
6) the power MOSFET is switched OFF, the
6). This means that the HV start up current
DD
voltage drops and when it falls below
DD
DRAIN_START
voltage drops down the
DRAIN_START,
DDch
DD
DD
, is 0.6 mA (typ.) instead of
voltages decreases,
voltage drops below
(see
Operation descriptions
the start up sequence
Table 7 on page