TOP104YAI Power Integrations, TOP104YAI Datasheet - Page 13

IC OFFLINE SWIT PWM OTP HV TO220

TOP104YAI

Manufacturer Part Number
TOP104YAI
Description
IC OFFLINE SWIT PWM OTP HV TO220
Manufacturer
Power Integrations
Series
TOPSwitch®r
Datasheet

Specifications of TOP104YAI

Output Isolation
Isolated
Frequency Range
90 ~ 110kHz
Voltage - Output
350V
Power (watts)
110W
Operating Temperature
-40°C ~ 150°C
Package / Case
TO-220-3
Output Voltage
5.8 V
Input / Supply Voltage (max)
110 VAC
Input / Supply Voltage (min)
100 VAC
Duty Cycle (max)
70 %
Switching Frequency
100 KHz
Supply Current
1.2 mA
Operating Temperature Range
- 40 C to + 150 C
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TOP104YAI
Quantity:
15
Part Number:
TOP104YAI
Quantity:
5 510
Part Number:
TOP104YAI
Manufacturer:
POWER
Quantity:
20 000
Company:
Part Number:
TOP104YAI
Quantity:
7 850
NOTES:
1. For specifications with negative values, a negative temperature coefficient corresponds to an increase in
2. It is possible to start up and operate TOPSwitch at DRAIN voltages well below 36 V. Refer to the "Low Input
3. This section specifies only parameters affected by low input voltage operation (Drain Voltages less than 36 V). All
4. For low input voltage applications, the primary peak current could be set to a lower value than the current limit to
DRAIN Supply
Voltage
CONTROL Pin
Charging Current
Auto-restart
Duty Cycle
Auto-restart
Frequency
LOW INPUT VOLTAGE OPERATION (See Note 3)
13 V.
magnitude with increasing temperature, and a positive temperature coefficient corresponds to a decrease in
magnitude with increasing temperature.
Voltage" Specification section for details.
other parameters remain unchanged.
increase efficiency. Refer to the Output Characteristics graph (Drain Current vs. Drain Voltage). The voltage
across the transformer primary during the ON time is the difference between the input voltage and the drain
voltage (V
For example, if the input voltage is 16 VDC and a TOP104 (3.3A minimum current limit) is used at a primary peak
current of 1A. Then the (V
Specification
DS(ON)
).
Symbol
DS(ON)
) is 3 V at 100 C and the energizing voltage across the transformer primary is
(Unless Otherwise Specified)
T
VS2 = 16 V R1 = 0
j
= 25 C
T
SOURCE = 0 V
See Note 4
Conditions
See Figure 14
j
= -40 to 125 C
S1/Open
S1/Open
V
V
C
C
= 0 V
= 5 V
Min
-2.3
-1.2
16
-1.65
-0.64
Typ
0.85
4
Max
-0.28
TOP100-4
-1
8
mA
mA
Volts
Hz
Units
%
7/ 09
F
13

Related parts for TOP104YAI