DS2745U+ Maxim Integrated Products, DS2745U+ Datasheet - Page 9

IC BATT MONITOR I2C 8-UMAX

DS2745U+

Manufacturer Part Number
DS2745U+
Description
IC BATT MONITOR I2C 8-UMAX
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2745U+

Function
Fuel, Gas Gauge/Monitor
Battery Type
Lithium-Ion (Li-Ion); Nickel-Metal Hydride (NiMH)
Voltage - Supply
2.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-TSSOP, 8-MSOP (0.118", 3.00mm Width)
Product
Fuel Gauges
Operating Supply Voltage
2.5 V to 5.5 V
Supply Current
70 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Charge Safety Timers
No
Mounting Style
SMD/SMT
Temperature Monitoring
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
CURRENT ACCUMULATION
The Accumulated Current register (ACR) serves as an up/down counter holding a running count of charge stored in
the battery. Current measurement results, plus a programmable bias value are internally summed, or accumulated,
at the completion of each current measurement conversion period with the results displayed in the ACR. The ACR
has a range of 0mVh to +409.6mVh with an LSb of 6.25μVh   A dditional registers hold fractional results of each
accumulation, however, these bits are not user accessible. The ACR count clamps at FFFFh when accumulating
charge values and at 0000h when accumulating discharge values.
Read and write access is allowed to the ACR. Whenever the ACR is written, fractional accumulation results are
cleared. A write to the ACR also forces the ADC to measure its offset and update the offset correction factor.
Current measurement and accumulation resume (using the new offset correction) with the second conversion
following the write to the ACR. Figure 7 describes the ACR address, format, and resolution.
Figure 7. ACCUMULATED CURRENT REGISTER FORMAT
Table 4. ACCUMULATED CURRENT RANGE FOR VARIOUS RSNS VALUES
CURRENT OFFSET BIAS
The Current Offset Bias register (COBR) allows a programmable offset value to be added to raw current
measurements. The result of the raw current measurement plus the COBR value is displayed as the current
measurement result in the CURRENT register, and is used for current accumulation. The COBR value can be used
to correct for a static offset error, or can be used to intentionally skew the current results and therefore the current
accumulation.
Read and write access is allowed to COBR. Whenever the COBR is written, the new value is applied to all
subsequent current measurements. COBR can be programmed in 1.56V steps to any value between +198.1V
and -199.7V. The COBR value is stored as a two’s complement value in volatile memory, and must be initialized
via the interface on power-up. Figure 8 describes the COBR address, format, and resolution.
Figure 8. CURRENT OFFSET BIAS REGISTER FORMAT
“S”: sign bit
MSb
409.6mVh
V
2
SS
15
- V
2
SNS
14
2
MSB—Address 10
13
2
20.48Ah
12
20m
2
11
“S”: sign bit
MSb
ACR RANGE
2
S
10
27.31Ah
15m
2
2
9
6
LSb
2
2
8
5
R
SNS
9 of 15
Address 61
2
4
40.96Ah
10m
Units:
MSb
2
2
3
7
2
2
1.56V/Rsns
2
6
81.92Ah
2
2
LSB—Address 11
1
5m
5
DS2745 Low-Cost I
LSb
2
2
0
Units:
4
2
3
6.25Vh/Rsns
2
2
2
2
C Battery Monitor
1
LSb
2
0

Related parts for DS2745U+