IR21571S International Rectifier, IR21571S Datasheet - Page 12

no-image

IR21571S

Manufacturer Part Number
IR21571S
Description
IC BALLAST CONTROL 16-SOIC
Manufacturer
International Rectifier
Type
Ballast Controllerr
Datasheet

Specifications of IR21571S

Frequency
45.5 ~ 50.5 kHz
Current - Supply
5.5mA
Current - Output
500mA
Voltage - Supply
11.4 V ~ 15.6 V
Operating Temperature
-40°C ~ 125°C
Package / Case
16-SOIC (3.9mm Width)
Package
16-lead SOIC Narrow
Circuit
Fluorescent Ballast IC
Offset Voltage (v)
625
Output Source Current Min (ma)
250
Output Sink Current Min (ma)
400
Vcc Range (v)
10-25V with UVLO
Output Voltage Min (v)
10
Output Voltage Max (v)
25
Special Ic
Fully Integrated
Pbf
PbF Option Available
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
*IR21571S

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IR21571S
Manufacturer:
IR
Quantity:
20 000
Company:
Part Number:
IR21571S
Quantity:
55 000
Company:
Part Number:
IR21571S
Quantity:
33
Part Number:
IR21571STR
Manufacturer:
IR
Quantity:
191
Part Number:
IR21571STRPBF
Manufacturer:
IR
Quantity:
20 000
Company:
Part Number:
IR21571STRPBF
Quantity:
9 000
Company:
Part Number:
IR21571STRPBF
Quantity:
25 780
Three leads on the IR21571 are used for protection, as shown in Figure 10 below. These are V
monitor), S
The first of these protection leads senses the voltage
on the DC bus by means of an external resistor
divider and an internal comparator with hysteresis.
When power is first supplied to the IC at system
startup, 3 conditions are required before oscillation
is initiated: 1.) the voltage on the V
the rising undervoltage lockout threshold (11.5V),
2.) the voltage at the V
3.) the voltage on the SD lead must be below
approximately 1.85V. If a low dc bus condition occurs
during normal operation, or if power to the ballast is
shut off, the dc bus will collapse prior to the V
chip (assuming the V
IR21571 (S) & (PbF)
12
Figure 10: Lamp protection & automatic restart circuitry block diagram with external component connection.
Sensing the DC Bus Voltage
+V
D
BUS
(unlatched shutdown), C
R2
R1
R
OC
Lamp Protection & Automatic Restart Circuitry Operation
C1
CPH
VDC
OC
DT
DC
CC
1
2
7
8
lead must exceed 5.1V, and
7.6V
is derived from a charge
7.6V
50uA
3.0V
5.1V
1.0uA
5.1V
4.0V
CC
lead must exceed
VOLTAGE
DETECT
UNDER-
S
S
R
(latched shutdown) and OC (CS+ threshold programming).
Q
Q
CC
of the
from oscillator
Q
Q
section
S
R
DETECT
OVER-
TEMP
pump off of the output of the half-bridge). In this
case, the voltage on the V
off, thereby protecting the power transistors from
potentially hazardous hard switching. Approximately
2V of hysteresis has been designed into the internal
comparator sensing the V
for variations in the dc bus voltage under varying
load conditions. When the dc bus recovers, the chip
restarts from the beginning of the control sequence,
as shown in timing diagram Figure 11.
T
R
Q
Q
Q
Q
CLK
R
D
2.0V
0.2V
7.6V
7.6V
10
9
DC
DC
CS
SD
lead will shut the oscillator
lead, in order to account
R3
Q2
C2
R4
lamp cathode
from lower
R
CS
www.irf.com
R5
V
DC
CC
(dc bus

Related parts for IR21571S