AMIS30622C6227G ON Semiconductor, AMIS30622C6227G Datasheet - Page 23

no-image

AMIS30622C6227G

Manufacturer Part Number
AMIS30622C6227G
Description
IC MOTOR DVR MICROSTP I2C 20SOIC
Manufacturer
ON Semiconductor
Type
Micro Stepping Motor Driverr
Datasheet

Specifications of AMIS30622C6227G

Applications
Stepper Motor Driver
Number Of Outputs
1
Current - Output
800mA
Voltage - Supply
6.5 V ~ 29 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
20-SOIC (7.5mm Width)
Operating Supply Voltage
5 V
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS30622C6227G
Manufacturer:
ON
Quantity:
1 001
Part Number:
AMIS30622C6227G
Manufacturer:
ON Semiconductor
Quantity:
74
Thermal Shutdown Mode
<SoftStop> command and goes to motor shutdown
mode (see Figure 14: State Diagram Temperature
Management).
Temperature Management
thresholds and one shutdown level, as illustrated in the state
When thermal shutdown occurs, the circuit performs a
The AMIS−30622 monitors temperature by means of two
− <Tinfo> = “00”
− <TW> = ‘0’
− <TSD> = ‘0’
− <Tinfo> = “01”
− <TW> = ‘0’
− <TSD> = ‘0’
Normal Temp.
Low Temp.
T° < Tlow
T° > Tlow
T° < Ttw &
I
GetFullStatus1
Figure 14. State Diagram Temperature Management
2
C Frame:
T° > Ttw
T° > Ttw
− <Tinfo> = “10”
− <TW> = ‘1’
− <TSD> = ‘0’
− <Tinfo> = “00”
− <TW> = ‘1’
− <TSD> = ‘0’
− <Tinfo> = “00”
− <TW> = ‘1’
− <TSD> = ‘1’
− Motor shutdown
Thermal warning
http://onsemi.com
(motion disabled)
Post thermal
Post thermal
shutdown 2
warning
23
T° < Ttw
diagram and illustration of Figure 14: State Diagram
Temperature Management below. The only condition to
reset flags <TW> and <TSD> (respectively thermal warning
and thermal shutdown) is to be at a temperature lower than
Ttw and to get the occurrence of a GetFullStatus1 I
frame.
T° < Ttw
T° > Ttsd
T° > Ttw
T° > Ttsd
− <Tinfo> = “11”
− <TW> = ‘1’
− <TSD> = ‘1’
−SoftStop if
− Motor shutdown
− <Tinfo> = “10”
− <TW> = ‘1’
− <TSD> = ‘1’
− Motor shutdown
Thermal shutdown
motion ongoing
(motion disabled)
(motion disabled)
Post thermal
shutdown 1
T° < Ttsd
2
C

Related parts for AMIS30622C6227G