MAX6695AUB+ Maxim Integrated Products, MAX6695AUB+ Datasheet - Page 14

IC SENSOR TEMP SMBUS 10-UMAX

MAX6695AUB+

Manufacturer Part Number
MAX6695AUB+
Description
IC SENSOR TEMP SMBUS 10-UMAX
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6695AUB+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The MAX6696’s registers are reset to their power-on
values if RESET is driven high. When reset occurs, all
registers go to their default values, and the SMBus
address pins are sampled.
Dual Remote/Local Temperature Sensors with
SMBus Serial Interface
Table 7. Status Register 1 Bit Assignments
Table 8. Status Register 2 Bit Assignments
14
7(MSB)
7(MSB)
BIT
BIT
6
5
4
3
2
1
0
6
5
4
3
2
1
0
______________________________________________________________________________________
R1HIGH
R2HIGH
R1LOW
1OPEN
R2LOW
2OPEN
LHIGH
R1OT1
R2OT2
R1OT2
R2OT1
NAME
NAME
LLOW
BUSY
IOT1
IOT2
RFU
POR
POR
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Reset (MAX6696 Only)
A/D is busy converting when 1.
When 1, internal high-temperature ALERT has tripped, cleared by POR or by reading this status
register. If the fault condition still exists, this bit is set again after the next conversion.
When 1, internal low-temperature ALERT has tripped, cleared by POR or by reading this status
register. If the fault condition still exists, this bit is set again after the next conversion.
A 1 indicates external junction 1 high-temperature ALERT has tripped, cleared by POR or by
reading this status register. If the fault condition still exists, this bit is set again after the next
conversion.
A 1 i nd i cates exter nal j uncti on 1 l ow - tem p er atur e ALE RT has tr i p p ed , cl ear ed b y P OR or b y r ead i ng thi s
status r eg i ster . If the faul t cond i ti on sti l l exi sts, thi s b i t i s set ag ai n after the next conver si on.
A 1 indicates external diode 1 is open, cleared by POR or by reading this status register. If the
fault condition still exists, this bit is set again after the next conversion.
A 1 indicates external junction 1 temperature exceeds the OT1 threshold, cleared by reading this
register.
A 1 indicates internal junction temperature exceeds the internal OT1 threshold, cleared by
reading this register.
A 1 indicates internal junction temperature exceeds the internal OT2 threshold, cleared by
reading this register.
A 1 indicates external junction temperature 2 exceeds the external OT2 threshold, cleared by
reading this register.
A 1 indicates external junction temperature 1 exceeds the OT2 threshold, cleared by reading this
register.
A 1 indicates external junction 2 high-temperature ALERT has tripped; cleared by POR or readout
of the status register. If the fault condition still exists, this bit is set again after the next conversion.
A 1 indicates external junction 2 low-temperature ALERT has tripped; cleared by POR or readout
of the status register. If the fault condition still exists, this bit is set again after the next conversion.
A 1 indicates external diode 2 open; cleared by POR or readout of the status register. If the fault
condition still exists, this bit is set again after the next conversion.
A 1 indicates external junction 2 temperature exceeds the OT1 threshold, cleared by reading this
register.
Reserved.
The conversion-rate control register (Table 9) programs
the time interval between conversions in free-running
autonomous mode (RUN/STOP = 0). This variable rate
control can be used to reduce the supply current in
portable-equipment applications. The conversion rate
FUNCTION
FUNCTION
Conversion Rate Byte

Related parts for MAX6695AUB+