DS75LVU+ Maxim Integrated Products, DS75LVU+ Datasheet

no-image

DS75LVU+

Manufacturer Part Number
DS75LVU+
Description
IC SENSOR TEMP DIGITAL 8MSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS75LVU+

Function
Thermometer, Thermostat
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
No
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-MSOP, Micro8™, 8-uMAX, 8-uSOP,
Temperature Threshold
Programmable
Full Temp Accuracy
+/- 2 C
Digital Output - Bus Interface
2-Wire, SMBus
Digital Output - Number Of Bits
9 bit to 12 bit
Supply Voltage (max)
3.7 V
Supply Voltage (min)
1.7 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Supply Current
1000 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DESCRIPTION
This low-voltage (1.7V to 3.7V) digital thermometer
and thermostat provides 9-, 10-, 11-, or 12-bit digital
temperature readings over a -55°C to +125°C range
with ±2°C accuracy over a -25°C to +100°C range. At
power-up, the DS75LV defaults to 9-bit resolution for
software compatibility with the LM75. Communication
with the DS75LV is achieved through a simple 2-wire
serial interface. Three address pins allow up to eight
DS75LV devices to operate on the same 2-wire bus,
which greatly simplifies distributed temperature-
sensing applications.
The DS75LV thermostat has a dedicated open-drain
output (O.S.) and programmable fault tolerance,
which allows the user to define the number of
consecutive error conditions that must occur before
O.S is activated. There are two thermostatic
operating modes that control thermostat operation
based on user-defined trip-points (T
A block diagram of the DS75LV is shown in Figure 1
and detailed pin descriptions are given in Table 1.
APPLICATIONS
PIN CONFIGURATION
www.maxim-ic.com
GND
Personal Computers
Cellular Base Stations
Office Equipment
Any Thermally Sensitive System
SDA
O.S.
SCL
GND
SDA
SCL
O.S.
DS75LVS—SO (150 mils)
DS75LVU—μSOP/μMAX
1
2
3
4
1
2
3
4
6
8
7
5
8
7
6
5
V
V
A
A
A
A
A
A
DD
DD
0
0
1
2
1
2
OS
and T
HYST
).
1 of 13
Digital Thermometer and Thermostat
FEATURES
ORDERING INFORMATION
Ordering Information continued at the end of the data sheet.
DS75LVS+
DS75LVS+T&R
DS75LVU+
DS75LVU+T&R
Operating Range from 1.7V to 3.7V
Temperature Measurements Require No
External Components
Measures Temperatures from -55°C to +125°C
(-67°F to +257°F)
±2°C Accuracy Over a -25°C to +100°C Range
Thermometer Resolution is User-
Configurable from 9 (Default) to 12 Bits (0.5°C
to 0.0625°C Resolution)
9-Bit Conversion Time is 25ms (Max)
Thermostatic Settings are User-Definable
Data Read/Write Occurs Through a 2-Wire
Serial Interface (SDA and SCL Pins)
Data Lines Filtered Internally for Noise
Immunity (50ns Deglitch)
Bus Timeout Feature Prevents Lockup
Problems on 2-Wire Interface
Multidrop Capability Simplifies Distributed
Temperature-Sensing Applications
Pin/Software Compatible with the LM75
Available in 8-Pin μSOP (μMAX) and SO
Packages
PART
-55°C to +125°C
-55°C to +125°C
-55°C to +125°C
-55°C to +125°C
TEMP RANGE
DS75LV
PIN-PACKAGE
DS75LV
(150-mil) 8-SO
DS75LV
(150-mil) 8-SO,
2500 Piece
Tape-and-Reel
DS75LV
8-µSOP
(µMAX)
DS75LV
8-µSOP
(µMAX), 3000
Piece Tape-
and-Reel
112006

Related parts for DS75LVU+

DS75LVU+ Summary of contents

Page 1

... HYST Temperature-Sensing Applications Pin/Software Compatible with the LM75 Available in 8-Pin μSOP (μMAX) and SO Packages ORDERING INFORMATION DS75LVS+ DS75LVS+T&R DS75LVU+ DS75LVU+T&R Ordering Information continued at the end of the data sheet DS75LV PART TEMP RANGE -55°C to +125°C -55°C to +125°C -55°C to +125°C -55° ...

Page 2

ABSOLUTE MAXIMUM RATINGS* Voltage Relative to Ground DD Voltage on Any Other Pin, Relative to Ground Operating Temperature Range Storage Temperature Range Soldering Temperature These are stress ratings only and functional operation of the device at these ...

Page 3

Falling SCL Low Period of SCL High Period of SCL Repeated START Condition Setup Time to Rising SCL Data-Out Hold Time from Falling SCL Data-In Setup Time to Rising SCL Rise Time of SDA and SCL (Receive) Fall Time of ...

Page 4

Figure 1. DS75LV Functional Block Diagram PRECISION REFERENCE V DD SCL SDA ADDRESS AND I/O CONTROL GND Figure 2. Timing Diagram DS75LV: Digital Thermometer and Thermostat OVERSAMPLING DIGITAL MODULATOR DECIMATOR CONFIGURATION REGISTER TEMPERATURE REGISTER ...

Page 5

OPERATION⎯MEASURING TEMPERATURE The DS75LV measures temperature using a bandgap temperature sensing architecture. An on-board delta-sigma analog-to-digital converter (ADC) converts the measured temperature to a digital value that is calibrated in degrees centigrade; for Fahrenheit applications a lookup table or conversion ...

Page 6

OPERATION⎯THERMOSTAT The DS75LV thermostat has two operating modes, comparator mode and interrupt mode, which activate and deactivate the open-drain thermostat output (O.S.) based on user-programmable trip-points (T DS75LV powers up with the thermostat in comparator mode, active-low O.S. polarity, over-temperature ...

Page 7

Figure 4. O.S. OUTPUT Operation Example In this example the DS75LV is configured to have a fault tolerance of 2. Temperature O.S. Output - Comparator Mode O.S. Output - Interrupt Mode CONFIGURATION REGISTER The configuration register allows the user to ...

Page 8

Table 3. Configuration Register Bit Descriptions BIT NAME 0 Reserved R1 Conversion Resolution Bit 1 R0 Conversion Resolution Bit 0 F1 Thermostat Fault Tolerance Bit 1 F0 Thermostat Fault Tolerance Bit 0 POL Thermostat Output (O.S.) Polarity TM Thermostat Operating ...

Page 9

REGISTER POINTER The four DS75LV registers each have a unique two-bit pointer designation, which is defined in Table 6. When reading from or writing to the DS75LV, the user must “point” the DS75LV to the register that ...

Page 10

Address Byte: The control byte is transmitted by the master and consists of the 7-bit slave address plus a read/write (R/W ¯ ¯) bit (see Figure 7). If the master is going to read data from the slave device then ...

Page 11

Software POR—The soft power on reset (POR) command is 54h. The master sends a START followed by an address byte containing the DS75LV bus address. The R/W bit must The DS75LV will respond with an ACK. If ...

Page 12

Figure 9. 2-Wire Interface Timing DS75LV: Digital Thermometer and Thermostat ...

Page 13

... ORDERING INFORMATION PART TEMP RANGE DS75LVS+ -55°C to +125°C DS75LVS+T&R -55°C to +125°C DS75LVU+ -55°C to +125°C DS75LVU+T& -55°C to +125°C R DS75LVS -55°C to +125°C DS75LVS/T&R -55°C to +125°C DS75LVU -55°C to +125°C DS75LVU/T&R -55°C to +125° “+” symbol is also marked on the package near the pin 1 indicator. ...