MAX6654MEE+ Maxim Integrated Products, MAX6654MEE+ Datasheet - Page 3

IC TEMP SENSOR SMBUS 16-QSOP

MAX6654MEE+

Manufacturer Part Number
MAX6654MEE+
Description
IC TEMP SENSOR SMBUS 16-QSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6654MEE+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-55°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Full Temp Accuracy
+/- 5 C
Digital Output - Bus Interface
Serial (2-Wire, I2C)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Ic Output Type
Digital
Sensing Accuracy Range
± 5°C
Supply Current
550µA
Supply Voltage Range
3V To 5.5V
Resolution (bits)
11bit
Sensor Case Style
QSOP
No. Of Pins
16
Accuracy %
5°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ELECTRICAL CHARACTERISTICS (continued)
(V
Note 1: +25°C ≤ T
Note 2: If both the MAX6654 and the remote junction are below T
Note 3: The conversion time doubles for the extended resolution mode. This causes the average operating current to approximately
Note 4: The serial interface resets when SMBCLK is low for more than t
Note 5: Note that a transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SMBCLK’s
Logic Input Low Voltage
Logic Input High Voltage
Input Leakage Current
Output Low Sink Current
Input Capacitance
Output High Leakage Current
Serial Clock Frequency
Bus Free Time Between STOP
and START Conditions
START Condition Setup Time
Repeat START Condition Setup
Time
START Condition Hold Time
STOP Condition Setup Time
Clock Low Period
Clock High Period
Data Setup Time
Data Hold Time
Receive SCL/SDA Rise Time
Receive SCL/SDA Fall Time
SMBus Timeout
CC
= +3V to +5.5V, T
double.
falling edge.
PARAMETER
A
1°C Accurate Remote/Local Temperature
≤ +85°C.
_______________________________________________________________________________________
A
= -55°C to +125°C, unless otherwise noted. Typical values are at V
Sensor with SMBus Serial Interface
SYMBOL
t
t
t
TIMEOUT
t
t
t
SU: DAT
HD: DAT
HD:STA
SU:STO
SU:STA
I
t
t
LEAK
f
t
HIGH
LOW
V
V
I
C
SCL
BUF
OL
t
t
IH
R
F
IL
in
V
V
V
V
V
V
V
(Note 4)
90% to 90%
10% of SMBDATA to 90% of SMBCLK
90% of SMBCLK to 10% of SMBDATA662
10% to 10%
90% to 90%
90% of SMBDATA to 10% of SMBCLK
(Note 5)
SMBDATA and SMBCLK time low for reset
of serial interface
CC
CC
CC
IN
OL
OL
OH
= GND or V
= +0.4V
= +0.6V
= +3.0V to +5.5V
= +3.0V
= +5.5V
= +5.5V
CONDITIONS
CC
A
= -20°C, then V
TIMEOUT
.
CC
> 3.15V.
CC
= +3.3V and T
+250
+2.2
+2.6
+4.7
+4.7
+4.7
MIN
+50
+25
+6
+1
+4
+4
+4
0
0
TYP
+5
A
= +25°C.)
MAX
+100
+300
+0.8
+40
±2
+1
+1
UNITS
kHz
mA
ms
µA
pF
µA
µs
µs
µs
µs
µs
µs
µs
ns
µs
µs
ns
V
V
3

Related parts for MAX6654MEE+