MAX6697EP34+ Maxim Integrated Products, MAX6697EP34+ Datasheet - Page 9

IC TEMP MON 7CH PREC 20-QSOP

MAX6697EP34+

Manufacturer Part Number
MAX6697EP34+
Description
IC TEMP MON 7CH PREC 20-QSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6697EP34+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Buffer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
20-QSOP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 3. SMBus Write Timing Diagram
Figure 4. SMBus Read Timing Diagram
the conversion sequence. Depending on operating
conditions, a shorted diode may or may not cause
ALERT or OVERT to assert, so if a channel will not be
used, disconnect its DXP and DXN inputs.
There are 11 alarm threshold registers that store over-
temperature ALERT and OVERT threshold values.
Seven of these registers are dedicated to store one
local alert temperature threshold limit and six remote
alert temperature threshold limits (see the ALERT
Interrupt Mode section). The remaining four registers
are dedicated to remote channels 1, 4, 5, and 6 to store
overtemperature threshold limits (see the OVERT
SMBCLK
SMBDATA
SMBCLK
SMBDATA
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
t
t
SU:STA
SU:STA
A
A
t
HD:STA
7-Channel Precision Temperature Monitor
t
HD:STA
_______________________________________________________________________________________
t
LOW
Alarm Threshold Registers
t
LOW
B
t
B
HIGH
t
HIGH
t
SU:DAT
t
SU:DAT
C
C
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
D
D
E
F
E
F
Overtemperature Alarm section). Access to these regis-
ters is provided through the SMBus interface.
An ALERT interrupt occurs when the internal or external
temperature reading exceeds a high-temperature limit
(user programmable).The ALERT interrupt output signal
can be cleared by reading the status register(s) associ-
ated with the fault(s) or by successfully responding to
an alert response address transmission by the master.
In both cases, the alert is cleared but is reasserted at
the end of the next conversion if the fault condition still
exists. The interrupt does not halt automatic conversions.
The ALERT output is open drain so that multiple devices
t
HD:DAT
G
G
I = MASTER PULLS DATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
H
H
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION
I
ALERT Interrupt Mode
I
J
J K
K
t
SU:STO
t
SU:STO
L
L
t
BUF
t
BUF
M
M
9

Related parts for MAX6697EP34+