W83792AG Nuvoton Technology Corporation of America, W83792AG Datasheet - Page 58

no-image

W83792AG

Manufacturer Part Number
W83792AG
Description
IC MONITOR H/W 48-LQFP
Manufacturer
Nuvoton Technology Corporation of America
Datasheet

Specifications of W83792AG

Output Type
I²C™
Function
Hardware Monitor
Topology
ADC, Fan Control, Register Bank
Sensor Type
External
Sensing Temperature
External Sensor
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Temperature Sensor Function
Temp Sensor
Resolution
10b
Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.5V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W83792AG
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
Company:
Part Number:
W83792AG
Quantity:
97
8.26 Fan Step Down/Up Time Register -- Index 8Eh 8Fh(Bank 0)
Reset Condition: Resume Reset, INIT, 5VDD posedge.
FAN Step Up Time
FAN Step Down Time
8.27 Fan 1/2/3 Smart Fan II Temperature/ Duty Cycle setups -- Index E0h~EBh
FAN 1 Temperature Point 2
FAN 1 Temperature Point 3
FAN 1 Temperature Point 4
FAN 2 Temperature Point 2
FAN 2 Temperature Point 3
FAN 2 Temperature Point 4
BIT
7-0
BIT
7-0
FAN 1 Duty Cycle Level
FAN 2 Duty Cycle Level
FAN 3 Duty Cycle Level
FAN Step Down Time
FAN Step Up Time
5Fh(Bank 0)
MNEMONIC
STEP_UP_T
Mnemonic
STEP_DOWN_T
NAME
NAME
Bank
ATTRIBUTE
BANK INDEX ATTR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
0
0
0
0
0
0
0
0
0
ATTRIBUTE
0
0
R/W
R/W
Index
E0
E1
E2
E3
E4
E5
E6
E7
E8
8E
8F
The time interval, which is 0.1 second unit, to increase PWM
Attr
duty in Thermal Cruise mode.
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
The time interval, which is 0.1 second unit, to decrease
PWM duty in Thermal Cruise mode.
reserve
reserve
reserve
reserve
reserve
reserve
BIT 7
0
0
0
0
0
0
- 52 -
Fan Duty Cycle Level 2
Fan Duty Cycle Level 2
Fan Duty Cycle Level 2
BIT 6
8h
8h
8h
BIT 5
DESCRIPTION
DESCRIPTION
W83792AD/AG/D/G
BIT 4
Temperature Point 2
Temperature Point 3
Temperature Point 4
Temperature Point 2
Temperature Point 3
Temperature Point 4
DOWNTIME
0Ah (1 sec)
0Ah (1 sec)
UPTIME
BIT 3
3Ch
3Ch
28h
50h
28h
50h
Fan Duty Cycle Level 3
Fan Duty Cycle Level 3
Fan Duty Cycle Level 3
BIT 2
Bh
Bh
Bh
BIT 1
BIT 0

Related parts for W83792AG