MAX6518UKP055+T Maxim Integrated Products, MAX6518UKP055+T Datasheet - Page 4

IC TEMP SENSOR SW SOT23-5

MAX6518UKP055+T

Manufacturer Part Number
MAX6518UKP055+T
Description
IC TEMP SENSOR SW SOT23-5
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6518UKP055+T

Function
Temp Switch
Topology
Comparator, Voltage Reference
Sensor Type
Internal
Sensing Temperature
55°C Trip Point
Output Type
Active High/Push-Pull
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
SOT-23-5, SC-74A, SOT-25
Temperature Threshold
+ 55 C
Full Temp Accuracy
+/- 3 C
Gain
- 10.62 mV / C
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Low-Cost, 2.7V to 5.5V, Analog Temperature
Sensor Switches in a SOT23
4
(V
MAX6516 MAX6517
CC
_______________________________________________________________________________________
1
2
3
4
5
5
= 5V, T
A
STARTUP AND POWER-DOWN
= +25°C, unless otherwise noted.)
1
2
3
4
5
5
(TEMP < T
200μs/div
PIN
MAX6518 MAX6519
TH
3
2
1
4
5
5
)
MAX6516 toc10
3
2
1
4
5
5
V
TOVER (5V/div)
V
CC
OUT
(5V/div)
(5V/div)
Typical Operating Characteristics (continued)
TUNDER
TUNDER
TOVER
TOVER
NAME
HYST
GND
OUT
V
CC
Analog Output. Voltage represents the die’s temperature.
Ground
Hysteresis Input. Connect to V
10°C hysteresis.
Input Supply. Bypass to ground with a 0.1µF capacitor.
Push-Pull Active-High Output (Hot Threshold). TOVER goes high when
the die temperature exceeds the factory-programmed hot temperature
threshold.
Open-Drain, Active-Low Output (Hot Threshold). TOVER goes low
when the die temperature exceeds the factory-programmed hot
temperature threshold. Connect to a 100kΩ pullup resistor. May be
pulled up to a voltage higher than V
Push-Pull Active-High Output (Cold Threshold). TUNDER goes high
when the die temperature falls below the factory-programmed cold
temperature threshold.
Open-Drain, Active-Low Output (Cold Threshold). TUNDER goes low
when the die temperature goes below the factory-programmed cold
temperature threshold. Connect to a 100kΩ pullup resistor. May be
pulled up to a voltage higher than V
STARTUP DELAY
(TEMP > T
FUNCTION
200μs/div
CC
for 2°C of hysteresis or to GND for
CC
CC
TH
.
.
)
MAX6516 toc11
Pin Description
V
TOVER (5V/div)
V
CC
OUT
(5V/div)
(5V/div)