MAX6602UE9A+T Maxim Integrated Products, MAX6602UE9A+T Datasheet - Page 8

IC TEMP MONITOR 5CH 16-TSSOP

MAX6602UE9A+T

Manufacturer Part Number
MAX6602UE9A+T
Description
IC TEMP MONITOR 5CH 16-TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6602UE9A+T

Function
Temp Monitoring System (Sensor)
Topology
ADC, Buffer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP
Full Temp Accuracy
+/- 1 C, +/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
conversion results until they have been read. If the
most significant bits have not been read within an
SMBus timeout period (nominally 37ms), normal updat-
ing continues. Table 1 shows the main temperature
register (high byte) data format, and Table 2 shows the
extended resolution register (low byte) data format.
If a channel’s input DXP_ and DXN_ are left open, the
MAX6602 detects a diode fault. An open diode fault
Five-Channel Precision Temperature Monitor
Figure 2. SMBus Protocols
8
Table 1. Main Temperature Register
(High Byte) Data Format
Write Byte Format
Read Byte Format
Send Byte Format
S = Start condition
P = Stop condition
Diode fault (short or open)
S
S
_______________________________________________________________________________________
S
ADDRESS
Slave Address: equiva-
lent to chip-select line
ADDRESS
TEMP (°C)
7 bits
Slave Address: equiva-
lent to chip-select line of
a 3-wire interface
7 bits
> +127
+127
+126
+25
< 0
ADDRESS
0
7 bits
WR
WR
Shaded = Slave transmission
/// = Not acknowledged
ACK
Diode Fault Detection
ACK
WR
Command Byte: sends com-
mand with no data, usually
used for one-shot command
COMMAND
DIGITAL OUTPUT
Command Byte: selects
from which register you
are reading
8 bits
COMMAND
0111 1111
0111 1111
0111 1110
0001 1001
0000 0000
0000 0000
1111 1111
ACK
8 bits
ACK
Command Byte: selects to
which register you are writing
ACK
COMMAND
P
8 bits
S
Receive Byte Format
does not cause either ALERT or OVERT to assert. A bit
in the status register for the corresponding channel is
set to 1 and the temperature data for the channel is
stored as all 1s (FFh). It takes approximately 4ms for
the MAX6602 to detect a diode fault. Once a diode fault
is detected, the MAX6602 goes to the next channel in
the conversion sequence. Depending on operating
conditions, a shorted diode may or may not cause
ALERT or OVERT to assert, so if a channel will not be
used, disconnect its DXP and DXN inputs.
Table 2. Extended Resolution Temperature
Register (Low Byte) Data Format
S
Slave Address: repeated
due to change in data-
flow direction
ADDRESS
7 bits
ADDRESS
ACK
TEMP (°C)
7 bits
+0.125
+0.250
+0.375
+0.500
+0.625
+0.725
+0.875
0
Data Byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)
RD
DATA
RD
8 bits
ACK
ACK
Data Byte: reads data from
the register commanded
by the last read byte or
write byte transmission;
also used for SMBus alert
response return address
Data Byte: reads from
the register set by the
command byte
DATA
8 bits
DATA
8 bits
DIGITAL OUTPUT
ACK
000X XXXX
001X XXXX
010X XXXX
011X XXXX
100X XXXX
101X XXXX
110X XXXX
111X XXXX
///
///
P
1
P
P