AD597AH Analog Devices Inc, AD597AH Datasheet

IC THERMOCOUPLE COND TO-100-10

AD597AH

Manufacturer Part Number
AD597AH
Description
IC THERMOCOUPLE COND TO-100-10
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD597AH

Rohs Status
RoHS non-compliant
Function
Thermocouple Conditioner
Topology
Ice Point Compensation
Sensor Type
External
Sensing Temperature
-200°C ~ 1250°C
Output Type
Voltage
Output Alarm
Yes
Output Fan
No
Voltage - Supply
5 V ~ 30 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Through Hole
Package / Case
TO-100, Metal Can (10 Leads)
Ic Output Type
Voltage
Sensing Accuracy Range
± 4°C
Supply Current
160µA
Supply Voltage Range
5V To 30V
Sensor Case Style
TO-100
No. Of Pins
10
Termination Type
Through Hole
Filter Terminals
Through Hole
Rohs Compliant
No
Accuracy
± 4
Accuracy %
4°C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD597AH
Manufacturer:
AD
Quantity:
5 510
Part Number:
AD597AH
Manufacturer:
ADI
Quantity:
485

Related parts for AD597AH

AD597AH Summary of contents

Page 1

...

Page 2

... Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All min and max specifications are guaranteed, although only those shown in boldface Model AD596AH AD597AH AD597AR* *Consult factory for availability. (@ +60 C and V unless otherwise noted) AD596AH AD597AH Typ Max Min Typ 36 – 0.15) +V (–V – 0.15) ...

Page 3

Table I. Output Voltage vs. Thermocouple Temperature (Ambient + Thermocouple Type J AD596 Temperature Voltage Output –200 –7.890 –1370 –180 –7.402 –1282 –160 –6.821 –1177 –140 –6.159 –1058 –120 –5.426 –925 –100 –4.632 –782 –80 ...

Page 4

AD596/AD597 TEMPERATURE PROPORTIONAL OUTPUT MODE The AD596/AD597 can be used to generate a temperature proportional output of 10 mV/ C when operated with J and K type thermocouples as shown in Figure 1. Thermocouples pro- duce low level output voltages ...

Page 5

SETPOINT CONTROL MODE The AD596/AD597 can be connected as a setpoint controller as shown in Figure 2. The thermocouple voltage is cold junction compensated, amplified, and compared to an external setpoint voltage. The relationship between setpoint voltage and tempera- ture ...

Page 6

AD596/AD597 SINGLE AND DUAL SUPPLY CONNECTIONS In the single supply configuration as used in the setpoint con- troller of Figure 2, any convenient voltage from + +36 V may be used, with self-heating errors being minimized at lower ...

Page 7

TEMPERATURE CONSTANTAN (ALUMEL) IRON (CHROMEL) HEATER REV 470 – AD596/ 45.2k AD597* 10k 1.27M +V 5V 40.2k AD584 10k – 1k SET-POINT ADJUST 10k OP07 5k + 10M Figure 6. Temperature Measurement and Control –7– AD596/AD597 ...

Page 8

AD596/AD597 0.040 (1.02) MAX OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 10-Pin Metal Can (TO-100) REFERENCE PLANE 0.750 (19.05) 0.500 (12.70) 0.185 (4.70) 0.160 (4.06) 0.165 (4.19) 0.250 (6.35) MIN 0.110 (2.79) 0.050 (1.27) MAX 6 5 0.115 4 ...