LT1576IS8-5#TRPBF Linear Technology, LT1576IS8-5#TRPBF Datasheet - Page 11

IC REG SW 5V 1.5A STEPDOWN 8SOIC

LT1576IS8-5#TRPBF

Manufacturer Part Number
LT1576IS8-5#TRPBF
Description
IC REG SW 5V 1.5A STEPDOWN 8SOIC
Manufacturer
Linear Technology
Type
Step-Down (Buck)r
Datasheet

Specifications of LT1576IS8-5#TRPBF

Internal Switch(s)
Yes
Synchronous Rectifier
No
Number Of Outputs
1
Voltage - Output
5V
Current - Output
1.5A
Frequency - Switching
200kHz
Voltage - Input
5 ~ 25 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power - Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LT1576IS8-5#TRPBFLT1576IS8-5
Manufacturer:
LT
Quantity:
10 000
Company:
Part Number:
LT1576IS8-5#TRPBF
Manufacturer:
LINEAR
Quantity:
8 456
Company:
Part Number:
LT1576IS8-5#TRPBFLT1576IS8-5SYNC
Manufacturer:
LT
Quantity:
10 000
Company:
Part Number:
LT1576IS8-5#TRPBFLT1576IS8-5SYNC#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LT1576IS8-5#TRPBFLT1576IS8-5SYNC#TRPBF
Manufacturer:
LINEAR
Quantity:
7 233
APPLICATIONS
Example: with L = 5 H, V
The main reason for using such a tiny inductor is that it is
physically very small, but keep in mind that peak-to-peak
inductor current will be very high. This will increase output
ripple voltage. If the output capacitor has to be made larger
to reduce ripple voltage, the overall circuit could actually
wind up larger.
CHOOSING THE INDUCTOR AND OUTPUT CAPACITOR
For most applications the output inductor will fall in the
range of 15 H to 60 H. Lower values are chosen to reduce
physical size of the inductor. Higher values allow more
output current because they reduce peak current seen by
the LT1576 switch, which has a 1.5A limit. Higher values
also reduce output ripple voltage, and reduce core loss.
Graphs in the Typical Performance Characteristics section
show maximum output load current versus inductor size
and input voltage. A second graph shows core loss versus
inductor size for various core materials.
When choosing an inductor you might have to consider
maximum load current, core and copper losses, allowable
component height, output voltage ripple, EMI, fault cur-
rent in the inductor, saturation, and of course, cost. The
following procedure is suggested as a way of handling
these somewhat complicated and conflicting requirements.
1. Choose a value in microhenries from the graphs of
I
Discontinuous mode
I
OUT MAX
OUT(MAX)
maximum load current and core loss. Choosing a small
inductor may result in discontinuous mode operation
at lighter loads, but the LT1576 is designed to work
well in either mode. Keep in mind that lower core loss
means higher cost, at least for closed core geometries
like toroids. The core loss graphs show both absolute
loss and percent loss for a 5W output, so actual percent
losses must be calculated for each situation.
=
1 5
U
2
200 10
INFORMATION
OUT
2 5 15 5
U
2
V
= 5V, and V
OUT
I
3
P
2
5 10
W
f L V
V
IN
6
IN(MAX
V
IN
OUT
15
U
) = 15V,
0 34
A
2. Calculate peak inductor current at full load current to
3. Decide if the design can tolerate an “open” core geom-
4. Start shopping for an inductor (see representative
Assume that the average inductor current is equal to
load current and decide whether or not the inductor
must withstand continuous fault conditions. If maxi-
mum load current is 0.5A, for instance, a 0.5A inductor
may not survive a continuous 1.5A overload condition.
Dead shorts will actually be more gentle on the induc-
tor because the LT1576 has foldback current limiting.
ensure that the inductor will not saturate. Peak current
can be significantly higher than output current, espe-
cially with smaller inductors and lighter loads, so don’t
omit this step. Powdered iron cores are forgiving
because they saturate softly, whereas ferrite cores
saturate abruptly. Other core materials fall somewhere
in between. The following formula assumes continu-
ous mode of operation, but it errs only slightly on the
high side for discontinuous mode, so it can be used for
all conditions.
V
f = Switching frequency, 200kHz
etry like a rod or barrel, with high magnetic field
radiation, or whether it needs a closed core like a toroid
to prevent EMI problems. One would not want an open
core next to a magnetic storage media, for instance!
This is a tough decision because the rods or barrels are
temptingly cheap and small and there are no helpful
guidelines to calculate when the magnetic field radia-
tion will be a problem.
surface mount units in Table 2) which meets the require-
ments of core shape, peak current (to avoid saturation),
average current (to limit heating), and fault current (if
the inductor gets too hot, wire insulation will melt and
cause turn-to-turn shorts). Keep in mind that all good
things like high efficiency, low profile, and high tempera-
ture operation will increase cost, sometimes dramati-
cally. Get a quote on the cheapest unit first to calibrate
yourself on price, then ask for what you really want.
IN
I
PEAK
= Maximum input voltage
I
OUT
V
OUT
2
f L V
V
LT1576/LT1576-5
IN
V
IN
OUT
11

Related parts for LT1576IS8-5#TRPBF