ADUM1201CRZ-RL7 Analog Devices Inc, ADUM1201CRZ-RL7 Datasheet - Page 21

IC ISOLATOR DIGITAL DUAL 8SOIC

ADUM1201CRZ-RL7

Manufacturer Part Number
ADUM1201CRZ-RL7
Description
IC ISOLATOR DIGITAL DUAL 8SOIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM1201CRZ-RL7

Propagation Delay
45ns
Inputs - Side 1/side 2
1/1
Number Of Channels
2
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
50Mbps
Output Type
Logic
Package / Case
8-SOIC (3.9mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
2
Supply Current
6.3mA
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
8
Operating Temperature Range
-40°C To +105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ADUM1201CRZ-RL7
ADUM1201CRZ-RL7TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM1201CRZ-RL7
Manufacturer:
AD
Quantity:
3 500
Part Number:
ADUM1201CRZ-RL7
Manufacturer:
SONY
Quantity:
6 221
Part Number:
ADUM1201CRZ-RL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 13.
Parameter
Storage Temperature (T
Ambient Operating Temperature (T
Ambient Operating Temperature (T
Supply Voltages (V
Input Voltages (V
Output Voltages (V
Average Output Current per Pin (I
Common-Mode Transients (CM
1
2
3
4
5
6
Does not apply to ADuM1200W and ADuM1200W automotive grade
products.
Applies to ADuM1200W and ADuM1201W automotive grade products.
All voltages are relative to their respective ground.
V
given channel, respectively.
See
Refers to common-mode transients across the insulation barrier.
Common-mode transients exceeding the absolute maximum ratings
can cause latch-up or permanent damage.
DDI
and V
Figure 3
DDO
for maximum rated current values for various temperatures.
refer to the supply voltages on the input and output sides of a
IA
DD1
OA
, V
, V
, V
IB
)
OB
DD2
3, 4
ST
)
3, 4
)
)
3
L
, CM
O
A
A
)
)
)
H
1
2
5
)
6
Rating
−55°C to +150°C
−40°C to +105°C
−40°C to +125°C
−0.5 V to +7.0 V
−0.5 V to V
−0.5 V to V
−11 mA to +11 mA
−100 kV/μs to +100 kV/μs
DDI
DDO
+ 0.5 V
+ 0.5 V
Rev. H | Page 21 of 28
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 14. Maximum Continuous Working Voltage
Parameter
AC Voltage,
Bipolar
Waveform
AC Voltage,
Unipolar
Waveform
Functional
Insulation
Basic
Insulation
DC Voltage
Functional
Insulation
Basic
Insulation
1
See the Insulation Lifetime section for more details.
ESD CAUTION
Refers to continuous voltage magnitude imposed across the isolation barrier.
Max
565
1131
560
1131
560
Unit
V peak
V peak
V peak
V peak
V peak
ADuM1200/ADuM1201
Constraint
50-year minimum lifetime
Maximum approved
working voltage per IEC
60950-1
Maximum approved
working voltage per IEC
60950-1 and VDE V 0884-
10
Maximum approved
working voltage per IEC
60950-1
Maximum approved
working voltage per IEC
60950-1 and VDE V 0884-
10
1

Related parts for ADUM1201CRZ-RL7