HCPL-3760-000E Avago Technologies US Inc., HCPL-3760-000E Datasheet - Page 6

OPTOCOUPLER AC/DC LOGIC 8-DIP

HCPL-3760-000E

Manufacturer Part Number
HCPL-3760-000E
Description
OPTOCOUPLER AC/DC LOGIC 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-3760-000E

Output Type
Open Collector
Package / Case
8-DIP (0.300", 7.62mm)
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
30mA
Propagation Delay High - Low @ If
4.5µs
Current - Dc Forward (if)
50mA
Input Type
Logic
Mounting Type
Through Hole
Logic Gate Type
AC / DC to Logic Interface Optocouplers
Configuration
1 Channel
Isolation Voltage
3750 Vrms
Maximum Propagation Delay Time
40000 ns
Maximum Forward Diode Voltage
50 mA
Maximum Forward Diode Current
2.2 mA
Maximum Continuous Output Current
30 mA
Maximum Power Dissipation
305 mW
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
No. Of Channels
1
Optocoupler Output Type
Photodarlington
Input Current
1.8mA
Output Voltage
20V
Opto Case Style
DIP
No. Of Pins
8
Common Mode Ratio
4000
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-1677-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-3760-000E
Manufacturer:
AVAGO
Quantity:
5 000
Part Number:
HCPL-3760-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Insulation and Safety Related Specifications
6
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the
2. Safety-limiting parameters are dependent on case temperature. The Input Current, I
Parameter
Min.. External Air Gap
(External Clearance)
Min.. External Tracking
Path (External Creepage)
Min.. Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative
Tracking Index)
Isolation Group
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
V
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a
V
Partial Discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Insulation Resistance at T
IORM
IORM
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
Case Temperature
Input Current [2]
Output Power [2]
application.
at a rate of 1.2 mA/°C and 1.53 mA/°C for HCPL-0370 and HCPL-3700/3760 respectively; the Output Power, P
free-air case temperature at a rate of 4.8 mW/°C and 4 mW/°C for HCPL-0370 and HCPL-3700/3760 respectively.
x 1.875 = V
x 1.6 = V
PR
, Type and sample test, tm = 10 sec,
PR
, 100% Production Test with tm = 1 sec
S
, V
IO
Symbol
CTI
L(IO1)
L(IO2)
= 500 V
8-Pin DIP
(300 mil)
Value
0.08
200
7.1
7.4
Value
SO-8
0.08
200
4.9
4.8
IIIa
[1]
(with option 060)
Units
mm
mm
mm
V
Symbol
V
V
V
V
T
I
P
R
S,INPUT
S
IORM
PR
PR
IOTM
S,OUTPUT
S
Conditions
Measured from input terminals to output
terminals, hortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
Through insulation distance, conductor to
conductor, usually the direct distance between
the photoemitter and photodetector inside the
optocoupler cavity
DIN IEC 112/VDE 0303 PART 1
Material Group (DIN VDE 0110, 1/89, Table 1)
S,INPUT
, derates linearly above 25°C free-air case temperature
HCPL-0370
55/85/21
1063
6000
567
907
150
150
600
109
I-IV
I-IV
I-III
2
S,OUTPUT
HCPL-3700/3760 Units
55/85/21
, derates linearly above 25°C
1181
1008
6000
630
175
230
600
109
I-IV
I-IV
I-III
2
V peak
V peak
V peak
V peak
°C
mA
mW
W

Related parts for HCPL-3760-000E