HCPL-7560-500 Avago Technologies US Inc., HCPL-7560-500 Datasheet - Page 5

no-image

HCPL-7560-500

Manufacturer Part Number
HCPL-7560-500
Description
OPTOCOUPLER MODULE 8-SMD
Manufacturer
Avago Technologies US Inc.
Type
Sigma-Delta Modulatorr
Datasheet

Specifications of HCPL-7560-500

Voltage - Isolation
3750Vrms
Input Type
DC
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SMD Gull Wing
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-7560-500
Manufacturer:
AVAGO
Quantity:
40 000
Part Number:
HCPL-7560-500E
Manufacturer:
AVAGO
Quantity:
40 000
Regulatory Information
The HCPL-7560 has been approved by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
UL
Approval under UL 1577, component recognition program up to V
CSA
Approval under CSA Component Acceptance Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/
3. Refer to the following figure for dependence of P
5
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
V
Partial discharge < 5 pC
Input to Output Test Voltage, Method a
V
Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage t
Safety-limiting values - maximum values allowed in the event of a failure,
also see Figure 13.
Insulation Resistance at T
IORM
IORM
application. Surface Mount Classifications is Class A in accordance with CECC00802.
EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
for rated mains voltage
for rated mains voltage
for rated mains voltage
Case Temperature
Input Current
Output Power
x 1.875=V
x 1.5=V
PR
, Type and Sample Test, t
PR
[3]
[3]
, 100% Production Test with t
ini
S
, V
= 10 sec)
300 Vrms
450 Vrms
600 Vrms
IO
= 500 V
[2]
[2]
m
S
=60 sec,
and I
[1]
S
on ambient temperature.
m
=1 sec,
ISO
= 3750 V
Symbol
V
V
V
V
T
I
P
R
RMS
S, INPUT
S
S, OUTPUT
S
IORM
PR
PR
IOTM
. File E55361.
HCPL-7560
I - IV
I - III
I - II
40/85/21
2
891
1670
1336
6000
175
400
600
>10
9
Unit
V
V
V
V
°C
mA
mW
W
peak
peak
peak
peak

Related parts for HCPL-7560-500