8028300000 Weidmuller, 8028300000 Datasheet - Page 79

no-image

8028300000

Manufacturer Part Number
8028300000
Description
OPTOCOUPLER DKO TS35 24VDC 3KHZ
Manufacturer
Weidmuller
Datasheets

Specifications of 8028300000

Number Of Channels
1
Input Type
DC
Voltage - Output
5V
Current - Output / Channel
20mA
Output Type
Transistor
Mounting Type
DIN Rail
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Dc Forward (if)
-
Voltage - Isolation
-
Vce Saturation (max)
-
Current Transfer Ratio (max)
-
Current Transfer Ratio (min)
-
Other names
DKO 35 24VDC 3KHZ
Continuous
current
136
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Output supply voltage
Voltage drop at max. load current
Output current
Derating curve
a = rowed on mounting rail without clearances
b = rowed with clearances ≥ 20 mm
Pulse duration, limiting overload current (not periodic)
Sperrstrom (Ruhestrom), max. at U = 48 V
Switch-on time (cyclic operation)
Switch-off time (cyclic operation)
Max. switching frequency DC voltage
Max. switching frequency AC voltage
Switching ratio
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Opto-coupler
Test voltage (corresponds 100% module test)
Module is immune to interference
Insulation voltage
Input – output/mounting rail
Storage temperature
Ambient temperature
–, rowed on mounting rail without clearances
–, rowed with clearances ≥ 20 mm
Rated data
Insulation coordination to EN 50 178
Opto-coupler on locking socket profile RS 40
Opto-couplers
for signal input
Ambient temperature
1
2
5 V–
0.045 W
5…48 V–
< 0.9 V
20 mA
0.2 A/10 ms
0.16 mA
≤ 12 µs
≤ 15 µs
3 kHz
1 : 2
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4
severity 4
4 kV~
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
RS 40
) Not TTL-compatible
) Conditionally level-compatible
2
)
eff
1 min.
1
)
12 V0 ± 10 %
0.25 W
0.32 VA
5…48 V–
< 1.6 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 6 ms
≤ 13 ms
20 Hz
< 10 Hz
10 Hz 1 : 2
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)
20 or 100
24 V– ± 10 %
0.51 W
5…48 V–
< 0.9 V
20 mA
0.2 A/10 ms
0.16 mA
≤ 30 µs
≤ 60 µs
3 kHz
1 : 2
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)
24 V0 ± 10 %
0.34 W
0.5 VA
5…48 V–
< 1.6 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 2 ms
≤ 15 ms
20 Hz
10 Hz 1 : 1
300 V
6 kV
III
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)
48 V0 ± 10 %
0.55 W
0.65 VA
5…48 V–
< 1.6 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 5 ms
≤ 20 ms
< 20 Hz
< 10 Hz
10 Hz 1 : 1
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)
20 or
100
115 V0, +5%-15% 230 V~, +5%-15%
0.33 W
0.65 VA
5…48 V–
< 1.5 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 10 ms
≤ 23 ms
10 Hz
10 Hz 1 : 1
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
4 kV~
–40 °C…+70 °C
–25 °C…+40 °C
–25 °C…+45 °C
eff
1 min.
1
)
0.52 VA
5…48 V–
< 1.5 V
100 mA
0.8 A/10 ms
0.16 mA
≤ 6 ms
≤ 18 ms
10 Hz 1 : 1
300 V
6 kV
IV
2
≥ 5.5 mm
according to
DIN VDE 0884
according to
DIN VDE 0884
non-destructive
test 1 kV
severity 4
1
)

Related parts for 8028300000