Specifications of SMART1050SLT

Power - Rated
1.05kVA / 650W
Ac Outlets
8 (UPS)
Features
DB9 and USB Cable
Backup Time - Max Load
7 minutes
Media Lines Protected
1 - RJ11 Line
Voltage - Output Per Connector
120V
Voltage - Input
120V / 15A
Cord Length
6' (1.83m)
Ac Input Connector
NEMA 5-15P
Connector - Ac Output
NEMA 5-15R
Size
13.25" L x 6.75" W x 10.25" H (336.6mm x 171.5mm x 260.4mm)
Weight
36 lbs (16.3kg)
Ac Output Connector
NEMA 5-15R
Brand/series
SmartPro®
Capacity
1050 VA
Color
Black
Communication
DB9, RJ45, USB
Current, Rating
9.2 A (Max.)
Dimensions
26.04cmH×17.15cmW×33.7cmD
Frequency, Output
60 Hz
Input Type
NEMA 5-15P
Length, Cord
6 ft.
Mounting Type
Rack/Tower
Operation
Line-Interactive
Output Type
(8) NEMA 5-15R
Power, Rating
650 W
Standards
cUL, UL Listed
Temperature, Operating
0 to +40 °C
Time, Backup
7 min.
Voltage Regulation
120 V (Sine Wave Output) within ± 5% @ Battery Mode
Voltage, Battery
36 VDC
Voltage, Input
120 V
Voltage, Nominal
100, 110, 120 or 127 VAC (Nom.)
Voltage, Output
127 VAC
Voltage, Supply
650/1050 W/VA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
UPS Input cord length (m)
Recommended Electrical
Service
BATTERY
Full load runtime
(minutes)
Half load runtime
(minutes)
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
LEDS ALARMS & SWITCHES
LED Indicators
Site wiring fault indication
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
UPS AC suppression
response time
UPS Dataline suppression
EMI / RFI AC noise
suppression
PHYSICAL
Installation form factors
supported with included
accessories
Primary form factor
1.8
15A 120V
7 min. (650w)
19 min. (325w)
24
Less than 6 hours from 10% to 90%
RBC24-SLT
Battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 95 to 145
(120v), 87 to 133 (110v), 83 to 121 (100v)
Voltage reduction of 12% applies when input is 127 to 145 (120v), 116 to 133 (110v), 111 to 121 (100v)
Voltage boost of 14% applies when input is 95 to 108 (120v), 87 to 99 (110v), 83 to 90 (100v)
9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter
for load and battery charge level
Rear panel site wiring fault LED
Audible alarm indicates power failure and overload conditions
Power-fail alarm can be silenced using alarm-cancel switch
2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches
support nominal voltage selection
690
Instantaneous
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
Yes
Tower
Tower

Related parts for SMART1050SLT