OMNISMART1400 Tripp Lite, OMNISMART1400 Datasheet - Page 3

UPS 1400VA 940W 6OUT W/SOFTWARE

OMNISMART1400

Manufacturer Part Number
OMNISMART1400
Description
UPS 1400VA 940W 6OUT W/SOFTWARE
Manufacturer
Tripp Lite
Series
OmniSmart™r
Type
UPSr
Datasheet

Specifications of OMNISMART1400

Rohs Status
Not applicable
Power - Rated
1.4kVA / 940W
Ac Outlets
6 (UPS)
Backup Time - Max Load
8 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 15A
Cord Length
6' (1.83m)
Ac Input Connector
NEMA 5-15P
Connector - Ac Output
NEMA 5-15R
Size
9.00" L x 7.50" W x 12.75" H (228.6mm x 190.5mm x 323.9mm)
Weight
37 lbs (16.8kg)
Ac Output Connector
NEMA 5-15R
Power Rating
1400 VA
Output Voltage Rating
120 V
Number Of Outlets
6
Interface Port
USB
Runtime (full Load)
8 min
Runtime (half Load)
24 min
Topology
Line Interactive
Tower / Rackmount
Tower
Features
-
Media Lines Protected
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
OMNISMART1400PNP
TL171
UPS input connection type
UPS Input cord length (ft.)
UPS Input cord length (m)
Recommended Electrical
Service
Input cord length (ft.)
Input cord length (m)
BATTERY
Full load runtime (minutes)
Half load runtime
(minutes)
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
UPS AC suppression
response time
EMI / RFI AC noise
suppression
AC suppression joule
rating
AC suppression response
time
PHYSICAL
5-15P
6
1.8
15A 120V
6
1.8
8 min. (940w)
24 min. (470w)
36
Less than 8 hours from 10% to 90%
RBC53
Battery access door
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
Input voltages between 128 and 147 are reduced by 12%
Input voltages between 93 and 107 are boosted by 14%
Input voltages between 75 and 92 are boosted by 30%
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation
480
Instantaneous
Yes
480
Instantaneous