SMART5000TEL3U Tripp Lite, SMART5000TEL3U Datasheet - Page 3

UPS 5KVA 3750W 5OUT W/SOFTWARE

SMART5000TEL3U

Manufacturer Part Number
SMART5000TEL3U
Description
UPS 5KVA 3750W 5OUT W/SOFTWARE
Manufacturer
Tripp Lite
Series
Smart Pro®r
Type
Power Supply Regulatorr
Datasheet

Specifications of SMART5000TEL3U

Rohs Status
Not applicable
Power - Rated
5kVA / 3750W
Ac Outlets
5 (UPS)
Features
DB9 and USB Communications, Rack Mount
Backup Time - Max Load
10 minutes
Voltage - Output Per Connector
208V (1 NEMA L6-30R, 2 NEMA L6-20R and 2 NEMA 5-15R)
Voltage - Input
208V / 30A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA L6-30P
Connector - Ac Output
1 NEMA L6-30R, 2 NEMA L6-20R and 2 NEMA 5-15R
Size
25.00" L x 17.50" W x 5.25" H (635.0mm x 444.5mm x 133.4mm)
Weight
143 lbs (64.9kg)
Ac Output Connector
1 NEMA L6-30R, 2 NEMA L6-20R and 2 NEMA 5-15R
Media Lines Protected
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
UPS input connection
type
UPS Input cord length
(ft.)
UPS Input cord length
(m)
Recommended
Electrical Service
BATTERY
Full load runtime
(minutes)
Half load runtime
(minutes)
DC system voltage
(VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
UPS AC suppression
response time
EMI / RFI AC noise
suppression
PHYSICAL
Installation form factors
supported with included
accessories
L6-30P
10
3
30A 208V
8.5 min. (3750w)
20 min. (1875w)
48
Less than 4 hours from 10% to 90%
RBC94-3U
Front panel battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260
Input voltages between 228V and 260V are reduced by 12%
Input voltages between 167V and 194V are boosted by 12%
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation
1020
Instantaneous
Yes
4 post 19 inch rackmount (mounting rail kit included)
(quantity 3)

Related parts for SMART5000TEL3U