NHD-0216K1Z-FS(RGB)-FBW Newhaven Display, NHD-0216K1Z-FS(RGB)-FBW Datasheet

LCD MOD CHAR 2X16 RGB TRANSFL

NHD-0216K1Z-FS(RGB)-FBW

Manufacturer Part Number
NHD-0216K1Z-FS(RGB)-FBW
Description
LCD MOD CHAR 2X16 RGB TRANSFL
Manufacturer
Newhaven Display
Series
NHD-0216K1Z-Fr
Datasheet

Specifications of NHD-0216K1Z-FS(RGB)-FBW

Display Type
FSTN - Film Super-Twisted Nematic
Display Mode
Transflective
Number Of Digits/alpha
32
Outline L X W X H
80.00mm x 36.00mm x 9.50mm
Viewing Area
64.50mm L x 16.40mm W
Display Format
16 x 2
Character Size
5.23mm H x 3.00mm W
Character Format
5 x 8 Dots
Voltage - Supply
5.0V
Dot Size
0.56mm W x 0.61mm H
Operating Temperature
-10°C ~ 50°C
Character Count X Line
16 x 2
Module Size (w X H X T)
80 mm x 36 mm x 13 mm
Features
RGB Backlight
Fluid Type
FSTN Positive
Voltage Rating
5 V
Operating Temperature Range
- 20 C to + 70 C
Backlight Type
LED RGB
Interface
Parallel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Backlight
-
Lead Free Status / Rohs Status
 Details
User’s Guide
NHD-0216K1Z-FS(RGB)-FBW
Newhaven Display International
RoHS Compliant
LCM
(Liquid Crystal Display Module)
K1Z
FS
RGB
F
B
W
= FSTN (+)
= 6:00 View Direction
= Wide Temperature (
= Transflective
= Product model / factory line
= Side B/L RED, GREEN, BLUE
For product support, contact
-20 ~ +70c
Newhaven Display International
2511 Technology Drive #101
Elgin, IL 60124
Tel: (847) 844-8795 Fax: (847) 844-8796
June 4, 2009
)
NHD-0216K1Z

Related parts for NHD-0216K1Z-FS(RGB)-FBW

NHD-0216K1Z-FS(RGB)-FBW Summary of contents

Page 1

... User’s Guide NHD-0216K1Z-FS(RGB)-FBW LCM (Liquid Crystal Display Module) RoHS Compliant K1Z = Product model / factory line FS = Transflective RGB = Side B/L RED, GREEN, BLUE F = FSTN (+) B = 6:00 View Direction W = Wide Temperature ( For product support, contact Newhaven Display International ) -20 ~ +70c Newhaven Display International ...

Page 2

... NHD-0216K1Z-FS(RGB)-FBW DOCUMENT REVISION HISTORY Version DATE 00 JAN-23-2006 CONTENTS Item Functions & Features Mechanical specifications Dimensional Outline Absolute maximum ratings Block diagram Pin description Contrast adjust Optical characteristics Electrical characteristics Timing Characteristics Instruction description Display character address code: character pattern Quality Specifications ...

Page 3

... NHD-0216K1Z-FS(RGB)-FBW 1. Features 1. 5x8 dots with cursor 2. Built-in controller (KS0066U or equivalent) 3. +5V power supply (also available for 3.0V version) 4. 1/16 duty cycle;1/5bias 5. BKL to be driven by pin1, pin2, or pin15, pin16 characters *2 lines display K1Z = Product model / factory line FS = Transflective RGB = Side B/L RED, GREEN, BLUE ...

Page 4

...

Page 5

Absolute maximum ratings Item Power voltage Input voltage Operating temperature range Storage temperature range 5. Block diagram 6. Interface pin description Pin no. Symbol connection GND Power supply R/W ...

Page 6

... NHD-0216K1Z-FS(RGB)-FBW 7. Contrast adjust V : LCD Driving voltage V DD~ 0 VR: 10k~20k 8. Optical characteristics TN type display module (Ta=25 , VDD=5.0V) Item Symbol Viewing angle Contrast ratio Response time (rise) Response time (fall) STN type display module (Ta=25 , VDD=5.0V) Item Symbol Viewing angle Contrast ratio ...

Page 7

... NHD-0216K1Z-FS(RGB)-FBW 10. Timing Characteristics Write cycle (Ta=25 , VDD=5.0V) Parameter Symbol Enable cycle time t c Enable pulse width t w Enable rise/fall time RS; R/W setup time t su1 RS; R/W address hold t h1 time Read data output delay t su2 Read data hold time t h2 Write mode timing diagram ...

Page 8

... NHD-0216K1Z-FS(RGB)-FBW Read cycle (Ta=25 , VDD=5.0V) Parameter Symbol Enable cycle time t c Enable pulse width t w Enable rise/fall time RS; R/W setup time t su RS; R/W address hold t h time Read data output delay t d Read data hold time t dh Read mode timing diagram ...

Page 9

... NHD-0216K1Z-FS(RGB)-FBW 11. Instruction description 11.1Outline To overcome the speed difference between the internal clock of KS0066U and the MPU clock, KS0066U performs internal operations by storing control in formations DR. The internal operation is determined according to the signal from MPU, composed of read/write and data bus (Refer to Table7). ...

Page 10

... NHD-0216K1Z-FS(RGB)-FBW to “Low”. 11.3Contents 1) Clear display RS R/W DB7 Clear all the display data by writing “20H” (space code) to all DDRAM address, and set DDRAM address to “00H” into AC (address counter). Return cursor to the original status, namely, bring the cursor to the left edge on the fist line of the display. ...

Page 11

... NHD-0216K1Z-FS(RGB)-FBW Note that display shift is performed simultaneously in all the lines. When display data is shifted repeatedly, each line is shifted individually. When display shift is performed, the contents of the address counter are not changed. Shift patterns according to S/C and R/L bits S/C R/L ...

Page 12

... NHD-0216K1Z-FS(RGB)-FBW The selection of RAM from DDRAM, and CGRAM, is set by the previous address set instruction (DDRAM address set, CGRAM address set). RAM set instruction can also determine the AC direction to RAM. After write operation. The address is automatically increased/decreased by 1, according to the entry mode. ...

Page 13

... NHD-0216K1Z-FS(RGB)-FBW 13. Standard character pattern Newhaven Display 13 2006-12-4 ...

Page 14

... NHD-0216K1Z-FS(RGB)-FBW 14. QUALITY SPECIFICATIONS 14.1 Standard of the product appearance test Manner of appearance test: The inspection should be performed in using 20W x 2 fluorescent lamps. Distance between LCM and fluorescent lamps should be 100 cm or more. Distance between LCM and inspector eyes should more. Viewing direction for inspection is 45° from vertical against LCM. ...

Page 15

... NHD-0216K1Z-FS(RGB)-FBW 14.2 Specification of quality assurance AQL inspection standard Sampling method: MIL-STD-105E, Level II, single sampling Defect classification (Note not including) Classify Major Display state Non-display Minor Display state Polarizer Soldering Wire TAB Item Short or open circuit LC leakage Flickering No display Wrong viewing direction ...

Page 16

... NHD-0216K1Z-FS(RGB)-FBW Note on defect classification No. Item 1 Short or open circuit LC leakage Flickering No display Wrong viewing direction Wrong Back-light 2 Contrast defect Background color deviation 3 Point defect, Black spot, dust (including Polarizer (X+Y)/2 Line defect, 4 Scratch 5 Rainbow Criterion Not allow Refer to approval sample Point ...

Page 17

... NHD-0216K1Z-FS(RGB)-FBW No Item 6 Chip Remark: X: Length direction Y: Short direction Z: Thickness direction t: Glass thickness W: Terminal Width Y W Criterion Acceptable criterion Acceptable criterion Acceptable criterion shall not reach to ITO X Acceptable criterion Y Disregard Z X Acceptable criterion Newhaven Display 0.5mm / 0.5mm 0 t/3 2006-12-4 ...

Page 18

... NHD-0216K1Z-FS(RGB)-FBW No. Item 7 Segment pattern W = Segment width I = (X+Y)/2 8 Back-light 9 Soldering 10 Wire 11* PCB Criterion (1) Pin hole I < 0.10mm is acceptable Point Size (1) The color of backlight should correspond to its specification. (2) Not allow flickering (1) Not allow heavy dirty and solder ball on PCB. (The size of dirty refer to point and dust defect) (2) Over 50% of lead should be soldered on Land ...

Page 19

... NHD-0216K1Z-FS(RGB)-FBW No Item 12 Protruded W: Terminal Width 13 TAB 1. Position 2 TAB bonding strength test 14 Total no. of acceptable A. Zone Defect B. Zone Criterion TAB P (=F/TAB bonding width) 650gf/cm ,(speed rate: 1mm/min) 5pcs per SOA (shipment) Maximum 2 minor non-conformities per one unit. Defect distance: each point to be separated over 10mm It is acceptable when trouble for quality and assembly in customer’ ...

Page 20

... NHD-0216K1Z-FS(RGB)-FBW 14.3 Reliability of LCM Reliability test condition: Item High temp. Storage High temp. Operating Low temp. Storage Low temp. Operating Humidity Temp. Cycle Recovery time should be 24 hours minimum. Moreover, functions, performance and appearance shall be free from remarkable deterioration within 50,000 hours under ordinary operating and storage conditions room temperature (20+8qC), normal humidity (below 65% RH), and in the area not exposed to direct sun light ...

Page 21

... NHD-0216K1Z-FS(RGB)-FBW 3. Do not touch the connection terminals of the display with bare hand; it will cause disconnection or defective insulation of terminals. 4. The modules should be kept in anti-static bags or other containers resistant to static for storage. 5. Only properly grounded soldering irons should be used electric screwdriver is used, it should be grounded and shielded to prevent sparks. ...

Related keywords