NHD-320240WG-COTFH-VZ#-010-80 Newhaven Display, NHD-320240WG-COTFH-VZ#-010-80 Datasheet - Page 11

LCD MOD GRAPHIC 320X240 TRANSFL

NHD-320240WG-COTFH-VZ#-010-80

Manufacturer Part Number
NHD-320240WG-COTFH-VZ#-010-80
Description
LCD MOD GRAPHIC 320X240 TRANSFL
Manufacturer
Newhaven Display

Specifications of NHD-320240WG-COTFH-VZ#-010-80

Display Type
FSTN - Film Super-Twisted Nematic
Display Mode
Transflective
Viewing Area
120.14mm L x 92.14mm W
Backlight
LED - White
Dot Size
0.34mm W x 0.34mm H
Dot Pitch
0.36mm x 0.36mm
Dot Pixels
320 x 240 (QVGA)
Interface
Parallel
Pixel Density
320 x 240
Fluid Type
FSTN Positive
Module Size (w X H X T)
154.7 mm x 120.2 mm x 15.6 mm
Backlighting
LED White
Operating Temperature Range
- 20 C to + 70 C
Product
Graphic LCD Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
NHD-320240WG-COTFH-VZ#-010-80
Manufacturer:
Newhaven Display Intl
Quantity:
135
10.RELIABILITY
Content of Reliability Test (wide temperature, -20
Note1: No dew condensation to be observed.
Note2: The function test shall be conducted after 4 hours storage at the normal
Note3: Vibration test will be conducted to the product itself without putting it in a container.
High Temperature storage
Low Temperature
storage
High Temperature
Operation
Low Temperature
Operation
High Temperature/
Humidity Operation
Thermal shock resistance
Vibration test
Static electricity test
Test Item
Temperature and humidity after remove from the test chamber.
Endurance test applying the high storage temperature for a long
time.
Endurance test applying the high storage temperature for a long
time.
Endurance test applying the electric stress (Voltage & Current)
and the thermal stress to the element for a long time.
Endurance test applying the electric stress under low temperature
for a long time.
The module should be allowed to stand at 60℃,90%RH max
For 96hrs under no-load condition excluding the polarizer,
Then taking it out and drying it at normal temperature.
The sample should be allowed stand the following 10 cycles of
operation
Endurance test applying the vibration during transportation and
using.
Endurance test applying the electric stress to the terminal.
-20℃
30min
Environmental Test
Content of Test
1 cycle
5min
第 11 頁,共 20 頁
25℃
30min
70℃
~70℃)
80℃
200hrs
-30℃
200hrs
70℃
200hrs
-20℃
200hrs
60℃,90%RH
96hrs
-20℃/70℃
10 cycles
Total fixed amplitude :
Vibration Frequency :
One cycle 60 seconds to 3
directions of X,Y,Z for
Each 15 minutes
VS=800V,RS=1.5kΩ
CS=100pF
1 time
15mm
10~55Hz
Test Condition
Note
——
——
——
1,2
1,2
2
1
3

Related parts for NHD-320240WG-COTFH-VZ#-010-80