Page 1
... NHD‐C12864HZ‐FN‐FBW COG (Chip‐On‐Glass) Liquid Crystal Display Module NHD‐ Newhaven Display C12864‐ 128 x 64 pixels HZ‐ Model F‐ ...
Page 2
Document Revision History Revision Date 0 1/29/2008 1 9/29/2009 2 10/13/2009 3 12/4/2009 4 3/10/2010 Functions and Features • 128 x 64 Pixels • Built‐in TL0324S controller • 3.0V Power Supply • 1/65 duty cycle; 1/9 bias • Parallel Interface • RoHS Compliant ...
Page 3
... Newhaven Display NHD-C12864HZ-FN-FBW 9/24/09 2/12/2007 ...
Page 4
Pin Description and Wiring Diagram Pin No. Symbol External Connection 1 VDD Power Supply 2 C86 MPU 3 VSS Power Supply 4 V0 Power Supply 5 V4 Power Supply 6 V3 Power Supply 7 V2 Power Supply 8 V1 Power Supply 9 C2‐ Power Supply 10 C2+ Power Supply 11 C1+ Power Supply 12 C1‐ ...
Page 5
Electrical Characteristics Item Operating Temperature Range Storage Temperature Range Supply Voltage Supply Current Supply for LCD (contrast) “H” Level input “L” Level input “H” Level output “L” Level output Optical Characteristics Item Viewing Angle ‐ Vertical Viewing Angle ‐ Horizontal Contrast Ratio Response Time (rise) Response Time (fall) Controller Information Built‐in TL0324S. Download specification at http://www.newhavendisplay.com/app_notes/TL0324S.pdf ...
Page 6
Write Timing: Read Timing: [6] ...
Page 7
Table of Commands [7] ...
Page 8
Quality Information Test Item High Temperature storage storage temperature for a long time. Low Temperature storage Endurance test applying the low storage temperature for a long time. High Temperature Endurance test applying the electric stress Operation (voltage & current) and the high thermal stress for a long time. Low Temperature Endurance test applying the electric stress Operation (voltage & current) and the low thermal stress for a long time. High Temperature / Endurance test applying the electric stress Humidity Operation (voltage & current) and the high thermal with high humidity stress for a long time. Thermal Shock resistance Endurance test applying the electric stress (voltage & current) during a cycle of low and high thermal stress. Vibration test Endurance test applying vibration to simulate transportation and use. Static electricity test Endurance test applying electric static discharge. Note 1: No condensation to be observed. Note 2: Conducted after 4 hours of storage at 25 Note 3: Test performed on product itself, not inside a container. ...