F-51900NCU-FW-AC Optrex America Inc, F-51900NCU-FW-AC Datasheet

no-image

F-51900NCU-FW-AC

Manufacturer Part Number
F-51900NCU-FW-AC
Description
LCD MOD GRAPH 320X240 COLOR
Manufacturer
Optrex America Inc
Series
F-51900r

Specifications of F-51900NCU-FW-AC

Display Type
LCD - Color
Display Mode
Transmissive
Viewing Area
120.00mm L x 90.00mm W
Backlight
CCFL - White
Dot Size
0.10mm W x 0.34mm H
Dot Pitch
0.12mm x 0.36mm
Dot Pixels
320 x 240 (QVGA)
Interface
Parallel
Pixel Density
320 x 240
Fluid Type
STN
Module Size (w X H X T)
168 mm x 111 mm x 9.4 mm
Viewing Area (w X H)
120 mm x 90 mm
Backlighting
CCFL White
Background Color
Black
Attached Touch Screen
No
Style
RGB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
73-1274
Rev.
Revision History
Type No.
Table of Contents
10. Precautions Relating Product Handling
11. Warranty
F-51900NCU-FW-AC (AC) No. 2004-0197
1. General Specifications
2. Electrical Specifications
3. Optical Specifications
4. I/O Terminal
5. Test
6. Appearance Standards
7. Code System of Production Lot
8. Type Number
9. Applying Precautions
LCD Module Technical Specification
Date
................................................................................................................................................................... 14
F-51900NCU-FW-AC
........................................................................................................................................................ 20
.................................................................................................................................................... 12
.................................................................................................................................................. 18
.................................................................................................................................. 18
................................................................................................................................. 10
.................................................................................................................................. 2
................................................................................................................................ 15
Page
............................................................................................................................... 3
............................................................................................................... 18
Comment
................................................................................................ 19
OPTREX CORPORATION
)
Approved by (Quality Assurance Division)
Prepared by (ACI Engineering Division)
Checked by (ACI Engineering Division)
)
M.Matsuura
First Edition
Final Revision
Dec 24, 2004
Page 1/20
******

Related parts for F-51900NCU-FW-AC

F-51900NCU-FW-AC Summary of contents

Page 1

... Test ................................................................................................................................................................... 14 6. Appearance Standards 7. Code System of Production Lot 8. Type Number .................................................................................................................................................. 18 9. Applying Precautions .................................................................................................................................. 18 10. Precautions Relating Product Handling 11. Warranty ........................................................................................................................................................ 20 Revision History Rev. Date F-51900NCU-FW-AC (AC) No. 2004-0197 .................................................................................................................................. 2 ............................................................................................................................... 3 ................................................................................................................................. 10 ................................................................................................................................ 15 ............................................................................................................... 18 ................................................................................................ 19 Page Comment OPTREX CORPORATION First Edition Dec 24, 2004 Final Revision ****** Approved by (Quality Assurance Division) ...

Page 2

... Weight : Viewing Angle : Data Transfer : Backlight : Drawings : F-51900NCU-FW-AC (AC) No. 2004-0197 min ~max min. -20 C ~max 320 × 3 [R.G.B] (W) × 240 (H) dots 0.1 (W) × 0.34 (H) mm 0.12 (W) × 0.36 (H) mm 120.0 (W) × 90.0 (H) mm (W) × 111.0 (H) × 9.4 max. ( 168.0 * Without CFL Cable 276g max ...

Page 3

... Supply Voltage V -V CC1 SS (Logic) Supply Voltage V vadj (LCD Drive) High Level V IH Input Voltage Low Level V IL Input Voltage Supply Current I CC1 F-51900NCU-FW-AC (AC) No. 2004-0197 Conditions Min. - -0.3 - -0.3 Conditions Min. - 4.5 2.5 - 1.5 V =5.0V 10% 0.8Vcc CC1 1 V =5.0V 10% ...

Page 4

... Parameter Applied Rating Voltage Resistance of Terminal Electrodes Linearity Insulation Resistance Surface Hardness Chattering Test condition : Touch screen is placed horionally in a vessel and no power is supplied to T/P. Normal state is temperatire : 2 relative humidity : F-51900NCU-FW-AC (AC) No. 2004-0197 Conditions - X Electrode Y Electrode - V =25V DC According to JIS-K5400 At connector Pin OPTREX CORPORATION Min ...

Page 5

... CP Fall Time Clock Pulse Rise/Fall Time Data Setup Time Data Hold Time DISPOFF Low Level Width DISPOFF Cancellation Time FLM Setup Time FLM Hold Time LP CP D0~D7 DISPOFF FLM F-51900NCU-FW-AC (AC) No. 2004-0197 Symbol Min. t 66/40 WCK t 23/12 WCKH t 23/14 WCKL t 30/15 ...

Page 6

... Timing Chart F-51900NCU-FW-AC (AC) No. 2004-0197 OPTREX CORPORATION Page 6/20 ...

Page 7

... Comparison of Display and Data F-51900NCU-FW-AC (AC) No. 2004-0197 OPTREX CORPORATION Page 7/20 ...

Page 8

... Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module. F-51900NCU-FW-AC (AC) No. 2004-0197 t=0 50ms t 20ms t 20ms t=0 50ms ...

Page 9

... The Average life time of CFL is defined as the time when half or more of the testing CFLs have become less bright than 50% of the initial brightness at continuous operation CFL Testing Circuit Recommended Inverter : TBD086N-4 CXA-L10L (DC 12.0V, Produced by TDK) F-51900NCU-FW-AC (AC) No. 2004-0197 Conditions Min. Typ 297 - 4 - ...

Page 10

... Panel at 1/A Duty - 1/B Bias (A: Duty Number, B: Bias Number). Driving voltage V is definded as follows (Vth1+Vth2 Vth1: The voltage V O-P luminance at the segment which the ON signal is applied to. Vth2: The voltage V O-P luminance at the segment which the OFF signal is applied to. Vo-p 1 SIGNAL ) F-51900NCU-FW-AC (AC) No. 2004-0197 Ta=25 C, 1/240 Duty, 1/13 Bias, V Conditions OFF / L ) OFF ...

Page 11

... Definition of Viewing Angle and Optimum Viewing Area *Driving condition: 1/240 Duty, 1/13Bias =L:46 R:42 = F:20 R:37 3.3. System Block Diagram Photometer #1980A WB Computer F-51900NCU-FW-AC (AC) No. 2004-0197 22.5V Temperature Chamber Rotation Table ( , ) Control Unit & Waveform Generator OPTREX CORPORATION = 70Hz F LCD ...

Page 12

... CN3 No. Symbol LEVEL 1 DOWN 2 LEFT RIGHT F-51900NCU-FW-AC (AC) No. 2004-0197 Display Data Display Control Signal H : Display Display off First Line Marker Data Latch Signal Clock Signal for Shifting Data Alternate Signal for LCD Drive - Power Supply for LCD Drive - Power Supply (0V, GND) - ...

Page 13

... It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. MODULE 4.3. Block Diagram FLM LP DISPOFF CP D0~D7 M VCC2 DC/DC Circuit V VADJ V SS VCC1 VCFL GND F-51900NCU-FW-AC (AC) No. 2004-0197 3. VADJ VR R2 VSS VSS V V CC1 CC1 V V CC2 CC2 ...

Page 14

... Note 2 :The function test shall be conducted after 4 hours storage at the normal Temperature and humidity after removed from the test chamber. Note 3 :Vibration test will be conducted to the product itself without putting container. F-51900NCU-FW-AC (AC) No. 2004-0197 Conditions 96hrs (operation state 96hrs (operation state) ...

Page 15

... All directions for inspecting the sample should be within 45 against perpendicular line. 6.2. Definition of applicable Zones A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area F-51900NCU-FW-AC (AC) No. 2004-0197 45 A Zone Bezel Flame B Zone C Zone ...

Page 16

... If the stains are removed easily from LCDP surface, the module is not 5 Polarizer Dirts defective. Conplex Foreign Black 6 Substabce Defects between glass&polarizer shoud be 5pcs maxmum in total. Distance between D 7 Different Forrein 0.2< 40mm or more Substabce Defects F-51900NCU-FW-AC (AC) No. 2004-0197 Criteria Zone A Dimension (mm) D 0.1 * 0.1 < D 0.2 3 0.2 < D 0.25 2 0.25< D ...

Page 17

... No. Parameter 8 Black and Judge at the voltage which can be seen easily defect mode. White Spots With Gray Scale F-51900NCU-FW-AC (AC) No. 2004-0197 Criteria Zone Dimension (mm) D 0.3 0.3 < D 0.6 OPTREX CORPORATION Acceptable Number Disregard 3 (1pc within 30mm) Page 17/20 ...

Page 18

... Type Number The type number of module is specified as follows. F-51900NCU-FW-AC 9. Applying Precautions Please contact us when questions and/or new problems not specified in this Specifications arise. F-51900NCU-FW-AC (AC) No. 2004-0197 Factory Control Number (0~99) Date of the week (A~G) Factory Number (0~9) Factory Code (Alphabet) OPTREX CORPORATION ...

Page 19

... Be sure to protect the rear of the IC chip from external forces. 2. Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact. F-51900NCU-FW-AC (AC) No. 2004-0197 OPTREX CORPORATION Page 19/20 ...

Page 20

... Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe delivery which ever comes later. F-51900NCU-FW-AC (AC) No. 2004-0197 OPTREX CORPORATION Page 20/20 ...