NHD-24064WG-ATFH-VZ#000CB Newhaven Display, NHD-24064WG-ATFH-VZ#000CB Datasheet

LCD MOD GRAPH 240X64 WH TRANSFL

NHD-24064WG-ATFH-VZ#000CB

Manufacturer Part Number
NHD-24064WG-ATFH-VZ#000CB
Description
LCD MOD GRAPH 240X64 WH TRANSFL
Manufacturer
Newhaven Display
Series
NHD-24064WG-Ar

Specifications of NHD-24064WG-ATFH-VZ#000CB

Display Type
LCD - Monochrome
Display Mode
Transflective
Viewing Area
133.00mm L x 39.00mm W
Backlight
LED - White
Dot Size
0.49mm W x 0.49mm H
Dot Pitch
0.53mm x 0.53mm
Dot Pixels
240 x 64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
User’s Guide
NHD-24064WG-ATFH-VZ#000CB
LCM
NHD-
24064-
WG-
A -
T-
F-
H-
VZ#-
000CB-
(Liquid Crystal Display Graphic Module)
RoHS Compliant
Newhaven Display
240 x 64 pixels
W= Factory Line G= Display Type: Graphic
Model / Serial number
White LED B/L
FSTN (+)
Transflective, 6:00 View, Wide Temperature (-20 ~ +70c)
With Built-in Negative Voltage; RoHS
Custom Version: 2x10 Interface Header: Molex p/n 10-89-7202 or equiv.
For product support, contact
Newhaven Display International
2511 Technology Drive, #101
Elgin, IL 60124
Tel: (847) 844-8795 Fax: (847) 844-8796
February 29, 2008

Related parts for NHD-24064WG-ATFH-VZ#000CB

NHD-24064WG-ATFH-VZ#000CB Summary of contents

Page 1

... User’s Guide NHD-24064WG-ATFH-VZ#000CB LCM (Liquid Crystal Display Graphic Module) RoHS Compliant Newhaven Display NHD- 240 x 64 pixels 24064- WG- W= Factory Line G= Display Type: Graphic A - Model / Serial number White LED B/L T- FSTN (+) F- Transflective, 6:00 View, Wide Temperature (-20 ~ +70c) H- With Built-in Negative Voltage; RoHS VZ#- Custom Version: 2x10 Interface Header: Molex p/n 10-89-7202 or equiv ...

Page 2

... Contents 1.Module Classification Information 2.Precautions in use of LCD Modules 3.General Specification 4.Absolute Maximum Ratings 5.Electrical Characteristics 6.Optical Characteristics 7.Interface Description 8.Contour Drawing 9. Display Control Instruction 10.Timing Characteristics 11. Quality Assurance 12. Reliability 13.Backlight Information Newhaven Display International, LLC Block Diagram NHD-24064WG-ATFH-VZ#000-CB 2 ...

Page 3

... Classification Information NHD 24064 Brand Newhaven Display d Display Font 240 x 64 Dots e Factory Line Display Type H Character Type, G Graphic Type Model / Serial number Backlight Type N Without backlight B EL, Blue green D EL, Green W EL, White F CCFL, White Y LED, Yellow Green i LCD Mode ...

Page 4

... Character pitch LCD type FSTN(+), Transflective Duty 1/64 View direction 6 o’clock Backlight Type LED White Newhaven Display International, LLC NHD-24064WG-ATFH-VZ# Dimension 240 x 64dots 180.0 x 65.0 x 12.3(MAX) 133.0 x 39.0 127.16 x 33.88 0.48 x 0.48 0.52 x 0.52 0.49 x 0.49 0.53 x 0.53 NHD-24064WG-ATFH-VZ#000-CB 4 Unit ...

Page 5

... Supply Voltage For LCD Input High Volt. Input Low Volt. Output High Volt. Output Low Volt. Supply Current Newhaven Display International, LLC Symbol Min Vss -0 Symbol Condition Min Ta=0 Ta= Ta=+50 11 Typ Max Unit +70 + Typ Max Unit 5.25 V 13 NHD-24064WG-ATFH-VZ#000-CB ...

Page 6

... T fall Definition of Response Time ( Non-selected Selected Wave Conition Intensity Non-selected Wave Cr = Lon / Loff 100 Driving Voltage(V) Viewing Angle( Driving Waveform : 1/N duty , 1/a bias Typ Max Unit 105 deg 30 deg 3 150 200 ms 150 200 ms Non-selected Selected Conition Conition [Negative type NHD-24064WG-ATFH-VZ#000-CB ...

Page 7

... RD=L , C/D=H : Status Read C/D=L: Data read Negative voltage –10V output H : Normal ; L : Initialize T6963C Data bus line Data bus line Data bus line Data bus line Data bus line Data bus line Data bus line Data bus line Pins for selection of font connection NHD-24064WG-ATFH-VZ#000-CB 7 ...

Page 8

... SCALE 10/1 NHD-24064WG-ATFH-VZ#000- 4.13 6 12.3Max 2.54 1.6 20- 1.0 PTH LED B/L 20- 1.8 PAD mm Newhaven Display Intl., LLC 1/1 0 1/2 NHD-24064WG-ATFH-VZ#000-CB LCM DRAWING Nina 07/11/07' TLM-960708 FGND Vss Vdd C/D Vee RESET DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 FS NC ...

Page 9

... Interface The external RAM is used to store display data ( text, graphic and external CG data ). It can be freely allocated to the memory area ( 8 K byte max ). Recommend 0000H 0C00H 1800H 2000H Newhaven Display International, LLC TEXT AREA GRAPHIC AREA CG RAM AREA NHD-24064WG-ATFH-VZ#000-CB 9 ...

Page 10

... STA2 and STA3 are valid in Auto mode; STA0 and STA1 are invalid. Status Checking flow Newhaven Display International, LLC STA4 STA3 STA2 0:Disable 1:Enable 0:Disable 1:Enable 0:Disable 1:Enable 0:Disable 1:Enable 0:Disable 1:Enable 0:No error 1:Error 0:Disable off 1:Normal display NHD-24064WG-ATFH-VZ#000-CB 10 LSB STA1 STA0 D1 D0 ...

Page 11

... Setting date When using the T6963C, first set the data, then set the command. Procedure for sending a command (a)The case of 1 date Newhaven Display International, LLC (b) (b)The case of 2 data NHD-24064WG-ATFH-VZ#000-CB 11 ...

Page 12

... EXOR mode AND mode Text Attribute mode Internal CG ROM mode External CG RAM mode Display off Cursor on, blink off Cursor on, blink on Text on, graphic off Text off, graphic on Text on, graphic on 1-line cursor 2-line cursor 3-line cursor 4-line cursor 5-line cursor 6-line cursor NHD-24064WG-ATFH-VZ#000-CB 12 FUNCTION ...

Page 13

... Write and Non-variable ADP Data Read and Non-variable ADP Screen Peek D1 D2 FUNCTION Screen Copy Bit Reset Bit Set Bit 0 (LSB) Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 (MSB ADRS DATA LOW ADRS HIGH ADRS NHD-24064WG-ATFH-VZ#000- invalid X: invalid D2 Y ADRS 00H ...

Page 14

... The relationship between display RAM address and offset register Offset register data 00000 00001 00010 11100 11101 11110 11111 (Example 1) Newhaven Display International, LLC CG RAM hex. address (start to end) 0000 to 07 FFH 0800 to 0FFFH 1000 to 17FFH E000 to E7FFH E800 to EFFFH F000 to F7FFH F800 to FFFFH NHD-24064WG-ATFH-VZ#000-CB 14 ...

Page 15

... RAM. (3) Set Address Pointer The Set Address Pointer command is used to indicate the start address for writing to (or reading from) external RAM. The Flowchart for Set Address Pointer command Newhaven Display International, LLC 02H 80H 0001 0100 0000 0000 NHD-24064WG-ATFH-VZ#000-CB 15 ...

Page 16

... The starting address in the external display RAM for text display is defined by this command. The text home address indicates the leftmost and uppermost position. Newhaven Display International, LLC (upper 8 bits) D1 Low address Columns Low address Columns NHD-24064WG-ATFH-VZ#000- High address 00H High address 00H ...

Page 17

... GH: Graphic home address GA: Graphic area number (columns) CL: Columns are fixed by hardware (pin-programmable). Newhaven Display International, LLC TH+CL TH+TA+CL TH+2TA+CL TH+3TA+CL TH+(n-1) TA+CL 0000H 0020H 32 Columns 4 Lines 001EH 003EH 005EH 007EH GH+GL GH+GA+CL GH+2GA+CL GH+3GA+CL GH+(n-1) GA+CL NHD-24064WG-ATFH-VZ#000-CB 17 001FH 002FH 005FH 007FH ...

Page 18

... Newhaven Display International, LLC 0000H 0020H 32 Columns 2 Lines 001EH 003EH 005EH 007EH 009EH 00BEH 00DEH 00FEH 011EH 013EH 015EH 017EH 109EH 01BEH 01DEH 01FEH 20 columns, 4lines 0000H NHD-24064WG-ATFH-VZ#000-CB 18 001FH 003FH 005FH 007FH 009FH 00BFH 00DFH 00FFH 011FH 013FH 014FH 017FH 019FH 01BFH 01DFH 01FFH ...

Page 19

... If the graphic area setting is set to match the desired number of columns on the LCD, the addressing scheme will be automatically modified so that the start address of each line equals the end address of the previous line +1. Newhaven Display International, LLC 0014H 0013 0014 0027 0028 003B 003C 004F 0050 20 columns, 2lines 0000H 0014H NHD-24064WG-ATFH-VZ#000-CB 19 001F 0033 0047 005B ...

Page 20

... Set Control Word command. Only text display is possible in Attribute Function mode; graphic display is automatically disabled. However, the Display Mode command must be used to turn both Text and Graphic on in order for Newhaven Display International, LLC OPERAND X: invalid NHD-24064WG-ATFH-VZ#000-CB 20 ...

Page 21

... Cursor on, blink off 1001xx11 Cursor on, blink on 100101xx Text on, graphic off 100110xx Text off, graphic on 100111xx Text on, graphic on Newhaven Display International, LLC d3 FUNCTION Normal display Reverse display Inhibit display Blink of normal display Blink of reverse display Blink of inhibit display X: invalid OPERAND NHD-24064WG-ATFH-VZ#000- invalid ...

Page 22

... When cursor display is ON, this command selects the cursor pattern in the range 1 line to 8 lines. The cursor address is defined by the Cursor Pointer Set command. Newhaven Display International, LLC OPERAND NHD-24064WG-ATFH-VZ#000-CB 22 ...

Page 23

... The Auto Reset command must be sent to the T69963C after all data has been sent, to clear Auto mode. (Note) A Status check for Auto mode (STA2, STA3 should be checked between sending of each datum. Auto Reset should be performed after checking STA3=1 (STA2=1.) Refer to the following flowchart. a) Auto Read mode Newhaven Display International, LLC FUNCTION OPERAND b) Auto Write mode NHD-24064WG-ATFH-VZ#000-CB 23 ...

Page 24

... Newhaven Display International, LLC 24 NHD-24064WG-ATFH-VZ#000-CB ...

Page 25

... Newhaven Display International, LLC 25 NHD-24064WG-ATFH-VZ#000-CB ...

Page 26

... RAM to the MPU. Data Write/Data Read should be executed after setting address using Set Address Pointer command. The address pointer can be automatically incremented or decremented using this command. (Note) This command is necessary for each 1-byte datum. Refer to the following flowchart. Newhaven Display International, LLC 26 OPERAND Data Data Data NHD-24064WG-ATFH-VZ#000-CB ...

Page 27

... The status (STA6) should be checked just after the Screen Peek command. If the address determined by the Set Address Pointer command is not in the graphic area, this commands is ignored and a status flag (STA6) is set. Refer to the following flowchart. Newhaven Display International, LLC 27 OPERAND e NHD-24064WG-ATFH-VZ#000-CB ...

Page 28

... This command copies a single raster line of data to the graphic area. The start point must be set using the Set Address Pointer command. (Note 1) If the attribute function is being used, this command is not available. (With Attribute data is graphic area data.) Refer to the following flowchart. Newhaven Display International, LLC 28 OPERAND NHD-24064WG-ATFH-VZ#000-CB ...

Page 29

... Bit Set/Reset CODE FUNCTION 11110xxx Bit Reset Bit Set 11111xxx Newhaven Display International, LLC OPERAND NHD-24064WG-ATFH-VZ#000-CB 29 ...

Page 30

... Bit 3 1111x100 Bit 4 1111x101 Bit 5 1111x110 Bit 6 1111x111 Bit 7 (MSB) This command is used to set or reset a bit of the byte specified by the address pointer. Only one bit can be set/reset at a time. Refer to the following flowchart. Newhaven Display International, LLC 30 X: invalid NHD-24064WG-ATFH-VZ#000-CB ...

Page 31

... Newhaven Display International, LLC 31 NHD-24064WG-ATFH-VZ#000-CB ...

Page 32

... C/D Hold Time CE, RD, WR Pulse Width Data Set-up Time Data Hold Time Access Time Output Hold Time C/D CE RD, WRITE READ) Newhaven Display International, LLC Symbol Min Typ t 100 CDS t 10 CDH CDS ACC CDS CDH ACC NHD-24064WG-ATFH-VZ#000-CB 32 Max Unit 150 ...

Page 33

... B) Unclear Size Acceptable Qty in active area d 0.2 Disregard 0.2<d 0.5 0.5<d 0.7 0.7<d Size Acceptable Qty in active area d 0.3 Disregard 0.3<d 1.0 1.0<d 1.5 1.5<d remarkable. other. LCD panels. only. 33 Partition Minor Minor 1 0 Minor Minor Minor NHD-24064WG-ATFH-VZ#000-CB ...

Page 34

... Total 0.5hrs 50G Half sign wave 11 msedc 3 times of each direction 115mbar 40hrs VS=800V,RS=1.5k CS=100pF 1 time 34 Applicable Standard —— —— —— —— —— —— —— Mechanical Test —— —— —— —— NHD-24064WG-ATFH-VZ#000-CB ...

Page 35

... Supply voltage for LCD system =Operating voltage at 25 13.Backlight Information Specification PARAMETER SYMBOL MIN Supply Current ILED Supply Voltage V Reverse Voltage VR Luminous IV Intensity Life Time Color WHITE Newhaven Display International, LLC TYP MAX UNIT 80 100 125 mA 3.4 3.5 3 180 220 CD/M 50,000 Hr. NHD-24064WG-ATFH-VZ#000-CB 35 TEST CONDITION V=3.5V 2 ILED=100mA V 3.6V ...