VK202-25-VPT Matrix Orbital, VK202-25-VPT Datasheet - Page 41

no-image

VK202-25-VPT

Manufacturer Part Number
VK202-25-VPT
Description
VFD ALPHA/NUM DISPLAY 20X2
Manufacturer
Matrix Orbital
Series
VK202-25r
Datasheet

Specifications of VK202-25-VPT

Outline L X W X H
116.00mm x 37.00mm x 29.48mm
Viewing Area
89.75mm L x 11.50mm W
Display Format
20 x 2
Display Type
Character
Format
5 x 7 Dots
Voltage - Supply
9 V ~ 35 V
Character Size
4.70mm H x 2.40mm W
Interface
Serial
Operating Temperature
-20°C ~ 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Dots
-
9.6 Set Debounce Time
9.7 Set Auto Repeat Mode
Matrix Orbital
Description
Remembered
Syntax
Parameters
Description
Remembered
Default
Syntax
Parameters
This command clears any unread key presses. In a menu application, if
the user presses a key which changes the menu context, any following
key presses may be inaccurate and can be cleared out of the buffer
between menu changes to prevent jumping around the menu tree. It may
also be used, in effect, to reset the keypad in case the host application
resets for whatever reason.
No
This command sets the time between key press and key read. All key
types with the exception of latched piezo switches will ’bounce’ for a
varying time, depending on their physical characteristics. The [time]
value is in increments of 6.554ms. The default debounce time for the
module is 8 (about 52ms), which is adequate for most membrane
keypads.
Yes
8
Hexadecimal
Decimal
ASCII
Parameter
time
Hexadecimal
Decimal
ASCII
Parameter
mode
0xFE 0x55 [time]
254 85 [time]
254 “U” [time]
0xFE 0x7E [mode]
254 126 [mode]
254 “~” [mode]
VK202-25
Length
Length
1
1
Description
Debounce time in increments of
6.554ms (0 - 255).
Description
Auto Repeat Mode (0: Resend Key
, 1: Key Up/Down)
37