AFCT-701SDZ Avago Technologies US Inc., AFCT-701SDZ Datasheet - Page 13

TXRX SFP+ SMF 10BGD 1310NM

AFCT-701SDZ

Manufacturer Part Number
AFCT-701SDZ
Description
TXRX SFP+ SMF 10BGD 1310NM
Manufacturer
Avago Technologies US Inc.
Series
-r
Datasheet

Specifications of AFCT-701SDZ

Data Rate
10.312Gbd
Wavelength
1310nm
Applications
Ethernet
Voltage - Supply
3.135 V ~ 3.465 V
Connector Type
LC Duplex
Mounting Type
SFP
For Use With Fiber Type
Multimode
Function
SFP+ 10 Gb ethernet transceiver
Maximum Forward Current
289 mA
Maximum Power Dissipation
1000 mW
Transmission Distance
10 Km
Product
Transceiver
Diode Capacitance
14 pF
Maximum Rise Time
28 ps
Maximum Fall Time
28 ps
Maximum Output Current
20 mA
Operating Supply Voltage
3.465 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Supply Voltage
3.3V
Wavelength Typ
1310nm
Leaded Process Compatible
Yes
Peak Reflow Compatible (260 C)
Yes
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
Multimode Glass
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AFCT-701SDZ
Manufacturer:
Avago Technologies
Quantity:
135
Company:
Part Number:
AFCT-701SDZ
Quantity:
126
Table 9. Control Functions: Low Speed Signals Timing Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Parameter
TX_DISABLE Assert Time
TX_DISABLE Negate Time
Time to initialize, including reset of TX_FAULT
TX_FAULT Assert Time
TX_DISABLE to Reset
RX_LOS Assert Time
RX_LOS Deassert Time
Notes:
1. Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal. A 10 ms interval between assertions of TX_
2. Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal.
3. Time from power on or falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal and the Two-Wire
4. From power on or negation of TX_FAULT using TX_DISABLE.
5. Time TX_DISABLE must be held high to reset the laser fault shutdown circuitry.
6. Time from loss of optical signal to Rx_LOS Assertion.
7. Time from valid optical signal to Rx_LOS De-Assertion.
Table 10. Control Functions: Two-Wire Interface Timing Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Parameter
TX_DISABLE Assert Time
TX_DISABLE Negate Time
TX_FAULT Assert Time
Rx_LOS Assert Time
Rx_LOS Deassert Time
Analog parameter data ready
Two-Wire Interface Ready
Complete Single or Sequential Write up to 4 Byte t_write
Complete Sequential Write of 5-8 Byte
Two-Wire Interface Clock Rate
Time bus free before new
transmission can start
1. Time from two-wire interface assertion of TX_DISABLE (A2h, byte 110, bit 6) to when the optical output falls below 10% of nominal. Measured
2. Time from two-wire interface de-assertion of TX_DISABLE (A2h, byte 110, bit 6) to when the modulated optical output rises above 90% of
3. Time from fault to two-wire interface TX_FAULT (A2h, byte 110, bit 2) asserted.
4. Time for two-wire interface assertion of Rx_LOS (A2h, byte 110, bit 1) from loss of optical signal.
5. Time for two-wire interface de-assertion of Rx_LOS (A2h, byte 110, bit 1) from presence of valid optical signal.
6. From power on to data ready bit asserted (A2h, byte 110, bit 0). Data ready indicates analog monitoring circuitry is functional.
7. Time from power on until module is ready for data transmission over the two-wire interface (reads or writes over A0h and A2h).
8. Operation of the Two Wire Serial Interface at rtes beyond 100kHz requires the use of clock stretching techniques.
9. Between STOP and START. See SFF 8431 Section 4.3
13
DISABLE is required.
interface is available.
from falling clock edge after stop bit of write transaction.
nominal.
Symbol
t_off_twi
t_on_twi
t_fault_twi
t_loss_on_twi
t_loss_off_twi
t_data
t_serial
t_write
f_serial_clock
t_BUF
Symbol
t_off
t_on
t_init
t_fault
t_reset
t_los_on
t_los_off
Minimum
10
Minimum
20
Maximum
100
2
300
1000
100
100
Maximum
100
100
100
100
100
1000
300
40
80
400
Unit
µs
ms
ms
µs
µs
µs
µs
Unit
ms
ms
ms
ms
ms
ms
ms
ms
ms
kHz
ms
Notes
Note 1 , Fig. 6
Note 2 , Fig. 6
Note 3 , Fig. 6
Note 4 , Fig. 6
Note 5 , Fig. 6
Note 6 , Fig. 6
Note 7 , Fig. 6
Notes
Note 1
Note 2
Note 3
Note 4
Note 5
Note 6
Note 7
Note 8
Note 8
Note 8
Note 9