LUW W5AM-KXKZ-5F8G-Z OSRAM Opto Semiconductors Inc, LUW W5AM-KXKZ-5F8G-Z Datasheet

LED DRAGON PLUS ULTRAWHITE

LUW W5AM-KXKZ-5F8G-Z

Manufacturer Part Number
LUW W5AM-KXKZ-5F8G-Z
Description
LED DRAGON PLUS ULTRAWHITE
Manufacturer
OSRAM Opto Semiconductors Inc
Series
Golden DRAGON® Plusr
Type
Uni-Colorr
Datasheet

Specifications of LUW W5AM-KXKZ-5F8G-Z

Viewing Angle
170°
Package / Case
0.28" L x 0.24" W x 0.04" H (7mm x 6mm x 1mm)
Color
White, Cool
Current - Test
350mA
Luminous Flux @ Current - Test
91.5lm
Current - Max
1A
Lumens @ Current - Max
204lm
Lumens/watt @ Current - Test
82lm/W
Voltage - Forward (vf) Typ
3.2V
Wavelength
6500K
Lens Style/size
Round, 4.2mm
Mounting Type
Surface Mount
Illumination Color
Ultra White
Luminous Intensity
26100 mcd
Power Rating
3.8 W
Operating Voltage
3.2 V
Operating Current
350 mA
Minimum Operating Temperature
- 40 C
Maximum Operating Temperature
+ 125 C
Led Size
5 mm x 5 mm x 1.2 mm
Lens Appearance
Non-Diffused
Lens Shape
Dome
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
876-1003 - LM3406 LED DRIVER EVAL BOARD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
475-2598-1
Golden DRAGON
Lead (Pb) Free Product - RoHS Compliant
LUW W5AM
Vorläufige Daten / Preliminary Data
Besondere Merkmale
• Gehäusetyp: weißes SMD Gehäuse, klarer
• Typischer Lichtstrom: 105 lm bei 350 mA
• Besonderheit des Bauteils: hocheffiziente
• Farbort: x = 0,31, y = 0,32 nach CIE 1931 (weiß)
• typische Farbtemperatur: 6500 K
• Abstrahlwinkel: 170°
• Technologie: ThinGaN
• optischer Wirkungsgrad: 93 lm/W
• Gruppierungsparameter: Lichtstrom, Farbort
• Verarbeitungsmethode: für alle
• Lötmethode: IR Reflow Löten
• Vorbehandlung: nach JEDEC Level 4
• Gurtung: 24-mm Gurt mit 200/Rolle, ø180 mm
• ESD-Festigkeit: ESD-sicher bis 2 kV nach
Anwendungen
• Blitzlicht
• Hinterleuchtung (Werbebeleuchtung,
• Leseleuchten
• Ersatz von Kleinst-Glühlampen
• Fassadenbeleuchtung im Innen- und Außenbereich
• Display Hinterleuchtung mit hohem
• Dekorative Beleuchtung
• Signal- und Symbolleuchten zur Orientierung
• Markierungsbeleuchtung (Stufen, Fluchtwege, u.ä.)
• Straßenbeleuchtung
• Tunnelbeleuchtung
• Deckenleuchten
2008-08-26
Silikon - Verguss, klare Silikonlinse, Chip level
conversion
Lichtquelle bei geringem Platzbedarf
SMT-Bestücktechniken geeignet
JESD22-A114-D
Allgemeinbeleuchtung)
Helligkeitsbedarf
®
Plus with Chip Level Conversion (CLC)
®
1
Features
• package: white SMD package, colorless clear
• typical Luminous Flux: 105 lm at 350 mA
• feature of the device: high efficient lightsource
• color coordinates: x = 0.31, y = 0.32 acc. to
• typ. color temperature: 6500 K
• viewing angle: 170°
• technology: ThinGaN
• optical efficiency: 93 lm/W
• grouping parameter: luminous flux,
• assembly methods: suitable for all
• soldering methods: IR reflow soldering
• preconditioning: acc. to JEDEC Level 4
• taping: 24 mm tape with 200/reel, ø180 mm
• ESD-withstand voltage: up to 2 kV acc. to
Applications
• Flashlight
• backlighting (illuminated advertising, general
• reading lamps
• substitution of micro incandescent lamps
• indoor and outdoor commercial and residential
• display backlight where high brightness is required
• decorative and entertainment lighting
• signal and symbol luminaire for orientation
• marker lights (e.g. steps, exit ways, etc.)
• street lighting
• tunnel lighting
• ceiling light
silicone resin, clear silicone lens, chip level
conversion
at low space
CIE 1931 (white)
color coordinates
SMT assembly methods
JESD22-A114-D
lighting)
architectural lighting
®

Related parts for LUW W5AM-KXKZ-5F8G-Z

LUW W5AM-KXKZ-5F8G-Z Summary of contents

Page 1

... Golden DRAGON Plus with Chip Level Conversion (CLC) Lead (Pb) Free Product - RoHS Compliant LUW W5AM Vorläufige Daten / Preliminary Data Besondere Merkmale • Gehäusetyp: weißes SMD Gehäuse, klarer Silikon - Verguss, klare Silikonlinse, Chip level conversion • Typischer Lichtstrom: 105 lm bei 350 mA • ...

Page 2

... Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LUW W5AM-KXKZ-5P7R means that only one group KX, KYor KZ will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. ...

Page 3

... Junction/solder point 2008-08-26 Symbol Wert Symbol Value T – 40 … + 110 op T – 40 … + 110 stg T 125 j I (min.) 100 F I (max.) 1000 F I 2000 FM V not designed for R reverse operation P 3.8 tot (max LUW W5AM Einheit Unit °C °C ° K/W ...

Page 4

... Symbol 5) Seite 20 (typ page 20 5) Seite 20 (typ page 20 ϕ (typ (min (typ (max (max.) R η (typ.) opt 4 LUW W5AM Wert Einheit Value Unit 0.31 – 0.32 – 170 Grad deg. 2.7 V 3.2 V 3.8 V not designed for μ reverse operation A 93 lm/W ...

Page 5

... Gruppe Cx Group 5R 0.289 0.287 0.304 0.305 6R 0.305 0.304 0.317 0.317 7R 0.317 0.322 0.330 0.334 LUW W5AM OHA03489 Cy 0.291 0.296 0.329 0.322 0.322 0.329 0.356 0.346 0.356 0.365 0.373 0.365 ...

Page 6

... LUW W5AM OHA03633 Cy 0.324 0.332 0.338 0.331 0.332 0.339 0.346 0.338 0.339 0.346 0.354 0.346 0.346 0.354 0.362 0.354 0.331 0.338 ...

Page 7

... LUW W5AM Cx Cy 0.329 0.338 0.329 0.346 0.337 0.353 0.337 0.345 0.329 0.346 0.329 0.354 0.338 0.362 0.337 0.353 0.329 0.354 ...

Page 8

... Seite 20 Lichtstrom 1) page 20 Luminous Flux Φ (mlm) V 71.000 ... 82.000 82.000 ... 97.000 97.000 ...112.000 112.000 ...130.000 130.000 ...150.000 Farbortgruppe Chromaticity Coordinate Group 5P 8 LUW W5AM 2) Seite 20 Lichtstärke 2) page 20 Luminous Intensity I (mcd) V 19.100 (typ.) 22.400 (typ.) 26.100 (typ.) 30.200 (typ.) 35.000 (typ.) ...

Page 9

... Seite 20 2) page 20 500 550 30˚ 20˚ 10˚ 0˚ 1.0 0.8 0.6 0.4 0.2 0 0.6 0.4 0˚ λ 600 650 700 20˚ 40˚ 60˚ 80˚ 100˚ LUW W5AM OHL13926 nm 750 λ OHL03635 120˚ ...

Page 10

... F A 0.025 Δ Δ Cx 0.015 0.010 Cx 0.005 0 -0.005 -0.010 -0.015 0 100 200 300 400 500 600 2008-08-26 Relative Lichtstrom Relative Luminous Flux Φ V OHL02520 3.5 4 page 20 OHL02805 mA 800 Seite page 20 / Φ °C (350 mA Φ V Φ V (350 mA LUW W5AM OHL02726 ...

Page 11

... Seite 20 Relative Lichtstrom Relative Luminous Flux Φ 350 OHL02671 60 ˚C 100 page 20 OHL03444 60 80 100 ˚C 140 Seite 20 2) page 20 / Φ 350 mA (25 ° 1.4 Φ V Φ V (25 ˚C) 1.0 0.8 0.6 0.4 0.2 0 -60 -40 - LUW W5AM OHL12725 40 60 ˚C 100 T j ...

Page 12

... OHL02948 80 100 ˚C 140 T S Zulässige Impulsbelastbarkeit Permissible Pulse Handling Capability Duty cycle = 25 °C S OHL03757 0.005 0.01 0.02 0.033 0.05 0 parameter ° 2.0 1.5 0.2 1.0 0 LUW W5AM OHL03758 0.005 0.01 0.02 0.033 0.05 0 ...

Page 13

... Seite 20 8) page 20 4 (0.157) ±0.1 (0.004) 2 (0.079) ±0.1 (0.004) 6.35 (0.250) 12 (0.472) ±0.1 (0.004) 13 Markierung mark 200 mg Verpackungseinheit 200/Rolle, ø180 mm Packing unit 200/reel, ø180 mm 0.3 (0.012) ±0.05 (0.002) 3.2 (0.126) ±0.1 (0.004) 0.3 (0.012) ±0.1 (0.004) LUW W5AM ±0.1 (0.004) OHAY3636 ...

Page 14

... Lötstellen Thermisch optimiertes PCB 3 solder points Thermal enhanced PCB 11.6 (0.457) 1.6 (0.063) 12.0 (0.472) 11.6 (0.457) Kupfer Copper 14 LUW W5AM ø4.0 (0.157) Heatsink attach Lötstopplack Solder resist Lötpasten Schablone Solder paste stencil 1.6 (0.063) Freies Kupfer 1 (0.039) Bare Copper ...

Page 15

... Vorbehandlung nach JEDEC Level 4 Preconditioning acc. to JEDEC Level 4 (nach J-STD-020B) (acc. to J-STD-020B) Maximum Solder Profile Recommended Solder Profile Minimum Solder Profile 120 s max 100 150 15 LUW W5AM OHLA0687 +0 ˚C 260 ˚C -5 ˚C 245 ˚C ±5 ˚C +5 ˚C 235 ˚C -0 ˚ min ...

Page 16

... Forward Voltage Group Wavelength Group Brightness Group OHA12043 Label Direction of unreeling Gurtvorlauf: 400 mm Leader: 400 mm Gurtende: 160 mm Trailer: 160 1.5 + 0.1 1.75 ± 0.1 (0.059 + 0.004) (0.069 ± 0.004) LUW W5AM OHAY0324 F 11.5 ± 0.1 (0.453 ± 0.004 max 30.4 (1.197) ...

Page 17

... WET units bake 15% necessary if units, examine wet, If units bake 10% necessary if units, wet, examine If dry. adequately desiccant still change parts 5% wet, If MIL-I-8835 Indicator Humidity Desiccant Barcode label 17 Humidity indicator Barcode label OHA00539 Barcode label Packing Sealing label LUW W5AM OHA02044 ...

Page 18

... As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. 2008-08-26 18 LUW W5AM Date of change 2008-02-27 2008-08-05 2008-08-12 ...

Page 19

... Components used in life-support devices or systems must be expressly authorized for such purpose! Critical 9) page 20 components may only be used in life-support devices or systems OSRAM OS. 2008-08- page 20 with the express written approval of 19 LUW W5AM ...

Page 20

... Life support devices or systems are intended ( implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail reasonable to assume that the health and the life of the user may be endangered. 20 LUW W5AM figures. These do not If requested, e.g. because ...

Related keywords