LUW W5PM-KYKZ-5P7R-Z OSRAM Opto Semiconductors Inc, LUW W5PM-KYKZ-5P7R-Z Datasheet

no-image

LUW W5PM-KYKZ-5P7R-Z

Manufacturer Part Number
LUW W5PM-KYKZ-5P7R-Z
Description
LED GOLD DRAGON OVAL WHT SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
Golden DRAGON® Plusr

Specifications of LUW W5PM-KYKZ-5P7R-Z

Color
White, Cool
Current - Test
350mA
Luminous Flux @ Current - Test
97lm
Current - Max
1A
Lumens @ Current - Max
216lm
Lumens/watt @ Current - Test
87lm/W
Voltage - Forward (vf) Typ
3.2V
Wavelength
6500K
Lens Style/size
Rectangle with Domed Top
Viewing Angle
70°, 120°
Mounting Type
Surface Mount
Package / Case
2-SMD, Gull Wing
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q65110A9010
Golden DRAGON oval Plus
Lead (Pb) Free Product - RoHS Compliant
LUW W5PM
Released
Besondere Merkmale
• Gehäusetyp: weißes SMD Gehäuse mit klarer
• Typischer Lichtstrom: 106 lm bei 350 mA bis
• Besonderheit des Bauteils: hocheffiziente
• Farbort: x = 0,31, y = 0,32 nach
• typische Farbtemperatur: 6500 K
• Abstrahlwinkel: Horizontal 120°, Vertikal 70°
• Technologie: ThinGaN
• optischer Wirkungsgrad: 134 lm/W bei
• Gruppierungsparameter: Lichtstrom, Farbort
• Verarbeitungsmethode: für
• Lötmethode: Reflow Löten
• Vorbehandlung: nach JEDEC Level 4
• Gurtung: 24-mm Gurt mit 200/Rolle, ø180 mm
• ESD-Festigkeit: ESD-sicher bis 8 kV nach
• Erweiterte Korrosionsfestigkeit:
Anwendungen
• Straßen- und Tunnelbeleuchtung, Beleuchtung für
• Ersatz für Leuchtstoffröhren, Gebäudeinnenbe-
2010-04-13
Silikonlinse
zu 249 lm bei 1 A
Lichtquelle bei geringem Platzbedarf
CIE 1931 (weiß)
100 mA
SMT-Bestücktechniken geeignet
oder 700/Rolle, ø330 mm
JESD22-A114-D
Details siehe Seite 11
Parkplätze, Fußgängerzonen, öffentliche Plätze
und Tankstellen, Flutlicht
leuchtung beispielsweise für Treppenhäuser, Ge-
schäfte und Büros.
1
Features
• package: white SMD package with clear
• typical Luminous Flux: 106 lm at 350 mA up
• feature of the device: high efficient lightsource
• color coordinates: x = 0.31, y = 0.32 acc. to
• typ. color temperature: 6500 K
• viewing angle: horizontal 120°, vertical 70°
• technology: ThinGaN
• optical efficiency: 134 lm/W at 100 mA
• grouping parameter: luminous flux,
• assembly methods: suitable for
• soldering methods: reflow soldering
• preconditioning: acc. to JEDEC Level 4
• taping: 24 mm tape with 180/reel, ø200 mm or
• ESD-withstand voltage: up to 8 kV acc. to
• Superior Corrosion Robustness:
Applications
• Outdoor lighting: streets, tunnels, parking lots,
• Linear indoor applications: fluorescent
silicone lens
to 249 lm at 1 A
at low space
CIE 1931 (white)
color coordinates
SMT assembly methods
700/reel, ø330 mm
JESD22-A114-D
details see page 11
pedestrian areas, public places, petrol stations,
flood light
replacement, floor lighting, retail/shop and office
lighting

Related parts for LUW W5PM-KYKZ-5P7R-Z

LUW W5PM-KYKZ-5P7R-Z Summary of contents

Page 1

... Golden DRAGON oval Plus Lead (Pb) Free Product - RoHS Compliant LUW W5PM Released Besondere Merkmale • Gehäusetyp: weißes SMD Gehäuse mit klarer Silikonlinse • Typischer Lichtstrom: 106 lm bei 350 mA bis zu 249 lm bei 1 A • Besonderheit des Bauteils: hocheffiziente Lichtquelle bei geringem Platzbedarf • ...

Page 2

... The above Type Numbers represent the order groups which include only a few brightness groups (see page 6 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LUW W5PM-KYLX-6P7R means that only one group KY will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. ...

Page 3

... Exemplary median lifetime for 2010-04-13 Symbol Symbol stg (min (max 175°C beträgt 100h 175°C is 100h LUW W5PM Wert Einheit Value Unit – 40 … + 125 °C – 40 … + 125 °C 135 °C 175* °C 100 mA 1000 mA 2500 mA not designed for V reverse operation ...

Page 4

... Seite 19 (typ page 19 ϕ (Vollwinkel)(typ (min (typ (max (max.) R (typ (max LUW W5PM Wert Einheit Value Unit 0.31 – 0.32 – vertical 70 Grad horizontal 120 deg. 2.7 V 3.2 V 3.7 V not designed for μ reverse operation A K/W 6.5 K/W 11* ...

Page 5

... Gruppe Cx Group 5R 0.289 0.287 0.304 0.305 6R 0.305 0.304 0.317 0.317 7R 0.317 0.322 0.330 0.334 LUW W5PM OHA03489 Cy 0.291 0.296 0.329 0.322 0.322 0.329 0.356 0.346 0.356 0.365 0.373 0.365 ...

Page 6

... Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Helligkeitsgruppe enthalten. Note: No packing unit / tape ever contains more than one brightness group. 2010-04-13 1) Seite 19 Lichtstrom 1) page 19 Luminous Flux Φ (mlm) V 82.000 ... 97.000 97.000 ...112.000 112.000 ...130.000 Farbortgruppe Chromaticity Coordinate Group 6P 6 LUW W5PM ...

Page 7

... Seite 19 2) page 19 500 550 30˚ 20˚ 10˚ 0˚ 1.0 0.8 0.6 0.4 0.2 0 0.6 0.4 0˚ λ 600 650 700 horizontal vertical 20˚ 40˚ 60˚ 80˚ 100˚ LUW W5PM OHL13926 nm 750 λ OHL04225 120˚ ...

Page 8

... Relative Lichtstrom Relative Luminous Flux Φ / Φ V OHL04196 Φ 3.3 3 page 19 OHL04427 Cx Cy 600 mA 1000 Seite 19 2) page (350 mA ° 2.5 Φ V (350 mA) V 2.0 1.5 1.0 0 200 400 600 LUW W5PM OHL04426 mA 1000 I F ...

Page 9

... Seite 19 Relative Lichtstrom Relative Luminous Flux Φ 350 OHL04428 ˚C 120 page 19 OHL04430 Cx Cy ˚C 120 Seite 19 2) page 19 / Φ (25 ° 350 1.2 Φ V Φ (25 ˚C) V 0.8 0.6 0.4 0.2 0 -40 - LUW W5PM OHL04429 ˚C 120 T j ...

Page 10

... DRAGON Product Family“ 80 100 ˚C 130 Zulässige Impulsbelastbarkeit F p Permissible Pulse Handling Capability Duty cycle = 25 °C S OHL04374 parameter ° 2.4 2.2 2 0.005 1.8 0.01 0.02 1.6 0.05 0.1 0.2 1.4 0.5 1 1.2 1.0 0 LUW W5PM OHL04374 ...

Page 11

... Note: LED is protected by ESD device which is connected in parallel to LED-Chip. Korrosionsfestigkeit besser als EN 60068-2-60 (method 4): mit erweitertem Korrosionstest: 40°C / 90%rh / 15ppm H Corrosion robustness better than EN 60068-2-60 (method 4): with enhanced corrosion test: 40°C / 90%rh / 15ppm H Kathodenkennung: Cathode mark: Gewicht / Approx. weight: 2010-04- 336h 336h 2 Markierung mark 400 mg 11 LUW W5PM ...

Page 12

... Gurtung / Polarität und Lage Method of Taping / Polarity and Orientation 2010-04-13 5) Seite 19 Verpackungseinheit 200/Rolle, ø180 mm oder 700/Rolle, ø330 mm 5) page 19 Packing unit 200/reel, ø180 mm or 700/Rolle, ø330 mm 12 LUW W5PM ...

Page 13

... Lötstellen Thermisch optimiertes PCB 3 solder points Thermal enhanced PCB 11.6 (0.457) 1.6 (0.063) 12.0 (0.472) 11.6 (0.457) Kupfer Copper 13 LUW W5PM Reflow Löten Reflow Soldering ø4.0 (0.157) Heatsink attach Lötstopplack Solder resist Lötpasten Schablone Solder paste stencil 1.6 (0.063) Freies Kupfer 1 (0 ...

Page 14

... Vorbehandlung nach JEDEC Level 4 Preconditioning acc. to JEDEC Level 4 (nach J-STD-020C) (acc. to J-STD-020C) Maximum Solder Profile Recommended Solder Profile Minimum Solder Profile 120 s max 100 150 14 LUW W5PM OHLA0687 +0 ˚C 260 ˚C -5 ˚C 245 ˚C ±5 ˚C +5 ˚C 235 ˚C -0 ˚ min ...

Page 15

... Forward Voltage Group Wavelength Group Brightness Group OHA12043 Label Direction of unreeling Gurtvorlauf: 400 mm Leader: 400 mm Gurtende: 160 mm Trailer: 160 1.5 + 0.1 1.75 ± 0.1 (0.059 + 0.004) (0.069 ± 0.004) LUW W5PM OHAY0324 F 11.5 ± 0.1 (0.453 ± 0.004 max 30.4 (1.197) 30.4 (1.197) ...

Page 16

... MIL-I-8835 Indicator Humidity Desiccant Barcode label Länge / length ± ± 200 5 (7,874 0,1968) ± ± 352 5 (13,858 0,1968) 16 Humidity indicator Barcode label OHA00539 Barcode label Packing Sealing label Höhe / height ± ± (1,65 0,1968) ± ± (1,65 0,1968) LUW W5PM OHA02044 ...

Page 17

... As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. 2010-04-13 17 LUW W5PM Date of change 2009-05-06 2009-07-20 2009-10-26 ...

Page 18

... Components used in life-support devices or systems must be expressly authorized for such purpose! Critical 6) page 19 components may only be used in life-support devices or systems OSRAM OS. 2010-04-13 7) page 19 with the express written approval of 18 LUW W5PM ...

Page 19

... Life support devices or systems are intended ( implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail reasonable to assume that the health and the life of the user may be endangered. LUW W5PM not necessarily of technical expanded ...

Related keywords